Installation Instructions
Tubing
cutter
Adjustable
wrench
Pipe wrench
Channel
locks Hexagonal
key Teon
tape
Cross head
screwdriver
Flat head
screwdriver
Plumbers’ putty
or caulking
15/8”
51/2”
Finished
wall
77/8”
95/8”
COLD
INLET
HOT
INLET
81/4”
61/2”
Belgravia Exposed Thermostatic Valve
US-BL1000EV
Introduction
Installation notes
This exposed valve is suitable for use with all water systems up to a
maximum operating pressure of 72 psi and static pressure of 144 psi,
beyond which pressure-reducing valves must be installed . The
minimum water pressure requirement is 14.5 psi.
The outlet is controlled by a ow control cartridge, commonly used for
a main shower head.
IMPORTANT:
Please read these instructions carefully before beginning and
retain for future reference.
Roughing-in dimensions
Tools required
The installation must comply with all plumbing codes including local
codes. This valve is a mixing device and therefore requires the water
supplies to be reasonably balanced, otherwise we recommend a
pressure-reducing valve to be installed.
The valve is fitted with integral single-check valve cartridges,
therefore the exposed valve is protected against cross-flow due to
unbalanced line pressures.
Installing shut-off valves on incoming supply lines is recommended
for ease of maintenance.
IMPORTANT: Turn off the main water supply before connecting
to any existing pipework.
WARNING! Please check for any hidden pipes and cables, electric
or otherwise,before drilling holes in a wall or floor.