1. Safety instructions 5
2. Description of the ER 75i, ER 75i DUO and ER 75i SL routers 6
2.1. Introduction 6
2.2. Delivery Identification 6
2.3. Antenna Connection 8
2.4. SIM Card Reader 8
2.5. Power Supply 8
2.6. Technical parameters 9
2.7. Description of individual components of the router 10
2.7.1. GSM/GPRS/EDGE module 10
2.7.2. Control microcomputer 10
2.8. User interfaces (Connectors) 11
2.8.1. Connection of the PWR Supply Connector 13
2.8.2. Connection of the ETH Connector 14
2.8.3. Connection of the Connector USB 14
2.8.4. Connection of the optional connector PORT1 15
2.8.4.1. Expansion port RS232 15
2.8.4.2. Expansion port RS485 16
2.8.4.3. Expansion port RS422 17
2.8.4.4. Expansion port MBUS 19
2.8.4.5. Expansion port CNT 20
2.9. Technical specification of optional PORT1 21
2.10. Modem status indication 24
2.11. Putting into operation 24
2.12. Mechanical external dimensions and mounting recommendations 25
3. Expansion port mounting 28
3.1. Expansion port mounting for ER 75i and ER 75i DUO router 28
3.2. Expansion port mounting for ER 75i SL router 30
4. Configuration setting over web browser 32
4.1. Network Status 32
4.2. DHCP Status 34
4.3. IPsec status 34
4.4. GPRS Status 34
4.5. DynDNS status 35
4.6. System Log 35
4.7. LAN Configuration 36
4.8. VRRP Configuration 38
4.9. GPRS Configuration 39
4.10. Firewall Configuration 42
4.11. NAT Configuration 43
4.12. OpenVPN Tunnel Configuration 45
4.13. IPsec Tunnel Configuration 48
4.14. GRE Tunnel Configuration 50
4.15. L2TP tunnel Configuration 51
4.16. DynDNS Client Configuration 53
4.17. NTP Client Configuration 54
4.18. SNMP Configuration 55
4.19. SMS Configuration 56

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
CONTENTS
3
4.20. Expansion port Configuration 61
4.21. Start-up script 62
4.22. Automatic update configuration 62
4.23. Change password 63
4.24. Set real time clock 63
4.25. Set SMS service center address 64
4.26. Unlock SIM Card 64
4.27. Send SMS 64
4.28. Backup Configuration 64
4.29. Restore Configuration 65
4.30. Update firmware 65
4.31. Reboot 65
4.32. Default settings 66
4.32.1. LAN Configuration 66
4.32.2. VRRP Configuration 66
4.32.3. Firewall Configuration 66
4.32.4. GPRS Configuration 67
4.32.5. NAT Configuration 67
4.32.6. OpenVPN Tunnel Configuration 68
4.32.7. IPsec Tunnel Configuration 69
4.32.8. GRE Tunnel Configuration 70
4.32.9. L2TP Configuration 70
4.32.10. DynDNS Configuration 70
4.32.11. NTP Configuration 70
4.32.12. SNMP Configuration 71
4.32.13. SMS Configuration 71
4.32.14. External Port Configuration 72
4.32.15. Startup Script 72
4.32.16. Automatic Update 72
5. Configuration setting over Telnet 73
6. Driver installation 74
7. Control by AT commands 76
8. Possible problems 76
9. Reference 76
10. FAQ 76
11. Customer’s care 77
12. Product disposal information 78
13. Guarantee Claim Guidelines 79
14. Guarantee certificate 82

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
CONTENTS
4
Symbols used
Danger – important notice, which may have an influence on the user’s safety
or the function of the device.
Attention – notice of possible problems, which can arise in specific cases.
Information, notice – information, which contains useful advice or special interest.
GPL license
Source codes under GPL license are available free of charge by sending email to
Conel s.r.o., Sokolska 71, 562 04 Usti nad Orlici, Czech Republic
Issue in CZ, 7/8/2009

