manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Commax
  6. •
  7. Door Lock
  8. •
  9. Commax CDL-200P User manual

Commax CDL-200P User manual

CDL-200P
USER MANUAL
* No unauthorized person should disassemble, repair or modify the device.
* This product is for indoor use.
* Please read the User Manual before useing product.
* Do not press the buttons with any sharp objects
* Change your access code from time to time for your safety.
* Do not impact the device.
* Be careful of leakage or rupture that may occur when inserting a battery in wrong direction.
* Prevent the device coming in contact with water
* when replacing a battery, change all the batteries with new alkaline batteries.
* Please wipe the product with soft, dry towels.
* Please keep product warranty card for after service.
* Do not use this product for other purposes than digital door lock function.
Products specifications and components
Outdoor Names and Functions
*The components of the product may change depending
on the installation environment.
This lock does not come with a physical key and
in the rare event of failure, may require the destruction
of the lock for removal and replacement.
Registration authentication setting
1. Enter password 2. Press [#] button twice,
press [8] button.
Registration
authentication
Mode on/off
1. If registration authentication mode is activated, first authentication by
existing password should be done for the next step.
* Registration authentication is not activated if factory setting.
* To deactivate registration authentication, repeat the same procedure
for activation
Reference
Open the door in outside
Method 1 Open the door by password
1. Enter password 2. Press [*]button
Touch the number
plate and enter your
password
Press the [*] button,
you will hear a
confirmaion tone and
then the door will open
COMMAX Co., Ltd.
Thank you for purchasing COMMAX products.
Please red this manual before use.
Commax is not responsible for any safety issues
due to abnormal operation of
the product
Safety Warning
These warning are to ensure the secure operation of the lock.
Carefully read the instructions below
How to register and change password
Be sure to register your password with the door open.
3. Enter new password
After entering the new password(4~12 digits),
press * button and the confirmation tone sounds
and registration is completed. Press the * button
once more to end registration.
1. If you register a new password, the existing password will be automatically
deleted.
2. Do not use consecutive numbers when registering your password.
Cautions
1. Press
[registration] button
2. Press [1]button in the number
plate of outdoor side
Beep
Open the battery cover and
press [registration]button
1. When adding the password, repeat the above item 3 before the key pad
turns off.
2. Up to 4 password can be registered
Reference
Indoor Names and Functions
9V emergency battery
(Separate purchase)
No Name Specifications
1 Battery cover This cover protects the batteries and the
registration button.
2 Indoor handle Used to open or close the door indoors.
3 Registration button(R) Used to register or change password or smart key
4 Mortise Closes or locks the door
5Dead bolt
(Square locking type) It locks the door
6 Latch bolt Stabilizes door on closing
7 Alkalina AA battery Power source thst operates the door lock
8Double lock button
(Close button) Cna be used to lock the door so that it can not
be opened from the outside.
Locking door from inside and outside
Indoor Outdoor
Press the [double lock] button
on the inside Touch the keypad
Internal double lock setting
Setting
How to release internally
It is a function that can not open a door with a password or a smart
key outside the door.
1. While the door is locked, press and hold the [double lock]
button for 3 seconds
If you press and hold the [DUAL LOCK] button for
3 seconds, the setting is completed with sound.
2. Press the [double lock] button
inside to dismiss double lock setting
1. Push the indoors handle
Deactivation from outdoor unit
1. Enter Password 2. Press [#], [9] button
Press [#] then press [9],
internal double lock is off
with beep sound
Multi-level volume control / Selectable silence function
Light-up buttons for visibility
High-voltage protection/Fire protection/Anti-hack system
Remote control using BLE, ZIGBEE
Durable Door lock
Metal body
Additional number entry for secure password
Multiple passwords can be registered
Emergency power function (9V battery)
Simple registration
Outbody Inbody Mortise & Stricker Screw Installation
instruction
User manual
8 Batteries Construction diagram 4 Smart key Outdoor shaft
Sort Specifications
Password 4-12 digits (Up to 4 can be registered)
Smart key It can register within 30
Rated voltage DC 6V LR6 1.5V AA sized alkaline batteries 4
Emergency power DC 9V Alkaline batteries 8 (Separate purchase)
Type of product
High temperature
sensing Temperature sensor type
Out body AL,ZN,ABS,PC
In body AL,ZN,ABS,PC
60℃ ± 10℃
Opening method
Fire-proof, Temperature-sensitive form, None-KEY, Primary keylock / F-T-NK-M)
Material
No Name Specifications
1 Number plate Enter the number when registering or changing password.
