manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cres Cor
  6. •
  7. Commercial Food Equipment
  8. •
  9. Cres Cor H-339225 Series Manual

Cres Cor H-339225 Series Manual

This manual suits for next models

3

Other Cres Cor Commercial Food Equipment manuals

Cres Cor H138NPS1813CLA Manual

Cres Cor

Cres Cor H138NPS1813CLA Manual

Cres Cor AQUATEMP Series User manual

Cres Cor

Cres Cor AQUATEMP Series User manual

Cres Cor CSH12210 Series Manual

Cres Cor

Cres Cor CSH12210 Series Manual

Cres Cor H-339-135-BK Series User manual

Cres Cor

Cres Cor H-339-135-BK Series User manual

Cres Cor HH Series Manual

Cres Cor

Cres Cor HH Series Manual

Cres Cor H138NPS36CLCMQRL i7 Manual

Cres Cor

Cres Cor H138NPS36CLCMQRL i7 Manual

Cres Cor H135SUA6A Manual

Cres Cor

Cres Cor H135SUA6A Manual

Cres Cor H138NPSCMQ Series Manual

Cres Cor

Cres Cor H138NPSCMQ Series Manual

Cres Cor H138NPSCLCMCQRL Manual

Cres Cor

Cres Cor H138NPSCLCMCQRL Manual

Cres Cor H-339-X-C Series Manual

Cres Cor

Cres Cor H-339-X-C Series Manual

Cres Cor Fire-N-IceCube Manual

Cres Cor

Cres Cor Fire-N-IceCube Manual

Cres Cor 120PH Series Manual

Cres Cor

Cres Cor 120PH Series Manual

Cres Cor 130B Series Manual

Cres Cor

Cres Cor 130B Series Manual

Cres Cor H138NPSCLCMC5QRL Manual

Cres Cor

Cres Cor H138NPSCLCMC5QRL Manual

Cres Cor H137WSUA C Series Manual

Cres Cor

Cres Cor H137WSUA C Series Manual

Cres Cor H138NPSCDOM CE Series Manual

Cres Cor

Cres Cor H138NPSCDOM CE Series Manual

Cres Cor H-339-1813C-GMR Manual

Cres Cor

Cres Cor H-339-1813C-GMR Manual

Cres Cor H137WSUA12 Manual

Cres Cor

Cres Cor H137WSUA12 Manual

Cres Cor RO151033 User manual

Cres Cor

Cres Cor RO151033 User manual

Popular Commercial Food Equipment manuals by other brands

Costco 5P-08WT manual

Costco

Costco 5P-08WT manual

Beper BT.651Y manual

Beper

Beper BT.651Y manual

Blue Seal EF30 Installation & operation manual

Blue Seal

Blue Seal EF30 Installation & operation manual

Tecfrigo Snelle 400 GS installation instructions

Tecfrigo

Tecfrigo Snelle 400 GS installation instructions

Follett PFT Series Operation and maintenance manual

Follett

Follett PFT Series Operation and maintenance manual

MEFE CAT 206 PTR User manual and maintenance

MEFE

MEFE CAT 206 PTR User manual and maintenance

Diamond AL1TB/H2-R2 Installation, Operating and Maintenance Instruction

Diamond

Diamond AL1TB/H2-R2 Installation, Operating and Maintenance Instruction

Salva IVERPAN FC-18 User instructions

Salva

Salva IVERPAN FC-18 User instructions

Allure Melanger JR6t Operator's manual

Allure

Allure Melanger JR6t Operator's manual

saro FKT 935 operating instructions

saro

saro FKT 935 operating instructions

Hussmann Rear Roll-in Dairy Installation & operation manual

Hussmann

Hussmann Rear Roll-in Dairy Installation & operation manual

Cornelius IDC PRO 255 Service manual

Cornelius

Cornelius IDC PRO 255 Service manual

Moduline HSH E Series Service manual

Moduline

Moduline HSH E Series Service manual

MINERVA OMEGA DERBY 270 operating instructions

MINERVA OMEGA

MINERVA OMEGA DERBY 270 operating instructions

Diamond OPTIMA 700 Installation, use and maintenance instructions

Diamond

Diamond OPTIMA 700 Installation, use and maintenance instructions

Diamond G9/PLCA4 operating instructions

Diamond

Diamond G9/PLCA4 operating instructions

Cuppone BERNINI BRN 280 Installation

Cuppone

Cuppone BERNINI BRN 280 Installation

Arneg Atlanta Direction for Installation and Use

Arneg

Arneg Atlanta Direction for Installation and Use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