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
SAFETY INSTRUCTIONS
5
1. Safety instructions
Please, observe the following instructions:
•The communication module must be used in compliance with any and all applicable
international and national laws and in compliance with any special restrictions regulating
the utilization of the communication module in prescribed applications and environments.
•To prevent possible injury to health and damage to appliances and to ensure that all the
relevant provisions have been complied with, use only the original accessories.
Unauthorised modifications or utilization of accessories that have not been approved may
result in damage to the communication module and in a breach of applicable regulations.
Unauthorized modifications or utilization of accessories that have not been approved may
result in the termination of the validity of the guarantee.
•The communication module must not be opened. Only the replacement of the SIM card is
permitted.
•Caution! The SIM card could be swallowed by small children.
•Voltage at the feed connector of the communication module must not be exceeded.
•Do not expose the communication module to extreme ambient conditions. Protect the
communication module against dust, moisture and high temperature.
•It is recommended that the communication module should not be used at petrol stations.
We remind the users of the duty to observe the restrictions concerning the utilization
of radio devices at petrol stations, in chemical plants, or in the course of blasting works
in which explosives are used.
•Switch off the communication module when travelling by plane. Utilization of the
communication module in a plane may endanger the operation of the plane or interfere with
the mobile telephone network, and may be unlawful. Failure to observe these instructions
may result in the suspension or cancellation of telephone services for the respective client,
or, it may result in legal sanctions; it may also result in both eventualities.
•When using the communication module in close proximity of personal medical devices,
such as cardiac pacemakers or hearing aids, you must proceed with heightened caution.
•If it is in the proximity of TV sets, radio receivers and personal computers, the telephone
may cause interference.

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
DESCRIPTION
6
2. Description of the ER 75i, ER 75i DUO and ER 75i SL
routers
2.1. Introduction
EDGE router is a compact electronic device based on the module which enables data
transfers using GSM, GPRS and EDGE technologies.
Primarily, the router expands the capabilities of the module by the option of connecting
more PCs by means of the built-in Ethernet interface. In addition, the firmware of the router
provides automatic establishment and maintenance of GPRS connection. By means
of integration of a DHCP server it provides the users with simple installation and Internet
access.
In addition, the router is equipped with a USB 2.0 Full Speed interface which is designed
only for connection to a PC with Windows 2000, Windows XP or Windows Vista operating
system. For operation it is sufficient to install drivers from the supplied CD to the PC.
By consumer request it is possible to equip the router with a modulus port PORT1
and extend the functionality of EDGE router about RS232, RS485/RS422, M-BUS or CNT (I/O
module).
The EDGE router has three versions. The first version is the basic ER 75i, the second
version is the ER 75i DUO with two SIM cards and last version is the ER 75i SL in an
aluminum box.
Examples of Possible Applications
•mobile office
•image transmission
•security system
•telematics
•telemetry
•remote monitoring
•monitoring of traffic information
•vending and dispatcher machines
2.2. Delivery Identification
Specimen Label:
Trade name Type name Other
ER 75i ER-75i Version with 1 SIM
ER 75i DUO ER-75i-DUO Version with 2 SIM
ER 75i SL ER-75i-SL Version in aluminum box

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
DESCRIPTION
7
Specimen label of optional PORT1:
Trade name of PORT1 Type name of PORT1 Power supply
Expansion port RS232 XC-232 Internal power supply
Expansion port RS485-RS422 XC-485-422 Internal/external power supply
Expansion port MBUS XC-MBUS External power supply
Expansion port CNT XC-CNT Internal power supply
Basic delivered set of router includes:
•EDGE router ER 75i or ER 75i DUO or ER 75i SL,
•power supply,
•crossover UTP cable,
•external magnetic antenna,
•installation CD containing instructions and drives,
•plastic clips for the DIN bar with fixing screws.
In addition to the basic it is possible to deliver:
•expansion port RS232, RS485/RS422, M-BUS or CNT (separation columns are in
distribution),
•USB A-B cable.

