Installation Guide / SolarRoof Terracotta Tile
1Code-Compliant Planning and Installation Guide V 1.0 - Complying with AS/NZS1170.2-2011 AMDT 2-2016
Introduction
Using only PV-ezRack® parts and installer-supplied
parts as specified by the PV-ezRack® project plan.
(substitution of parts may void the warranty and
invalidate the letter of certification).
Recycling: Recycle: according to the local relative
statute.
Removal: Reverse installation process.
Ensure that there are no less than two professionals
working on panel installation.
Ensure the installation of related electrical equipment
is performed by licenced electricians.
Ensuring safe installation of all electrical aspects of
the PV array. This includes adequate earth bonding of
the PV array and PV-ezRack® SolarRoof components
as required inAS/NZS 5033: 2021.
Ensuring that the roof, its rafters/purlins, connections,
and other structural support members can support
the array under building live load conditions.
Ensuring that screws to fix interfaces have adequate
pull-out strength and shear capacities as installed.
Maintaining the waterproof integrity of the roof,
including selection of appropriate flashing.
Verifying the compatibility of the installation
considering preventing electrochemical corrosion
between dissimilar metals. This may occur between
structures and the building and between structures,
fasteners and PV modules, as detailed in AS/NZS
5033: 2021;
Verifying atmospheric corrosivity zone of installation
site by referring to AS 4312-2008 or consulting local
construction business to determine appropriate
products and installations.products and installations.
•
•
•
•
•
•
•
•
•
•
•
The Clenergy PV-ezRack® SolarRoof has been
developed as a universal PV-mounting system for
roof-mounting on pitched and flat roofs. The use of
patented aluminium base rails, Z-Module technology
and telescopic mounting technology eliminates custom
cutting and enables fast installation.
Please review this manual thoroughly before installing
PV-ezRack® SolarRoof. This manual provides:
1) Supporting documentation for building permit
applications relating to PV-ezRack® SolarRoof Universal
PV Module Mounting System.
2) Planning and installation instructions.
Complying with all applicable local or national
building codes, including any that may supersede this
manual.
Ensuring that PV-ezRack® and other products are
appropriate for the particular installation and the
installation environment.
•
•
The installer is solely responsible for:
The PV-ezRack® SolarRoof parts, when installed
in accordance with this guide, will be structurally
sound and will meet the AS/NZS1170.2:2011 Amdt
2- 2016 standard. During installation, and especially
when working on the roof, please comply with
the appropriate Occupational Health and Safety
regulations. Please also pay attention to any other
relevant State or Federal regulations. Please check
that you are using the latest version of the Installation
Manual, which you can do by contacting Clenergy
Australia via email on tech@clenergy.com.au or
contacting your local distributor in Australia.
Product Warranty:
Please refer PV-ezRack® Product Warranty on our
website.
List of contents
Introduction
Planning
Tools & Components
System Overview
Installation Instructions
Certification
01
02
06
08
10
18