2 Battery warning light Turns on with an audible alarm at low voltage.
3 Outdoor handle It is Used to open or close doors from outdoors.
4Emergency power
terminal
In case the battery is completely discharged, you can use 9V
battery then, the power will be on.
5 Smart key input unit
It is the place where smart keys are recognized to open the
door. You can open the door by registering the smart key or
touching the registered smart key.
1. Press
[registration] button
2. Press [2]button in the number
plate of outdoor side
Beep
Open the battery cover and
press [registration]button
3. Contact smart key to smart key input unit
If you touch the smart key to be registered one by one,
you will hear a confirmation sound every time you touch it.
Registration is completed by clicking the [Registration]
button on the indoor side body.
1. When registering a new smart key, the existing smart key is automatically
deleted.
Reference
Cautions
1. When adding the smart key, please repeat the above item 3 before the
[Number plate lamp] turns off.
2. Up to 30 smart keys can be registered.
How to register smart key
How to delete smart key
2. Press [7]button in the number plate
3. Press [#] button
Press and hold the [#] button for 5 seconds to delete
the registered smart key.
1. Press
[registration] button
Beep
Open the battery cover and
press [registration]button
Open the door with smart key
1. Contact smart key to smart key input unit
Method 2
When the registered [Smart Key] is touched to the
smart key input part, a confirmation tone is heard
and it opens when you open the door.
Touch the number
plate and enter your
password
Touch the number
plate and enter your
password
Volume Adjustment
Deadbolt of indoor unit must be come out from mortise before setting
How to
1. Enter Password 2. Press [#] button
3. Press [3] or [6] to adjust volume
[3] for volume up
[6] for volume down
1. Available total 8 levels of volume sound
2. If sound pause mode, numbers are only flicking without sound
Reference
1.If no sound deactivation or door lock malfunction, product installed position
has to be adjusted. Please contact your local installer or service provider.
Caution
Battery Replacement Alert
1. Lifetime of battery can be varied according to manufacturers, date of production,
working condition. (Expected lifetime : 10 months assuming no wireless operation,
AA type alkaline 8ea, 10 times per one day use)
2. If battery liquid leaks out, product can be damaged. Regular checking is
recommended – every 6 months.
3. Battery lifetime might be shortened if wireless module is activated.
Caution
If battery alert light is on on number plate or beep sounds ring, battery has to
be replaced. All batteries must be replaced with new one at once.
Burglar Alert
If door to be opened by abnormal operation such
as door gap break through, burglar alert rings
with more than 80db noisy sound.
How to deactivate burglar or temperature alert
Remove batteries or [password + *] , [Smart key touch]
* if temperature is too high, no deactivation.
Summary of how to use
Self-Diagnosis Table by each LED number flicking
To see the status of product by means of checking flicking number
1. All settings back to the default after factory reset including master
information
Caution
1. Press [Registration] button.
2. Enter “123578951” when number plate lights on
BEEP
Open the battery cover and
press [Registration] button for 5 secs
3. Press [#] button for 2 secs.
Factory default mode is completed with beep sound.
ACTION SELF-DIAGNOSIS
Flicking ALL LEDs - Anti-mischief alert and 1 minute pause
Flicking LED number 2 - Error on password
Flicking LED number 3 - Full of registered password
Flicking LED number 4 - Deadbolt Jam
Flicking LED number 5 - Burglar Alert
Flicking LED number 6 - Unregistered password
Flicking LED number 7 - Already registered address
Flicking LED number 8 - Fire Alarm
Flicking LED number 9 - Dual lock from Indoor unit
Flicking LED number 0
High Temperture Alarm
Once extremely high temperature is detected (60℃± 10℃), locker is automatically
released to open the door with huge sound to secure user
’
s safety.
9V emergency battery
(sold separately)
Sound Pause Mode
Sound is back to the original volume if pause mode is operated once
Reference
Temporary silence function (1 time) regardless latest volume setting
How to
1. Touch number plate and press [#]
2. Press [*] after password or, contact smart key to open the door.
CDL-200P_CAN
Press [Password] and [ * ] to open the door while contacting
terminals of 9V battery to emergency power outlet.
Emergency Power
When door can not be opened due to fully discharged battery.
1. Contact the terminals of 9V battery to emergency power outlet
Factory Reset Mode
Deadbolt Jam alert
When deadbolt is jammed during door open/close, alert sound of
bee bee bee bee” rings 3 times.
Function D efaul t
Password registration/change 1234 [Registration] ⇒ [1] ⇒ Password to register ⇒ [*] ⇒ [*]
Smart key registration None [Registration] ⇒ [2] ⇒ Smart key touch to smart key input unit ⇒
[Registration]
Delete all card [Registration] ⇒ [7] button ⇒ [#] button More than 5 seconds
Open the door indoors Turn down the doorlock handle