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
DESCRIPTION
8
Router ER 75i is standardly designed for:
•mounting to a panel using through holes (only version ER 75i and ER 75i DUO),
•or possibility to be put on a worktop,
•mounting onto the DIN rail by the plastic clips, which are included.
2.3. Antenna Connection
The whip antenna is connected to the router using an FME on the back panel.
External whip antenna:
2.4. SIM Card Reader
The SIM card reader for 3 V and 1.8 V SIM cards is located on the front panel
of the modem. For putting the modem into operation it is necessary to insert an activated SIM
card with unblocked PIN in the reader.
1. Make sure that the modem is not being powered.
2. Press the small yellow button next to the reader to eject the reader holder.
3. Insert the SIM card in the reader holder and slide it in the reader.
2.5. Power Supply
The router requires +10 V DC to +30 V DC supply. Protection against reversal
of polarity without signaling is built into the modem.
The power consumption during receiving is 1W. The peak power consumption during
data sending is 5,5 W. For correct operation it is necessary that the power source is able to
supply a peak current of 500 mA.

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
DESCRIPTION
9
2.6. Technical parameters
GSM module MC75i
Complies with standards EN 301 511, V9.0.2
EN ETSI 301 489-1 V1.9.1
EN 60950-1:06 ed.2
Frequency bands EGSM850, EGSM900, GSM1800
and GSM1900
Transmit power Class 4 (2W) for EGSM850
Class 4 (2W) for EGSM900
Class 1 (1W) for GSM1800
Class 1 (1W) for GSM1900
Temperature range Operation
Storage -20 oC to +55 oC
-40 oC to +85 oC
Supply voltage 10 až 30 V DC
Consumption Reception
Transmission 1 W
5,5 W
Dimensions ER 75i, ER 75i DUO
ER 75i SL
30x90x102 mm (attachment to DIN rail
35mm)
42x86x94 mm (attachment to DIN rail
35mm)
Weight 140 g
Antenna connector FME – 50 Ohm
User interface ETH
USB
PORT1
Ethernet – connector RJ45 (10/100 Mbit/s)
USB 2.0 – connector USB-B
Optional – connector RJ45 (150 b/s -
- 230400 b/s), RS232, RS485/RS422,
M-BUS, CNT

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
DESCRIPTION
10
2.7. Description of individual components of the router
2.7.1. GSM/GPRS/EDGE module
The MC75i OEM module is used for GSM network wireless communication. It is
integrated into the printed circuit board. The slide-out SIM card reader is accessible from
the front panel. The FME antenna connector is accessible from the back panel.
The router is equipped with a USB 2.0 Full Speed interface which is brought to the
USB-B connector marked USB. The MC75i module is connected to the control computer via
the RS-232 high-speed serial interface.
GSM/GPRS/EDGE module
•Communicates in four GSM bands (850MHz, 900MHz, 1800MHz, and 1900MHz).
•In the GPRS mode it is able to transmit in three „Time Slot“ and receive in two (GPRS
multi-slot class 10 – the maximum bit rate of reception is 42.8 kb/s) or transmit in one
„Time Slot“ and receive in four (GPRS multi-slot class 12 – the maximum bit rate
of reception is 85.6 kb/s).
•In the EDGE mode it is able to transmit in three „Time Slot“ and receive in two (EDGE
multi-slot class 10 – the maximum bit rate of reception is 118.4 kb/s) or transmit in one
„Time Slot“ and receive in four (GPRS multi-slot class 12 – the maximum bit rate
of reception is 236.8 kb/s).
•Supports coding schemes CS1 to CS4 and MCS1 to MCS9.
Beware! The transmitting and receiving in timeslots depends on the operator networks
possibilities.
2.7.2. Control microcomputer
The core of the router is a 32-bit microprocessor with 16 MB RAM, 4 MB FLASH
EEPROM, serial interface RS232 and an Ethernet interface 10/100 Mbit/s. The microcomputer
is connected to the MC75i OEM module through the serial interface and controls
the communication via GSM/GPRS. Towards to the user it is connected on the Ethernet
interface.
The software is built on the uClinux operating system.
The router supports services such as DHCP, NAT, GRE, IPSec tunnels, etc.
The router settings are saved in the FLASH EEPROM memory. All configuration
of the modem can be done through a web interface (HTTP) which is security password
controlled.