OPERATING and MAINTENANCE INSTRUCTIONS
For INSULATED HAND-LIFT CABINETS
MODEL H-339225 and H339SS1814CBE
5925 Heisley Road • Mentor, OH 44060-1833
Insulated
Hand-lift Cabinets FL-0520-BE
Rev. 8 (5/13) Page 1 of 4
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
HOW TO INSTALL UNIT: (Figure 1)
See FL-2211-BE (enclosed) for “Stacking
Instructions”.
1. Plug cord into receptacle in back of the unit.
2. Turn plug clockwise to lock.
3. Plug other end into 15-amp wall outlet.
4. Place cabinet in a well ventilated area.
5. If no casters are provided, the base must be sealed
to the counter or oor with grout or caulk to
maintain sanitation certication.
6. Push the switch on, turn the thermostat to No. 10
and run the unit for one hour.
NOTE: DO NOT PUT IN FOOD! This step is to
burn off manufacturing oils and excessive
adhesive.
6. Let the cabinet cool and wipe inside clean with
detergent and hot water before use.
HOW TO OPERATE UNIT: (Figure 2)
1. Push switch “ON”. Yellow light will come on.
2. Preheat cabinet for 45 minutes; the cabinet
temperature is factory preset.
4. Put food into cabinet.
To Turn Off Unit:
Push switch “OFF”. The yellow light will go off.
NOTE: The digital thermometer will ash if cabinet
temperature is below 140°F/60°C or above
250°F/60°C.
Call the factory if you need different settings.
ELECTRICAL SPECIFICATIONS:
MODELS: Volts Watts Amps Hertz Phase NEMA
H-339225-01 / HOT CABINET TOP 120 900 7.5 60 1 5-15
H-339225-02 / PROOFER BOTTOM 120 900 7.5 60 1 5-15
H-339SS1814CBE / HOT CABINET ONLY 120 900 7.5 60 1 5-15
FIG. 1
THERMOSTAT
COVER THERMOMETER
SWITCH
FIG. 2
OPERATING and MAINTENANCE INSTRUCTIONS
For INSULATED HAND-LIFT CABINETS
MODEL H-339225 and H339SS1814CBE
5925 Heisley Road • Mentor, OH 44060-1833
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Insulated
Hand-lift Cabinets FL-0520-BE
Rev. 8 (5/13) Page 2 of 4
BEFORE CLEANING CABINET:
1. Remove Power Cord from cabinet.
2. Do NOT hose cabinet with water.
3. Do NOT get water on controls.
4. Do NOT use abrasives or harsh
chemicals.
Hints:
1. Wipe up spills as soon as possible.
2. Clean cabinet regularly to avoid heavy dirt build-up.
3. Make a test spot with cleaner.
4. Follow manufacturer’s directions on cleaner.
5. Do not mix cleaners
6. Avoid drips and splashes.
HOW TO CLEAN UNIT:
SOIL CLEANER METHOD
CABINET
DIRT
Mild detergent* and hot water,
or mild abrasive cleaner.
1. Use soft, damp cloth.
2. Rinse with hot water.
3. Wipe dry.
Steam (no strong alkaline
additive)
1. Rinse after steam cleaning.
2. Wipe dry.
FINGERPRINTS,
GREASE OIL
Detergent* and hot water.
1. Wipe with soft, damp cloth.
2. Rinse with hot water.
3. Wipe dry.
Chemical oven cleaner.** Follow oven cleaner manufacturer’s
directions.
Mild abrasive cleaner.
Oily or waxy cleaner. Apply with soft, clean cloth.
WATER SPOTS Mild abrasive cleaner. Wipe with damp cloth.
* Mild detergents include soaps and non-abrasive cleaners
**Be sure your cleaner is good for stainless steel for use on cabinet body;
and for aluminum, for use on the rack insert (pan slides)
HOW TO ADJUST THE DOOR LATCH:
1. For vertical adjustment
(Up and down movement):
