ComfortHeat C 511T User manual

Programmable thermostat C 511T with
oor temperature sensor
C511T

Programmable thermostat C 511T with
oor temperature sensor EN
2
© 2019 Comfort Heat Ltd.

2
Thermostat C 511T has a CE marking which satisfies European
Council directives and applied standards EMC: EN 61000-6-1:
2001, EN 61000-6-3: 2001, LVD: EN 60730-1, EN 60730-2-9.
The product is a Class II device (enhanced insulation) and must be
connected to the following leads:
Term. 1: Neutral (N)
Term. 2: Live (L) 230 V±10%, 50/60 Hz
Term. 3 - 4: Load, max. 16A/ 3600W
Term. X: Do not connect
Term. 5-6: External floor sensor
1. THERMOSTAT USE INSTRUCTION
The programmable thermostat C 511T is specially developed to
provide comfort heating using as little energy as possible. C 511T
is used to control the floor heating but can equally be used with all
types of heating systems.
The thermostat C 511T can switch your heating system on at
pre-determined time on different days of the week. For each day
of the week you can set individual temperatures for 4 different
periods, called events. Lowering the temperature when the home
is unoccupied will reduce your energy costs without reducing
comfort.
The thermostat C 511T comes with a default factory schedule
3

4
suitable for most installations. The thermostat operates in
compliance with this default programme unless you set your
own weekly schedule. The thermostat has a reset button marked
R allowing you to reset the thermostat back to default factory
settings.
The thermostat C 511T features an adaptive function that
automatically changes the start time of heating periods so as to
ensure that the required temperature is reached at the set time.
After 3 days the adaptive function will have calculated when the
heating must be switched on.
2. FLOOR TEMPERATURE SENSOR INSTALLATION
Floor temperature sensor NTC is in protection class IP67 and
complies with applied standards EN 61386-1.
The temperature sensor is mounted in the oor as shown in Pic. 1.
The resistance of the oor temperature sensor is shown in Pic. 2.
Cut a groove in the oor and the wall to the thermostat junction
box. Put the sensor pipe into the groove and seal its end with
aluminium foil or a special metal cap to avoid the concrete
entering the pipe. Bend the pipe (10-16mm) between the wall and
the oor with a large bending radius (8 diameters). The end of the

5
pipe should be placed between the cable loops (under the heating
mat) but not closer than 30cm from the edge of heating area.
Insert the sensor into the pipe. This allows the sensor to be easily
replaced if necessary. The sensor cable can be extended by up to
50m by means of a separate cable. Connect the oor temperature
sensor to the thermostat as shown in the wiring diagram (Pic 4).
Picture 1 Picture 2

3. THERMOSTAT INSTALLATION
• Slide the power button down to OFF “0”.
• Release the front cover ONLY by inserting a small
screwdriver into the hole on either side of the thermostat
(Pic. 3). DO NOT open the thermostat by releasing the four
xing clips on the back.
• Make electrical connections according to the diagram (Pic.
4.)
• Mount the thermostat in the wall socket. Fit the frame and
carefully press the cover onto the thermostat. Ensure that
both the power slide button on the cover and the power
switch pin are down.
• Prepare thermostat for use.
6
Picture 3 Picture 4

4. FIRST TIME SETTINGS
The rst time the thermostat is connected, push the power slide
button to ON “I”. Language, time and date must be set. The menu
will automatically guide you through the process.
• Choose your language with the Up and Down buttons and
conrm with the OK button.
• Set the actual hour and press the OK button. Then set the
minutes. Press OK.
• Set the actual date: year, month and day. Conrm the
settings with the OK button.
The thermostat is now ready for use and will control your heating
according to the pre-programmed 4-event schedule, see chapter
7 (4- event settings).
5. GENERAL OPERATION
The power interrupter button allows you to turn the thermostat
ON “I” and OFF “0” by sliding the button up and down. When the
thermostat is switched o “0”, the relay disengages. All settings,
including time and date, will be remembered.
7

8
The thermostat is intuitively operated using the navigation
buttons. The function of each button is indicated above the button
on the display.
Back and Exit
In various parts of the menus and sub-menus you will nd the
Back and Exit items. Use Back to return to the last step. Use Exit to
return to initial display.
6. OPERATION MODES
The thermostat C 511T has 3 dierent modes of temperature
control:

9
Auto mode.
Select Auto if you want the temperature to be
controlled automatically via the 4-event schedule.
Manual mode.
Select Manual to cancel the programmed 4-event
schedule and to set the required temperature
manually. For example, during the holiday you may
want to adjust the temperature to 5°C for frost
protection while you are away. Press Manual, conrm
with OK and choose the required temperature.
Comfort mode.
Select Comfort to set a temporary comfort tempera-
ture for a single event. Press Comfort, conrm with OK
and choose the required temperature. Then enter the
required duration of comfort mode. After the set time
has elapsed, the thermostat will automatically revert to
Auto mode. Please note that Comfort mode is a tempo-
rary manual setting that will be automatically cancelled
by the next event in the programmed 4-event schedule.
7. THERMOSTAT SETUP MENU
4-event settings allow you to have the temperature controlled