Close the door indoors Press the [Doublel Lock]
Password: Touch the Number Plate ⇒ Password ⇒ [*]
Smart key: Smart key touch to smart key input unit
Close the door outdoors After closing the door, Touch the Number Plate
Set registration
authenitication mode Off Password ⇒ [#] [#] ⇒ [8]
Internal dual lock LED setting Password ⇒ [#] [#] ⇒ [5]
Double lock setting Off Hold the [Double lock] of indoor doorlock for 3 seconds
1. Turn down the indoor doorlock handle
2. Press the [Double lock] of indoor doorlock
3. Password ⇒ [#] ⇒ [9]
Etiquette mode function [#] ⇒ Enter password ⇒ [*]
Volume up: Password ⇒ [#] ⇒ [3]
Volume down: Password ⇒ [#] ⇒ [6]
Indoor: Remove the battery
Outdoor: Password ⇒ [*]
* Without registered master password
Registration: [Registration] ⇒ [1] ⇒ [Double lock] ⇒ [#] 5times
⇒ [New master password] ⇒ [*]
* When there is a registered master password
Registration: [Registration] ⇒ [1] ⇒ [Double lock] ⇒ [#] 5times
⇒ [Master password] ⇒ [*] ⇒ [New master password] ⇒ [*]
Delete: [Registration] ⇒ [1] ⇒ [Double lock] ⇒ [#] 5times ⇒
[Master password/9635741] ⇒ [#] ⇒ [1] ⇒ [#]
* Without registered master password
Can't register
* When there is a registered master password
Registration: [Registration] ⇒ [1] ⇒ [Double lock] ⇒ [#] 5times
⇒ [Master password] ⇒ [*] ⇒ [New master card] ⇒ [*]
Delete: [Registration] ⇒ [1] ⇒ [Double lock] ⇒ [#] 5times ⇒
[Master password/9635741] ⇒ [#] ⇒ [2] ⇒ [#]
Delete all master passwords and
cards
Delete: [Registration] ⇒ [1] ⇒ [Double lock] ⇒ [#] 5times ⇒
[Master password/9635741] ⇒ [#] ⇒ [3] ⇒ [#]
Open the door outdoors
Register and delete master
password
Release internal Double lock
Buzzer volume setting
Release alram sound
Register and delete master card
Touch the number
plate and enter your
password
Door Open Alert during automatic lock setting
To inform door open status during automatics lock
setting, alert sound rings 2 times with each 15 seconds
interval if door opened.
1. Press [registration] button
for 5 seconds
2. Press [1]button twce
then press [*]
Beep
Open the battery cover and
press [registration]button
1. Press [registration] button
for 5 seconds
2. Press [0]button twce
then press [*]
Beep
Open the battery cover and
press [registration]button
How to register/delete ZIGBEE
Register
Delete
1. Press [registration] button
for 5 seconds
2. Press [9]button twce
then press [*]
Beep
Open the battery cover and
press [registration]button
1. Press [registration] button
for 5 seconds
2. Press [0]button twce
then press [*]
Beep
Open the battery cover and
press [registration]button
How to register/delete BLE
Register
Delete
Regulatory Compliance
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonableprotection
against harmful interference in a residential installation. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or televisionreception, which can be
determined by turning the equipment off and on, the user is encouragedto try to correct the
interference by one or more of the following
measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet ona circuit different from that to which
the receiver is connected.
•Consultthe dealer or an experiencedradio/ TV technicianfor help.
to the following two conditions:
This product complies with standardsestablishedby the followingregulatory bodies:
• Federal Communications Commission (FCC)
• Industry Canada
IMPORTANT ! Changes or modifications not expressly approved by the manufacturer
could void the user’s authority to operate the equipment.
FCC Radiation Exposure Statement
The equipment complies with FCC Radiation exposure limits set forth for uncontrolled
environment. This equipment should be installed and operated with minimum distance 20 cm
Industry Canada
This device complies with Industry Canadalicenceexempt RSS standard(s). Operation is subject
( 1 ) this device may not cause interference, and ( 2 ) this device must accept any interference,
includinginterference that may cause undesired operation of the device.
This device complies with ISED radiation exposure limits set forth for an uncontrolled environment
and meets the ISED radio frequency(RF) Exposure Guidelines. It is desirablethat it should be
installed and operated keeping the radiator at least 20 cm or more away from person’s body.
Canada, avis d’Industrie Canada (IC)
Cet appareilest conforme aux normes RSS exemptes de licenced’Industrie Canada.
Son utilisation est soumise aux deux conditions.
suivantes : (1) cet appareiln’engendre pas d’interférences,et (2) cet appareildoit tolérer tout type
d’interférences,notamment les interférences pouvant provoquerune utilisation non désirée
del’appareil.
Cet équipement est conforme aux limites établies par Industrie Canadaen matière d’exposition
aux radiations dans un environnement non contrôlé. Cet équipement doit être installé et utilisé
avec une distance minimale de 20 cm entre le radiateur et votre corps.between the radiator and
your body.
FCC
This device complies with Part 15 of the FCC Rules.Operationis subject to the followingtwo
conditions:
1) this device may not cause harmful interference, and
2) this device must acceptany interference received,includinginterference that may cause
undesired operation.