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
DESCRIPTION
11
2.8. User interfaces (Connectors)
On the back panel of the router the following connectors are located:
•one RJ12 connector or MRT9 (PWR) – for connection of the power supply adapter,
•one RJ45 connector (ETH) – for connection into the local computer network,
•one RJ45 connector (optional PORT1) – for connection of the local any arrangement over
RS232, RS485/422, M-BUS or CNT,
•one FME connector (ANT) – for connection of the antenna,
•one USB-B connector (USB) – for connection of the router to the PC.
Rear panel ER 75i and ER 75i DUO
Front panel ER 75i
Front panel ER 75i DUO

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
DESCRIPTION
12
Rear panel ER 75i SL
Front panel ER 75i SL

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
DESCRIPTION
13
2.8.1. Connection of the PWR Supply Connector
•Panel socket RJ12.
Pin
number Signal
mark Description
1 +UN Positive pole of DC supply voltage (+10 to +30 VDC)
2 NC Signal not connected
3 NC Signal not connected
4 +UN Positive pole of DC supply voltage (+10 to +30 VDC)
5 GND Negative pole of DC supply voltage
6 GND Negative pole of DC supply voltage
Circuit example:
•Panel socket MRT9.
Pin
number Signal
mark Description
1 +UN Positive pole of DC supply voltage (+10 to +30 VDC)
2 GND Negative pole of DC supply voltage
Circuit example:
The positive pole +UN is marked by a red socket on the power supply.
Pin 1 – +UN
Pin 2 – NC
Pin 3 – NC
Pin 4 – +UN
Pin 5 – GND
Pin 6
–
GND
Router
DC
+
Pin 1 – +UN
Pin 2 – GND Router
DC +

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
DESCRIPTION
14
2.8.2. Connection of the ETH Connector
Panel socket RJ45.
Pin
number Signal
mark Description Data flow
direction
1 TXD+ Transmit Data – positive pole Input/Output
2 TXD- Transmit Data – negative pole Input/Output
3 RXD+ Receive Data – positive pole Input/Output
4 EPWR+ DC supply voltage from the switch – positive pole
5 EPWR+ DC supply voltage from the switch – positive pole
6 RXD- Receive Data – negative pole Input/Output
7 EPWR- DC supply voltage from the switch – negative pole
8 EPWR- DC supply voltage from the switch – negative pole
ATTENTION! Port ETH is not POE (Power Over Ethernet) compatible!
The ETH router connection:
2.8.3. Connection of the Connector USB
Panel socket USB-B.
Pin
number Signal
mark Description Data flow
direction
1 VCC Positive pole of 5V DC supply voltage
2 USB data - USB data signal – negative pole Input/Output
3 USB data + USB data signal – positive pole Input/Output
4 GND Negative pole of DC supply voltage
The USB router connection:
Router
USB
ETH
PORT1
PWR
UTP cable
Switch
Router
USB
ETH
PORT1
PWR
USB cable A-B

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
DESCRIPTION
15
2.8.4. Connection of the optional connector PORT1
Panel socket RJ45.
2.8.4.1. Expansion port RS232
(RS232 – DCE – Data Communication Equipment)
Pin
No. Signal
name Description Data flow
direction
1 RTS Request To Send Input
2 CTS Clear To Send Output
3 DTR Data Terminal Ready Input
4 DSR Data Set Ready – connected to +3,3 V over 330 Ohm
resistor Output
5 GND GROUND – signal ground
6 RXD Receive Data Output
7 CD Carrier Detect Output
8 TXD Transmit Data Input
Circuit example:
The router connection to the PC:
•cable KD2 is connected to serial port PC (example COM1)
Router
ETH
PORT1
PWR
Cable KD-2
Pin 1 – RTS
Pin 2 – CTS
Pin 3 – DTR
Pin 4 – DSR
Pin 5 – GND
Pin 6 – RXD
Pin 7 – CD
Pin 8 – TXD
Router
Meter GND
RXD
TXD