10
automatically in accordance with a programme of your choice. You
can select temperature settings for 4 dierent events during the day:
When you wake up in the morning
When you away at work
When you come home
When you go to bed at night
The thermostat is pre-programmed with a 4-event schedule for easy
and economic heating control, see the chapter 8 (Factory settings). The
schedule can be easily changed in the following way:
1.Press the OK button to activate the 4-event
settings display.
2.Choose the days for which you want to
change the settings, Mon-Fri or Sat-Sun using
the up or down button. Press OK.
3.Choose one of 4-events, conrm with OK.
4.Now select the time and temperature for that
11

11
daily event in the programme. Set the start time
using the UP or DOWN button, conrm with OK.
Set the temperature using the UP or DOWN
button for this event and conrm with OK.
5.After setting the required events, select Exit in
the menu to return to the initial display.
User settings.
In the user settings menu you can change the following items:
Time and date. Press OK and set the actual
time in hours and minutes. The date will then be
displayed. Set the date and conrm with OK.
Child lock. Allows you to lock the thermostat
settings, e.g. in public or other places where
you do not want the settings be changed. Press
OK and set the child lock to ON using the down
button. Conrm with OK. The child lock can be
unlocked by pressing both the Comfort and
Manual buttons simultaneously for 5 seconds.
Display settings. Allow you to select what is
shown on the initial display.
Time/day: Shows the actual time and day at the
top of the display.

12
Set temp.: Shows the current temperature setting.
Act. temp.: Shows the actual measured
temperature.
Scr. saver: Switches o the display after 30 seconds
if no button is pressed. Any subsequent press of
a button reactivates the display. The thermostat
remains on and runs the selected programme.
Press the OK button to select or deselect the display options. Then
select Exit in the menu to return to the initial display and view your
chosen settings.
4-event schedule. Allows you to choose the type
of weekly 4-event schedule you require.
5:2 : Monday to Friday with 4 events and
Saturday to Sunday with 2 events. Typically
used if you work from Monday to Friday.
6:1 : Monday to Saturday with 4 events and
Sunday with 2 events. Typically used if you work
from Monday to Saturday.
7:0 : Monday to Sunday with 4 individual events.
Allows you to choose individual programmes
for each of the 7 days of the week.
Select the required 4-event schedule and conrm
with OK. For instructions on programming the
time and temperature for the 4-event schedule, see
4-event settings.

13
Energy monitor. Allows you to view energy
consumption for the past 2 days, 30 days or
365 days. Press OK for the chosen period. The
value in percent (%) shows the relative amount
of time the heating has been on. The following
gure is the cost for the selected period. To
ensure correct calculation, check the settings for
currency, price per kWh and load.
Currency: Press OK and choose the required
currency. Conrm with OK.
Cost/unit: Press OK and set the actual cost of
electricity. The cost must be entered per kWh.
Press OK.
Load: Press OK and enter the connected
heating power. The value must be in watt (W).
Press OK. Leave the menu by pressing Exit.
Engineer settings. The Engineer settings menu contains the
following options:
If the actual measured
temperature does not corresponding to the
thermostat value, you can adjust the thermostat
by osetting the temperature. Press OK and
enter the value of the measured temperature.
Conrm with OK.

14
Adaptive function. Ensures that the required
temperature has already been reached when
you get up in the morning or come home from
work. After just a few days, the adaptive function
will have automatically calculated when the
heating must be turned on. Press OK and set the
function to ON. Conrm with OK.
Application. Shows that the oor regulation
is used. The thermostat regulates oor
temperature only. A oor sensor must be
connected.
Temperature scale. Allows you to set the
temperature range within which the thermostat
can be set. It is then only possible to set a
temperature within this range in Auto, Comfort
and Manual modes. Press OK to highlight Min
temperature. Use the up or down button to
select the minimum permissible temperature.
Press OK and select the maximum permissible
temperature. Conrm the settings with OK.
Language. Allows the language used on the
display to be changed. Press OK and select the
required language. Conrm with OK.

15
Factory reset. Allows factory settings to be
restored. Your personal settings will be lost,
see chapter 8 (Factory settings). Press OK and
choose Reset in the menu. Conrm with OK.
Information. Displays the thermostat
software version. Leave the menu by pressing
EXIT.
8. FACTORY SETTINGS
Day 1-5
Event Time With oor sensor
Day 06:00-08:00 25°C
Out 08:00-16:00 20°C
Home 16:00-22:30 25°C
Night 22:30-06:00 20°C
Day 6-7
Day 08:00-23:00 25°C
Night 23:00-08:00 20°C

16
9. ERROR CODES
If a fault or error occurs, the thermostat will display an error code
as follows:
E0 = Internal failure. The thermostat is defective. Replace thermostat.
E2 = External sensor short-circuit or disconnected.
10. WARRANTY
Warranty period for thermostat C 511T is 36 months. Warranty is
valid if the following documents are presented:
1. Warranty coupon (lled in correctly);
2. Document of purchase: invoice or receipt;
3. The obligation of Comfort Heat will be repair or supply a
new unit, free of charge to the customer, without secondary
charges linked to repairing the unit.
The Comfort Heat warranty does not cover installation made by
unauthorised electricians, or faults caused by incorrect designs
supplied by others, misuse, damage caused by others, or incorrect
installation or any subsequent damage that may occur. If Comfort
Heat is required to inspect or repair any defects caused by any of the
above, then all work will be fully chargeable.
The Comfort Heat warranty is void, if payment for the equipment
is in default.