Other Commax Door Lock manuals

Commax CDL-210P User manual

Commax

Commax CDL-210P User manual

Commax CDL-1AR User manual

Commax

Commax CDL-1AR User manual

Commax CDL-30LRC User manual

Commax

Commax CDL-30LRC User manual

Commax CDL-88P User manual

Commax

Commax CDL-88P User manual

Commax CDL-100WL User manual

Commax

Commax CDL-100WL User manual

Commax CDL-800WL User manual

Commax

Commax CDL-800WL User manual

Commax CDL-200L User manual

Commax

Commax CDL-200L User manual

Popular Door Lock manuals by other brands

Johnson Controls IQ Lock-PGK Installation and user guide

Johnson Controls

Johnson Controls IQ Lock-PGK Installation and user guide

Best 7KC Series Service manual

Best

Best 7KC Series Service manual

Austral Lock S14R ILLUSTRATED FITTING INSTRUCTIONS

Austral Lock

Austral Lock S14R ILLUSTRATED FITTING INSTRUCTIONS

ABH 6100 Series installation instructions

ABH

ABH 6100 Series installation instructions

Schlage BE365 installation instructions

Schlage

Schlage BE365 installation instructions

PORT SHIELD user manual

PORT

PORT SHIELD user manual

DESi Utopic 2 user manual

DESi

DESi Utopic 2 user manual

INSYS TwinLock compact manual

INSYS

INSYS TwinLock compact manual

CODELOCKS GLASS DOOR LOCK installation instructions

CODELOCKS

CODELOCKS GLASS DOOR LOCK installation instructions

Windsor 7059 Fitting instructions

Windsor

Windsor 7059 Fitting instructions

SEVENOC M7 manual

SEVENOC

SEVENOC M7 manual

Yale YDG413A user manual

Yale

Yale YDG413A user manual

Samsung shs-h705 quick start guide

Samsung

Samsung shs-h705 quick start guide

Auslock N20 user manual

Auslock

Auslock N20 user manual

SUGATSUNE LAMP HC-30H installation manual

SUGATSUNE

SUGATSUNE LAMP HC-30H installation manual

Lockly FLEX TOUCH installation guide

Lockly

Lockly FLEX TOUCH installation guide

SDC PRO Series installation instructions

SDC

SDC PRO Series installation instructions

I.H.T IDL707 quick start guide

I.H.T

I.H.T IDL707 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.