manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Clevetronics
  6. •
  7. Lighting Equipment
  8. •
  9. Clevetronics LP CBS2LEDS-DIF Series User manual

Clevetronics LP CBS2LEDS-DIF Series User manual

1948769 V1.1 July 2019
Clevertest and Clevertest Plus
Refer to the supplementary operation guide supplied with the Product.
After Power ON, the Status LED on a Clevertest Plus enabled fitting will display a rapid Green or Red
flashing for a period up to 2 minutes.
Zoneworks and DATA Monitored Options
LP battens with part numbers –ZW and -DATA are fitted with Zoneworks communications modules
(nodes). These fittings are monitored using either Powerline Carrier Technology that utilising the power
cable to provide data communication or a dedicated data cable to/from data routers installed on a
dedicated data trunk connected to a central Server (can also be connected via Ethernet/Internet/Fibre).
Zoneworks software on the server is used to monitor, coordinate testing and collate test data from each
batten. Zoneworks Battens can be commissioned by a single push of the test switch or scanning of the
supplied barcode. The LED Test Switch indicator provides a multifunction indication of the status of the
Fittings during testing and normal operation:
State
LED Operation
Commissioned
LED on Solid (Green)
Un-commissioned
LED flashes at 0.5Hz (0.5s Green, 0.5s Yellow)
Emergency Light Test In Progress
LED flashes at 3s On (Yellow) & 0.5s Off
In the case of the DATA version a 2-way “figure 8” cable and terminal block facilitates the connection to
the DATA network via a multi-drop bus (daisy chain connection). For further information of installation of
a Zoneworks LW system, please refer to the Zoneworks Users Guide and Commissioning Guide (incl.
DATA version)
DALI EM Option
LP battens with part numbers -DALI are fitted with DALI modules (nodes) that facilitate connection and
integration to 3rd Party Lighting Control Systems. Before installing the -DALI batten, please confirm that
the Lighting Control System has the capability to monitor DALI Emergency Luminaires. The batten will
be addressed and configured into the control system by the Lighting Control System Commissioning
Technicians and not Clevertronics.
State
LED Operation
Commissioned/ Un-commissioned
LED on Solid (Green)
Emergency Light Test in progress
LED flashes at 1s On (Yellow) & 1s Off
“IDENTIFY COMMAND”
Fitting goes into emergency mode for 10 seconds
A 2-way “figure 8” cable and terminal block facilitates the connection to the DALI network OR a 5/6way
“structured wiring system” lead and plug facilitating the power and DALI connection. DALI connections
are marked as Da Da.
LP™ Sustained Emergency LED Battens
Installation & Maintenance Instruction Leaflet
Designed in Australia to comply with the
requirements of AS2293.3: 2005 and AS/NZS
CISPR15: 2011.
NOTE: Standard product codes with this symbol are
enabled with Clevertest Plus capability. Please refer to
the operation guide supplied with the product for details.
Victoria (Head Office & Manufacturing)
195 Chesterville Rd Moorabbin VIC 3189
Phone: +61 3 9559 2700
Fax: +61 3 9559 2799
News South Wales
Phone: +61 2 8805 6400
Fax: +61 2 8805 6444
Queensland
Phone: +61 7 3442 9700
Fax: +61 7 3442 9777
South Australia/Northern Territory
Phone: +61 8 8301 8800
Fax: +61 8 8351 8286
Western Australia
Phone: +61 8 9248 3720
Fax: +61 8 9248 3725
New Zealand
Phone: +64 800 548 448
Models: CBS2LEDS-DIF-yy-zz
Testing:
Manual Test
yy = Blank
Options:
Zoneworks
yy = ZW
On/Off Sensor Control
zz=MS
Zoneworks DATA
yy = DATA
DALI Driver
zz=DD
DALI Compatible
yy = DALI
Clevertest
yy = CT (NOTE: Products supplied with the Clevertest Plus Symbol are
activated with Clevertest PLUS capability. Please refer to the operation guide
supplied with the product for details).
Spare Parts:
1550050
BATT: LP 3.2V 3200mAh 70mm lead,no BRKT.
1100634
LP, Emergency LED PCA
CLIFE-CKIT-NP
Lifelight, Control Only, LP
8002695
PCA: LED Strip 8S6P, ALS-13-840-0-02
1330029
LED Driver - 40W, 500-1050mA, 15-50V
1330038
LED DALI Driver - 25W, 350-1050mA, 20-50V (-DD Option)
1190117
SENSOR:Microwave Motion, IP20, MC602S
Important:
It is illegalfor anyone, except for a licensed electrician toinstall ormaintain this product. Before installation,
ensure that the electricity supply has been switched off and isolated. Installation must be carried out in
accordance with the relevant Australian and International Standards.
1948769 V1.1 July 2019
Installation:
This LP Emergency batten can be wall or ceiling mounted.
•Refer Images below for the mounting hole, cable access and other dimensions.
•Remove the diffuser.
•Remove the cover plate and disconnect the LED strip connector. Unhook the lanyard
•Position the batten in the desired location.
•Mark out the fixing points on the mounting surface.
•Install appropriate fixing hardware.
•Route power supply cables through the access hole as the rear of the fitting or the ends if using
surface conduit (punch out the knock-outs in the plastic end caps)
•Fasten the batten to the surface.
•Terminate the supply cable to the terminals marked AEM, N, ASW and E (240V AC/50Hz)
•Attach the cover plate to lanyard, Re-connect the LED strip connector and Re-attach the cover
plate onto the body of the batten.
•Re-install the diffuser
•If the CTP capabilities are activated, please affix the CTP Status Label to a visible surface.
Networking:
When installing the LP Sustained Emergency Battens on a monitored network, (ZONEWORKS, DATA,
DALI) simply insert the relevant Smart Node PCA.
Images and Dimensions:
Testing:
When the LP batten unit is connected to the un-switched active, it must be allowed to charge the battery
for at least 24 hours. The emergency lamp only illuminates during a power fail. Conduct the following
tests:
•The emergency lamp must illuminate for at least 2 hours after disconnection from the mains. The
results of all tests are required to be recorded in a service logbook, which is to be kept on-site at all
times. If the unit fails to illuminate for the requisite time, remedial action must be taken to repair the
situation and once completed, the unit must pass a subsequent test.
•Press and hold Test Button or switch Off Mains Supply, check that the emergency lamp is On.
•Release the Test Button or Switch On Mains Supply, check that the emergency lamp is Off (Non-
maintained operation).
Below are a list of common problems and their possible causes:
Fault: The Green LED indicator is not illuminated.
Check: A.C. is connected and is turned on.
Battery is connected.
Test Switch for damage.
Fault: Lamp does not illuminate in emergency mode.
Check: A.C. is connected.
Lamp is correctly inserted.
Battery is connected
Fault: Lamp illuminates in emergency mode, but only stays on for a short period.
Check: Battery has been allowed to charge for at least 24 hours.
Battery for damage.
Rated Emergency Lumen Output in accordance with AS2293.1 (refer
to spacing tables for installation positions):
Refer to the Technical Label for classification information.
Caution:
On many building sites, power circuits may be cut off in an uncontrolled and repetitive basis during
construction. As a result, any LP battens, on these circuits, will have their batteries discharged or
“cycled”. The Li-ion battery in the LP batten has been selected to give excellent long-life performance in
a controlled IEC 60598-2-22 testing environment. Excessive battery cycling will reduce through-life
performance and may lead to premature battery failure. Battery warranty claims, as a result of such
abuse, are specifically EXCLUDED from Clevertronics warranty terms.
Warranty:
For Product Warranty information and Terms and Conditions of Sales please refer to our website
http://clevertronics.com.au/terms-conditions-sale-australia-nz/