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
DESCRIPTION
16
The router connection to equipment with full-value RS232 interface:
2.8.4.2. Expansion port RS485
Pin
No. Signal
name Description Data flow
direction
1 SGND Signal and power supply ground
2 SGND Signal and power supply ground
3 TxRx- RS485 B (-) Input/Output
4 TxRx+ RS485 A (+) Input/Output
5 TxRx- RS485 B (-) Input/Output
6 TxRx+ RS485 A (+) Input/Output
7 +12V EXT External power supply
8 +12V EXT External power supply
ATTENTION! Power supply is selected on the expansion port RS485 by help
of a jumper, 2.9. If galvanic separation is required the converter must have an external
power supply.
Circuit example of the equipment with a router with data length less then 10 m:
Router
ETH
PORT1
PWR
Cable KD-2

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
DESCRIPTION
17
Circuit example of the equipment with a router with data length more than 10 m:
At RS485 data cable more then 10m it is need to use overvoltage protection
on the router side!
2.8.4.3. Expansion port RS422
Pin
No. Signal
name Description Data flow
direction
1 SGND Signal and power supply ground
2 SGND Signal and power supply ground
3 RxD- Receive Data (-) Output
4 RxD+ Receive Data (+) Output
5 TxD- Transmit Data (-) Input
6 TxD+ Transmit Data (+) Input
7 +12V EXT External power supply
8 +12V EXT External power supply
ATTENTION! Power supply is selected on the expansion port RS422 by help
of a jumper, 2.9. If galvanic separation is required the converter must have an external
power supply.
Circuit example of the equipment with router with data length less then 10 m:

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
DESCRIPTION
18
Circuit example of the equipment with a router with data length more than 10 m:
At RS422 data cable more then 10m it is need to use overvoltage protection
on the router side!

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
DESCRIPTION
19
2.8.4.4. Expansion port MBUS
Pin
No. Signal
name Description Data flow
direction
1 SGND Signal and power supply ground
2 SGND Signal and power supply ground
3 TxRx- MBUS B (-) Input/Output
4 TxRx+ MBUS A (+) Input/Output
5 TxRx- MBUS B (-) Input/Output
6 TxRx+ MBUS A (+) Input/Output
7 +12V EXT External power supply
8 +12V EXT External power supply
ATTENTION! External supply is for converter MBUS!
If galvanic separation is required the converter must have external power supply.
Circuit example of the equipment with a router with data length less than 10 m:
Circuit example of the equipment with a router with data length more than 10 m:
If an M-BUS data cable more then 10m it is need to use overvoltage protection
on the router side!

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de
DESCRIPTION
20
2.8.4.5. Expansion port CNT
Pin
number Signal mark Description Data flow direction
1 BIN1/CNT1 Binary input/counter input Input
2 BIN2/CNT2 Binary input/counter input Input
3 BIN3 Binary input Input
4 BIN4 Binary input Input
5 GND Signal ground
6 OUT1 Binary output (open collector) Output
7 AN1 Analogue input Input
8 AN2 Analogue input Input
The user interface CNT is for monitoring and processing of analogue and binary
signals and to control (settings) of binary signals. Available are 2 counter and 2 binary inputs
or 4 binary inputs, 2 analogue inputs and 1 binary output. The settings of binaries
and counter inputs by the help of firmware in which the single inputs and output is defined.
Typical connection of a router measuring circuits:
This manual suits for next models
1
Table of contents
Other Conel Network Router manuals

Conel
Conel ER75i v2 SL User manual

Conel
Conel xr5i sl User manual

Conel
Conel UR5i v2 SL User manual

Conel
Conel EDGE ER75i User manual

Conel
Conel LR77 v2 SL User manual

Conel
Conel LR77 v2 SL User manual

Conel
Conel EDGE ER75i User manual

Conel
Conel XR5i v2 User manual

Conel
Conel ER75i v2 SL User manual

Conel
Conel Bivias v2 User manual

Conel
Conel ER75i v2 SL Guide

Conel
Conel UCR11 User manual

Conel
Conel UCR11 v2 SL User manual

Conel
Conel SPECTRE v3 LTE User manual

Conel
Conel UR5i v2 SL Instruction sheet

Conel
Conel CR10 v2 SL User manual

Conel
Conel UR5i a User manual

Conel
Conel RR75i v2 User manual

Conel
Conel UR5 v2 User manual

Conel
Conel UR5 User manual