16 17
Programuojamas termostatas C 511T
su grindų temperatūros jutikliu LT
© 2019 Comfort Heat Ltd.

Termostatas C 511T atitinka šiuos Europos Sąjungos direktyvų,
numatančių „CE” ženklinimą, standartus: EMC: EN 61000-6-1:
2001, EN 61000-6-3: 2001, LVD: EN 60730-1, EN 60730-2-9.
Šis termostatas priskiriamas II elektrotechninių įrenginių klasei ir
turi būti jungiamas prie elektros tinklo taip:
1 gnybtas: nulis (N)
2 gnybtas: fazė (L) 230 V±10%, 50/60 Hz
3-4 gnybtai: šildymo kabelis arba kilimėlis, maksimali apkrova
3600W, maksimali srovė 16A.
X gnybtas: Nejungti
5-6 gnybtai: grindų temperatūros daviklis
Programuojamas termostatas C 511T skirtas elektrinei grindų
šildymo sistemai valdyti ir montuojamas į potinkinę dėžutę.
Termostatas C 511T turi grindų temperatūros jutiklį ir valdo grindų
temperatūrą. Termostatas C 511T gali būti naudojamas ir kitų
šildymo sistemų valdymui.
Termostatas C 511T gali įjungti šildymo sistemą skirtingomis
savaitės dienomis pagal iš anksto gamykloje nustatytą laiką.
Galima nusistatyti individualią temperatūrą kiekvie žeminimas,
kai esate išvykę iš namų, leis sumažinti energijos sąnaudas,
neprarandant komforto.
18

19
Gamyklos nustatyti temperatūros režimai daugeliu atvejų pilnai
tenkina vartotojo poreikius, todėl kol jūs nepakeisite nustatytų
parametrų, termostatas C 511T valdys šildymo sistemą pagal
gamyklinius nustatymus. Norėdami grįžti iš individualių nustatymų
į gamyklinius, paspauskite mygtuką R.
Termostatas C 511T turi prisitaikymo funkciją. Tai reiškia,
kad termostatas (remiantis paskutinių 3 parų duomenimis)
automatiškai keičia šildymo sistemos įsijungimo laiką, užtikrinant,
kad reikiama temperatūra bus pasiekta nurodytu laiku.
2.
Grindų temperatūros daviklis NTC priklauso IP67 apsaugos klasei
ir atitinka Europos Sąjungos direktyvų standartą EN 61386-1.
Temperatūros jutiklis montuojamas į grindis, kaip parodyta pav. 1.
Grindų temperatūros daviklio varžos priklausomybė nuo
temperatūros nurodyta pav. 2.
Išpjaukite arba iškalkite griovelį temperatūros jutiklio vamzdeliui
grindyse ir sienoje iki termostato potinkinės dėžutės. Įdėkite
temperatūros jutiklio vamzdelį į griovelį ir užsandarinkite
vamzdelio galą, kad į jį nepatektų betono. Vamzdelio (16 mm)

20
lenkimo spindulys tarp sienos ir grindų turi būti apie 8 vamzdelio
diametrai. Jutiklio vamzdelio galas turi būti patalpintas po šildymo
kilimėliu, tarp šildymo kabelio vijų, bet ne arčiau kaip 30 cm
nuo šildomo ploto krašto. Įverkite grindų temperatūros jutiklį į
vamzdelį. Tokiu būdu užtikrinamas lengvas jutiklio pakeitimas,
esant reikalui. Grindų temperatūros jutiklio laidas gali būti
prailginamas iki 50 m, naudojant atskirą varinį 2x1,5 laidą.
Prijunkite grindų temperatūros jutiklį prie termostato taip, kaip
parodyta schemoje pav. 4.
Paveikslas 1 Paveikslas 2
Other manuals for C 511T
1
Table of contents
Languages:
Other ComfortHeat Thermostat manuals

ComfortHeat
ComfortHeat C 101 User manual

ComfortHeat
ComfortHeat C 101 User manual

ComfortHeat
ComfortHeat C 501 User manual

ComfortHeat
ComfortHeat MCD4 User manual

ComfortHeat
ComfortHeat MCC2-1991 User manual

ComfortHeat
ComfortHeat MCD5 -1999 User manual

ComfortHeat
ComfortHeat Comfort ECO User manual

ComfortHeat
ComfortHeat C 511T User manual

ComfortHeat
ComfortHeat Comfort Touch User manual

ComfortHeat
ComfortHeat Comfort Touch User manual