Other Clevetronics Lighting Equipment manuals

Clevetronics L10 LVELED Series Installation and operating instructions

Clevetronics

Clevetronics L10 LVELED Series Installation and operating instructions

Clevetronics L10 LUBPRO-SM-UPS User manual

Clevetronics

Clevetronics L10 LUBPRO-SM-UPS User manual

Clevetronics L10 LUBPRO UPS Series User manual

Clevetronics

Clevetronics L10 LUBPRO UPS Series User manual

Clevetronics L10 LUBPRO Series Installation and operating instructions

Clevetronics

Clevetronics L10 LUBPRO Series Installation and operating instructions

Clevetronics CleverEVAC CLP Cleverfit Pro Dynamic Green User manual

Clevetronics

Clevetronics CleverEVAC CLP Cleverfit Pro Dynamic Green User manual

Clevetronics L10 LVELED Series User manual

Clevetronics

Clevetronics L10 LVELED Series User manual

Popular Lighting Equipment manuals by other brands

TECshow Powerbox user manual

TECshow

TECshow Powerbox user manual

Doughboy Stair Waves Owner's guide and warranty

Doughboy

Doughboy Stair Waves Owner's guide and warranty

Inspire Lakko Assembly, Use, Maintenance Manual

Inspire

Inspire Lakko Assembly, Use, Maintenance Manual

Leviton N7008 user guide

Leviton

Leviton N7008 user guide

Nanoleaf Shapes Hexagons Smarter Kit quick start guide

Nanoleaf

Nanoleaf Shapes Hexagons Smarter Kit quick start guide

MiaLuz LM10220AC3 manual

MiaLuz

MiaLuz LM10220AC3 manual

Harbor Freight Tools luminarEVERYDAY 59249 Owner's manual & safety instructions

Harbor Freight Tools

Harbor Freight Tools luminarEVERYDAY 59249 Owner's manual & safety instructions

Ledj Event Spot Bar RGBW user manual

Ledj

Ledj Event Spot Bar RGBW user manual

BARRON EXITRONIX LED-51 Series installation instructions

BARRON

BARRON EXITRONIX LED-51 Series installation instructions

Sunricher SR-ZV9001T-CCT-EU instructions

Sunricher

Sunricher SR-ZV9001T-CCT-EU instructions

ArtFox Alpha Wash 108 user manual

ArtFox

ArtFox Alpha Wash 108 user manual

Quoizel NAO1507EK installation guide

Quoizel

Quoizel NAO1507EK installation guide

Cooper Lighting Halo Lazer LZR330 Specification sheet

Cooper Lighting

Cooper Lighting Halo Lazer LZR330 Specification sheet

Eterna MSCSLEDCR installation instructions

Eterna

Eterna MSCSLEDCR installation instructions

Prilux Hexagon ZENIT instruction manual

Prilux

Prilux Hexagon ZENIT instruction manual

Seko PoolDose Single instruction manual

Seko

Seko PoolDose Single instruction manual

Francis Searchlights L480RC User and installation manual

Francis Searchlights

Francis Searchlights L480RC User and installation manual

ERA Lighting 280W Beam Spot Wash user manual

ERA Lighting

ERA Lighting 280W Beam Spot Wash user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.