a. Loosen (2) screws located in magnetic
strike on cabinet.
b. Move strike up or down for alignment
to magnet on latch.
c. Tighten screws to secure
2. For horizontal adjustment
(Greater or lesser magnetic draw):
a. Loosen four (4) screws in latch on door.
b. Move latch forward or backward to
adjust magnetic draw.
c. Tighten screws to secure.
WARNING
OPERATING and MAINTENANCE INSTRUCTIONS
For INSULATED HAND-LIFT CABINETS
MODEL H-339225 and H339SS1814CBE
5925 Heisley Road • Mentor, OH 44060-1833
Insulated
Hand-lift Cabinets FL-0520-BE
Rev. 8 (5/13) Page 3 of 4
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
HOW TO REVERSE DOOR HARDWARE
FOR OPPOSITE HAND (Refer to Fig. 3 [hinge]):
1. Pop off hinge covers with screwdriver.
2. Remove screws from hinges to cabinet; remove door
and unscrew latch strike from cabinet.
3. Remove hinges, latch and all remaining screws from
the right and left side of door. Keep all screws.
4. Re-mount hinges and latch in the same hole pattern on
the opposite sides of the door. Plug all extra holes with
screws.
5. Remove all screws from the front sides of cabinet (not
the top and bottom).
6. Hold door up to cabinet and screw hinges to the
cabinet.
7. Open door and re-mount the latch strike to cabinet.
8. Plug all extra holes with screws and snap on the hinge
covers.
REPLACEMENT PARTS
120V 240V
Cabinet Receptacle 0713-011 0713-012
Cord Set 0810-149-01-K 0810-150-01
Switch 0808-113-K 0808-113-01-K
Heater Kit 0811-066-K 0811-066-1K
Thermostat Kit 0848-008-ACK 0848-008-ACK
Terminal Block 0852-091 0852-091
Thermometer 5238-034-K 5238-034-K
Door Latch Kit 1006-122-01 K
Strike Kit 1006-122-02 K
Hinge Kit 0519-074-K
Gasket Kit 0861-077
Casters 0569-306-K
Casters w/Brake 0569-306-BK
Transformer 0769-159-01
Door Kit 5508-093-SSK
Thermostat Cover H339225-15-K
Rack Insert (1) H339225-03
TROUBLE-SHOOTING CHART
FAILURE POSSIBLE CAUSE/CHECK
1. Unit does not heat: 1a. Thermostat turned up.
1b. Switch is “ON”.
1c. Cord is plugged into cabinet.
1d. Cord is plugged into outlet.
1e. Circuit breaker/fuse for
wall outlet
2. Unit will not turn off: 2a. Thermostat turned down.
2b. Switch is “OFF”
If cause is none of the above, refer to our list of
authorized service agencies, FL-1400.
FIGURE 3
DOOR
TOP
C’SK SCREWS
#10-24 X 1"
COVER
HINGE
CABINET
BODY
#10-24 X 3/4"
C'SK SCREWS
HOW TO ADJUST CABINET TEMPERATURE:
1. Unscrew the thermostat cover on the control panel.
2. The following knob settings are guidelines for
temperatures.
No. 4 averages about 140°F/60°C.
No. 4-1/4 averages about 145°F/62°C
No. 6-3/4 averages about 170°F/77°C
No. 7 averages about 180°F/82°C.
OPERATING and MAINTENANCE INSTRUCTIONS
For INSULATED HAND-LIFT CABINETS
MODEL H-339225 and H339SS1814CBE
5925 Heisley Road • Mentor, OH 44060-1833
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Insulated
Hand-lift Cabinets FL-0520-BE
Rev. 8 (5/13) Page 4 of 4
WIRING DIAGRAM
LEGEND
H1 HEATER - BOTTOM
H2 & 3 HEATER - RIGHT & LEFT SIDE
5-15P PLUG (Power Cord), 120V. 15A.
6-15P PLUG (Power Cord), 240V. 15A.
SSENSOR - AIR
SW SWITCH - POWER (Lighted)
TB TERMINAL BLOCK
TCB TEMPERATURE CONTROL
BOARD
TH THERMOMETER, DIGITAL
SLEEVING (12 PLACES)