manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Comnet
  6. •
  7. Transmitter
  8. •
  9. Comnet FVT1C1BM1-M User manual

Comnet FVT1C1BM1-M User manual

This manual suits for next models

1

Other Comnet Transmitter manuals

Comnet FVTR User manual

Comnet

Comnet FVTR User manual

Comnet netwave NWKED User manual

Comnet

Comnet netwave NWKED User manual

Comnet FVT80D8SFP User manual

Comnet

Comnet FVT80D8SFP User manual

Comnet FVT20 User manual

Comnet

Comnet FVT20 User manual

Comnet FVTR1D1A2C1M1 User manual

Comnet

Comnet FVTR1D1A2C1M1 User manual

Comnet FVT801 User manual

Comnet

Comnet FVT801 User manual

Comnet FVT40SFP Series User manual

Comnet

Comnet FVT40SFP Series User manual

Comnet FVT4014SHR User manual

Comnet

Comnet FVT4014SHR User manual

Comnet FVR1031S1 User manual

Comnet

Comnet FVR1031S1 User manual

Comnet FVT8014 User manual

Comnet

Comnet FVT8014 User manual

Comnet FVT11MAC User manual

Comnet

Comnet FVT11MAC User manual

Comnet FVT4014 User manual

Comnet

Comnet FVT4014 User manual

Comnet FVT1031 User manual

Comnet

Comnet FVT1031 User manual

Comnet FVR1031 series Owner's manual

Comnet

Comnet FVR1031 series Owner's manual

Comnet FVT10C1(M,S)1/M Series User manual

Comnet

Comnet FVT10C1(M,S)1/M Series User manual

Comnet FVR1021 Series User manual

Comnet

Comnet FVR1021 Series User manual

Comnet FVT10 User manual

Comnet

Comnet FVT10 User manual

Comnet FDC8ISOT1 User manual

Comnet

Comnet FDC8ISOT1 User manual

Comnet FVT80D4SFP User manual

Comnet

Comnet FVT80D4SFP User manual

Popular Transmitter manuals by other brands

Seneca K120RTD installation manual

Seneca

Seneca K120RTD installation manual

Nautel GV40 installation manual

Nautel

Nautel GV40 installation manual

HumanTechnik cm-light operating instructions

HumanTechnik

HumanTechnik cm-light operating instructions

INOR APAQ C130 TC User instructions

INOR

INOR APAQ C130 TC User instructions

Linear DXS-64 operating instructions

Linear

Linear DXS-64 operating instructions

FeinTech ABT00102 instruction manual

FeinTech

FeinTech ABT00102 instruction manual

Geo Web Pack quick start guide

Geo

Geo Web Pack quick start guide

Inovonics EchoStream EN1210W installation instructions

Inovonics

Inovonics EchoStream EN1210W installation instructions

IKONNIK KA-6 quick start guide

IKONNIK

IKONNIK KA-6 quick start guide

Rohde & Schwarz SR8000 Series System manual

Rohde & Schwarz

Rohde & Schwarz SR8000 Series System manual

Audio Technica UniPak ATW-T93 Installation and operation

Audio Technica

Audio Technica UniPak ATW-T93 Installation and operation

NIVELCO EasyTREK SCA-300 Series Programming manual

NIVELCO

NIVELCO EasyTREK SCA-300 Series Programming manual

Honeywell 5816WMBR installation instructions

Honeywell

Honeywell 5816WMBR installation instructions

Kamstrup READy MTU Installation and operation guide

Kamstrup

Kamstrup READy MTU Installation and operation guide

Omega ZW Series user guide

Omega

Omega ZW Series user guide

ABB Field 264H Instructions for installation

ABB

ABB Field 264H Instructions for installation

Dejero EnGo 3x manual

Dejero

Dejero EnGo 3x manual

Rosemount 4600 Reference manual

Rosemount

Rosemount 4600 Reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INS_FVT1C1B_REV–
12/06/10
PAGE 1
INSTALLATION AND OPERATION MANUAL
FVT1C1B(M,S)1-M
8-BIT DIGITALLY ENCODED VIDEO MINI TRANSMITTER
WITH CONTACT CLOSURE
The FVT1C1B-M video mini-transmitter supports transmission of a fixed video and
a contact closure signal using an 8-bit digitally encoded signal on one multimode
or single mode fiber optic cable. These units are completely transparent to and
universally compatible with any NTSC, PAL, or SECAM CCTV camera systems.
The FVT1C1B-M video transmitter is compatible with the FVR4C4B receivers.
Installation requires no electrical or optical adjustments.
The transmitter incorporates a bi-color (Red/Green) indicating LED for monitoring
proper system operation.
The unit operates on 5VDC power.
The FVT1C1B mini unit operates as a standalone module only.
See Figures 1 – 3 for complete installation details.
INS_FVT1C1B_REV–
12/06/10
PAGE 2
MULTIMODE OR
SINGLE MODE
OPTICAL FIBER
5VDC INPUT
+5V Center
GND Shield
FIGURE 1 – FVT1C1B(M,S)1-M
FIGURE 2 – FVT1C1B(M,S)1-M FIGURE 3 – LED INDICATOR
FIGURE 4 – CONTACT SETTINGS
INSTALLATION AND OPERATION MANUAL FVT1C1B(M,S)1-M
REAR PANELFRONT PANEL
TECH SUPPORT: 1.888.678.9427
VIDEO PRESENT
GREEN A Video signal is
present.
RED No Video signal is
present.
OFF Unit not powered up.
Open Circuit 3.3V
Current Sink to Close ≤1mA
CONTACT
GROUND
INS_FVT1C1B_REV–
12/06/10
PAGE 3
© 2011 Communications Networks Corporation. All Rights Reserved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Networks, LLC.
3 CORPORATE DRIVE | DANBURY, CT 06810 | USA
T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE
T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET
MECHANICAL INSTALLATION INSTRUCTIONS
FIGURE A
Dimensions are for a standard ComNet™ “mini” module
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone module. Units should
be installed in dry locations protected from extremes of temperature
and humidity.
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated
5 VDC @ 1A.
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may
be greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is
not compromised.