manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Crosswater
  6. •
  7. Control Unit
  8. •
  9. Crosswater TH2-RGH User manual

Crosswater TH2-RGH User manual

Other Crosswater Control Unit manuals

Crosswater WLBP3001R Plus User manual

Crosswater

Crosswater WLBP3001R Plus User manual

Crosswater US-BL1000EV User manual

Crosswater

Crosswater US-BL1000EV User manual

Crosswater PBS-RGH User manual

Crosswater

Crosswater PBS-RGH User manual

Crosswater EV1253EC User manual

Crosswater

Crosswater EV1253EC User manual

Crosswater KL0007WC User manual

Crosswater

Crosswater KL0007WC User manual

Crosswater SE350DC User manual

Crosswater

Crosswater SE350DC User manual

Crosswater US-DL2001RC User manual

Crosswater

Crosswater US-DL2001RC User manual

Crosswater US-WF1000EV User manual

Crosswater

Crosswater US-WF1000EV User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Applicable Standards/Codes
TH2-RGH
15122953
For ease of installation you will need:
●To read the installation instructions completely before beginning.
●To read all warnings, care, and maintenance information.
15122953 4
Installation Dimensions
IAPMO certified to meet or exceed the following:
• ASME A112.18.1/CSA B125.1
• Uniform Plumbing Code
• National Plumbing Code of Canada
• ASSE 1016
3 1/8"
5 7/8"4 13/16"
4 3/16"
3 9/16"
2"
5 1/4"
6 5/16"-6 1/2"
2 3/4"
3/4"-14NPT 3/4"-14NPT
3/4"-14NPT 3/4"-14NPT
4 1/4"
5 1/8"
2 1/8"-2 5/8"
2 3/4"-3 5/16"
Dual-control Thermostatic Valve Rough
TH2-RGH
Installation Instructions
Before beginning installation, check for any
damage that may have occurred during transport.
Note: Damage claims cannot be made during
or after installation.
TH2-RGH
Installation Instructions
151229533
15122953 2
Replacement Parts
2
This valve is designed to fit into a
wall that is 2-3/4” to 3 -1/4" from
finished wall to the back of the valve.
If necessary,extensions can be
purchased separately.
1
Turn off the water supplies. Install the
valve so the finished wall will fit
between the markers on the mud
guard.
2
Using mounting holes secure the
valve making sure the "UP" label
outlet is on top. Facing the valve,
the hot supply must be on the left
and the cold on the right.
3
5
Warning:If soldering is required
for any connection,remove the
cartridge and check valve
assemblies before soldering.
6
Connect top outlet with proper
fittings.Note: it is suggested that you
anchor all water lines.
Installation completed.
8
2-3/4" - 3-1/4" 2-3/4" - 3-1/4"
Best if finished wall
is flush to this surface.
4
Connect valve body 3/4-NPT inlets
to water supplies using the proper
fittings. Warning: This valve does
not offer a back-to-back installation
option.
Warning
7
1.Pressure test and flush the valve.
a. Prior to testing, remove cartridge and check valve assemblies.
b. Plug the outlet and check for leaks.
c. After testing, flush system.
d. Remove shower outlet plug. Re-install the cartridge and check valve assemblies.
2.Check for leaks.
Mounting hole
2
a b c d
2
1
3
4
5
6
7
Ordered Separately if needed
NO. Description Part NO.
1
2
3
Extension kit 9K3172
Cartridge 5K217404PL
Nut 5K217405NT
Check valve 5K013107PL
4
6
5
Temperature control rings
Complete Mud Guard
5K202716PL
5K202720PL
7
Cartridge 5K202711NT
This thermostatic valve has been preset at the factory
to deliver water at a maximum of 120ºF. If you would
like to change this setting please refer to the
temperature change instructions noted in the trim
installation instructions for this valve.
TH2-RGH
Installation Instructions
151229533
15122953 2
Replacement Parts
2
This valve is designed to fit into a
wall that is 2 3/4” to 3 5/16” from
finished wall to the back of the valve.
If necessary extensions can be
purchased separatley.
1
Turn off the water supplies. Install the
valve so the finished wall will fit
between the markers on the mud
guard.
2
Using mounting holes secure the
valve making sure the "UP" label
outlet is on top. Facing the valve,
the hot supply must be on the left
and the cold on the right.
3
5
Warning:If soldering is required for
any connection remove the cartridge
and check valve assemblies before
soldering.
6
Connect top outlet with proper
fittings.Note: it is suggested that you
anchor all water lines.
Installation completed.
8
2 3/4"-3 5/16"
2 3/4"-3 5/16"
Best if finished wall
is flush to this surface.
4
Connect valve body 3/4-NPT inlets
to water supplies using the proper
fittings. Warning: This valve does
not offer a back-to-back installation
option.
Warning
7
1.Pressure test and flush the valve.
a. Prior to testing, remove cartridge and check valve assemblies.
b. Plug the outlet and check for leaks.
c. After testing, flush system.
d. Remove shower outlet plug. Re-install the cartridge and check valve assemblies.
2.Check for leaks.
Mounting hole
2
a b c d
2
1
3
4
5
6
7
Order separately if needed
NO. Description Part NO.
1
2
3
Extension kit 9K3172
Cartridge 5K217404PL
Nut 5K217405NT
Check valve 5K013107PL
4
6
5
Temperature control rings
Complete Mud Guard
5K202716PL
5K202720PL
7
Cartridge 5K202711NT
This thermostatic valve has been preset at the factory
to deliver water at a maximum of 120ºF. If you would
like to change this setting please refer to the
temperature change instructions noted in the trim
installation instructions for this valve.
Applicable Standards/Codes
VALVE ONLY
Two Outlet, Volume Control, Dual Handle Therm Valve
TH2-RGHTH2-RGH
15122953
Installation Instructions
For easy installation of your faucet you will need:
●To read all the installation completely before beginning.
●To read all warnings, care, and maintenance information.
15122953 4
Installation Dimensions
IAPMO certified to meet or exceed the following:
• ASME A112.18.1/CSA B125.1
• Uniform Plumbing Code
• National Plumbing Code of Canada
• ASSE 1016
3-1/8"
5-7/8"4-3/4"
4-1/4"
2"
5-1/4"
6-1/4" - 6-1/2"
2-3/4"
3/4"-14NPT 3/4"-14NPT
3/4"-14NPT 3/4"-14NPT
3-1/2"
4-1/4"
5-1/8"
2-1/8" - 2-5/8"
2-3/4" - 3-1/4"
Warranty - This Crosswater London product is covered by a limited lifetime warranty. For full details, terms and conditions please visit our website.
For further information contact:Crosswater London, 393 Fortune Blvd., Milford, MA 01757
Toll free number: 844-XWATER-1 (844-992-8371) tel: 508-381-0433 fax: 508-381-6068
www.crosswaterlondon.com
email: technical@crosswaterlondon.com
Issue date: 15092019