FVTR
10-BIT DIGITAL BI-DIRECTIONAL VIDEO OR VIDEO SYNC
The FVTR(M)(S)1 series video transmitter/ receiver supports the transmission of
short-haul quality 10-bit digital bi-directional video or sync over one multimode
or single mode optical fiber.
This module is universally compatible with major CCTV camera manufacturers.
Plug-and-play design ensures ease of installation and no electrical or optical
adjustments are ever required. Bi-color (Red/Green) LED indicators are provided
for rapidly ascertaining equipment operating status.
These units are interchangeable between stand-alone or card mount
configurations. See Figure A on Page 4 for installation instructions.
See Figures 1 – 3 for complete installation details.
INS_FVTR_REV–
02/01/10
PAGE 2
NOTE: Remove Electrical Connector
for Rack Mount Units
FIGURE 2 – FVTRD TRANSCEIVER
FIGURE 1 – FVTR TRANSCEIVER
INSTALLATION AND OPERATION MANUAL FVTR
REAR PANELFRONT PANEL
TECH SUPPORT: 1.888.678.9427
Video termination Switch
Set switch to TERM (Terminate)
when video is not looping to other
video devices or is the last device
in a looping configuration.
MULTIMODE OR SINGLE MODE
OPTICAL FIBER
BLACK
BLACK WITH WHITE STRIPE
INS_FVTR_REV–
02/01/10
PAGE 3
TECH SUPPORT: 1.888.678.9427
INSTALLATION AND OPERATION MANUAL FVTR
FIGURE 3 – LED INDICATORS
LINK VIDEO IN VIDEO OUT POWER
GREEN Communication
link has been
established over
optical fiber
An active video
signal is present on
the BNC connector.
An active video
signal is present on
the BNC connector.
Unit powered up
RED Communication
link has not been
established.
No video input
signal
No video output
signal
–
OFF Unit powered down
INS_FVTR_REV–
02/01/10
PAGE 4
© 2010 Communications Networks Corporation. All Rights Reserved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Networks, LLC.
3 CORPORATE DRIVE | DANBURY, CT 06810 | USA
T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE
T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units
should be installed in dry locations protected from extremes of
temperature and humidity.
STANDALONE MODULE:
The unit is provided with a mounting plate with holes for two No. 6
pan head screws (3 mm or 3.55 mm). Attach the module to a solid
piece of wood using two No. 6 pan head wood screws with a
minimum penetration into the wood of 3/4 inch. (Screws not
supplied). See Figure A.
RACK MODULE:
The unit is designed to be installed in the ComNet 19-inch (483-mm)
EIA standard card-cage rack, the C1-US, C1-EU, or the C1-CH. Follow
these guidelines to install rack cards after performing module setup
procedures.
C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, ComNet recommends that
the power supply be turned off and that the rack power supply
is disconnected from any power source. Note: Remove electrical
connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into
the card guides in the rack until the edge connector at the back
of the card seats in the corresponding slot in the rack’s connector
panel. Seating may require thumb pressure on the top and bottom
of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of
the card is seated against the front of the rack.
MECHANICAL INSTALLATION INSTRUCTIONS
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated 9-12 VDC @ 1A.
WARNING: This unit should be installed in a restricted access location; available through the use of a lock and key or other means of security. Access should
be limited to service personnel who have been instructed about the reasons for the restrictions to the location. Any and all precautions should be taken and
controlled by the authority responsible for the location.
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient
temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not
compromised.
FIGURE A
Dimensions are for a standard ComNet™ one slot module
.156 [3.96 mm]
.313 [7.95 mm]

Other Comnet Transmitter manuals

Comnet FDC8ISOT1 User manual

Comnet

Comnet FDC8ISOT1 User manual

Comnet FVT10 User manual

Comnet

Comnet FVT10 User manual

Comnet FVT1C1BM1-M User manual

Comnet

Comnet FVT1C1BM1-M User manual

Comnet FVT80D4SFP User manual

Comnet

Comnet FVT80D4SFP User manual

Comnet FVT801 User manual

Comnet

Comnet FVT801 User manual

Comnet FVR1031 series Owner's manual

Comnet

Comnet FVR1031 series Owner's manual

Comnet netwave NWKED User manual

Comnet

Comnet netwave NWKED User manual

Comnet FVT1031 User manual

Comnet

Comnet FVT1031 User manual

Comnet FVT4014SHR User manual

Comnet

Comnet FVT4014SHR User manual

Comnet FVT8014 User manual

Comnet

Comnet FVT8014 User manual

Comnet FVT11MAC User manual

Comnet

Comnet FVT11MAC User manual

Comnet FVR1021 Series User manual

Comnet

Comnet FVR1021 Series User manual

Comnet FVT4014 User manual

Comnet

Comnet FVT4014 User manual

Comnet FVTR1D1A2C1M1 User manual

Comnet

Comnet FVTR1D1A2C1M1 User manual

Comnet FVT10C1(M,S)1/M Series User manual

Comnet

Comnet FVT10C1(M,S)1/M Series User manual

Comnet FVT80D8SFP User manual

Comnet

Comnet FVT80D8SFP User manual

Comnet FVR1031S1 User manual

Comnet

Comnet FVR1031S1 User manual

Comnet FVT20 User manual

Comnet

Comnet FVT20 User manual

Comnet FVT40SFP Series User manual

Comnet

Comnet FVT40SFP Series User manual

Popular Transmitter manuals by other brands

Massoth 8131901 manual

Massoth

Massoth 8131901 manual

dji OT-213 user guide

dji

dji OT-213 user guide

Siel EXC-GT Series User and maintenance manual

Siel

Siel EXC-GT Series User and maintenance manual

Quasonix TIMTER Installation and operation manual

Quasonix

Quasonix TIMTER Installation and operation manual

Teslink WPT171AT Installation information for customers & installers

Teslink

Teslink WPT171AT Installation information for customers & installers

Emerson Rosemount 6888A quick start guide

Emerson

Emerson Rosemount 6888A quick start guide

Kramer TP-583Txr user manual

Kramer

Kramer TP-583Txr user manual

Panduit Atlona Omega AT-OME-EX-TX installation guide

Panduit

Panduit Atlona Omega AT-OME-EX-TX installation guide

Harris HTlFM Technical manual

Harris

Harris HTlFM Technical manual

Infineon CYW920829M2EVK-02 quick start guide

Infineon

Infineon CYW920829M2EVK-02 quick start guide

Community Controls 318DOPW2KC MONARCH manual

Community Controls

Community Controls 318DOPW2KC MONARCH manual

Quantec QT412RXA instructions

Quantec

Quantec QT412RXA instructions

Advantech SSPB-3000C Installation and operation manual

Advantech

Advantech SSPB-3000C Installation and operation manual

Directed Avital 474L Replacement

Directed

Directed Avital 474L Replacement

Mhouse TX3 manual

Mhouse

Mhouse TX3 manual

Kahn Easidew I.S. user manual

Kahn

Kahn Easidew I.S. user manual

Nagano Keiki KH41 manual

Nagano Keiki

Nagano Keiki KH41 manual

Vega VEGABAR 81 operating instructions

Vega

Vega VEGABAR 81 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.