manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Crown
  6. •
  7. Computer Hardware
  8. •
  9. Crown IQ-PIP-USP2 User manual

Crown IQ-PIP-USP2 User manual

IQ-PIP-
USP2/CN
ULTRA SERIES
When installed in Crown’s Com-Tech
10 Series and Macro-Tech 02 Series
amplifiers, the IQ-PIP-USP2/CN cre-
ates the industry’s first CobraNet™ compatible
amplifier. The module integrates the latest
CobraNet™ audio-networking technology and
a full complement of audio signal processing
in a package that requires ZERO rack space!
In addition, the IQ-PIP-USP2/CN connects the
amplifier to the IQ Bus of an IQ System, allow-
ing the amplifier to be controlled and monitored
via IQ.
The IQ-PIP-USP2/CN offers an extensive list
of features, including output signal delay for
precise acoustic alignment, auto standby for
reduced energy costs, plus eight independent,
fully adjustable filters per channel.
The IQ-PIP-USP2/CN also provides on-screen
error reporting of fault, high temperature,
and excessive distortion, so you can know
quickly if any changes occur in your amplifier’s
status. Meanwhile, the IQ-PIP-USP2/CN’s real-
time load supervision feature ensures you will
be notified immediately of any changes to the
load.
Offering crisp, clear sound and the wide
dynamic range possible with full 24-bit con-
verters, the IQ-PIP-USP2/CN provides unprec-
edented power and flexibility in one compact—
and very affordable—module.
For more details about the Crown
IQ-PIP-USP2/CN, contact the Crown Technical
Support Group at 800-342-6939 or
219-294-8200. Also, visit the Crown Audio
website at www.crownaudio.com.
* You must have a PIP2-compatible amplifier to use the
IQ-PIP-USP2/CN. To determine if your amplifier is PIP2-
compatible, look for the PIP2 logo on the back of the
amplifier. The IQ-PIP-USP2/CN is NOT compatible with
older Crown PIP amplifiers.
Specifications
General
Internal Controls: An 8-segment DIP switch
sets the IQ address (decimal range: 1–250).* A
Reset/Preset switch, accessible with a straight-
ened paper clip through the PIP panel, selects
the next user preset if pressed for less than 2
seconds, resets the PIP to preset “0”if pressed
for more than 2 seconds.
* If address “0”is selected, the IQ-PIP-USP2/CN will operate
in stand-alone mode. In this mode, the IQ Bus port is deacti-
vated.
Connectors: IQ Bus: RJ-45 connector for input/
output, RJ-45 connector for daisy output.
AUX In/Aux Out: RJ-11 connector. CobraNet™
Audio Input and Output: RJ-45 connector for
Primary Network, RJ-45 connector for Second-
ary Network.
Indicators: A yellow DATA indicator flashes
when a valid IQ command is received from the
IQ System via the IQ Bus. A green PRESET indi-
cator flashes to indicate the user preset number
currently selected in memory (if the PRESET
indicator does not flash the preset number
when selected, this indicates the preset has
been modified by the user). Two dual-color
indicators provide status of the CobraNet™net-
work. The left indicator on the Primary and
Secondary RJ-45 connectors flashes green if
the network link is connected and operating
normally, and flashes red if the port is in a
“Fault”condition. The right indicator on the Pri-
mary and Secondary RJ-45 connectors is ON
green if the port is “in-use,”and is ON orange
if the port is operating as the CobraNet™“Con-
ductor.”
Memory Backup: 1 Mbyte non-volatile FLASH
memory for backup of run-time parameters,
presets, and program storage. Capable of
greater than 10 year data retention and esti-
mated 20+ year life-cycle.
Power Requirements: Power draw: 410 mA
@ +24 VDC and 40 mA @ –24 VDC. When
installed into a Crown PIP2-compatible ampli-
fier, the unit receives ±24 VDC from the ampli-
fier. No external power is required.
Total Power Dissipation: 10.5 watts.
IQ Bus Data Communication
Protection: If communication is lost, the unit
will continue to function with the last com-
mands received.
Data Rate: 38.4 K BAUD.
Data Format: Serial, binary, asynchronous; 1
start bit; 1 stop bit; 8 data bits; no parity.
IQ Bus Interface Type: Optically isolated 20
milliamp serial loop.
Operation: Half duplex.
Transmission Distance: Variable from 200 to
3000 feet (61 to 914 m), depending upon wire
capacitance. Typically 1000 feet (305 M) using
shielded twisted-pair wire, #26 AWG or larger.
Can be extended with an IQ Repeater.
Audio
Please note: The audio specifications are referenced to 0.775
V (0 dBu). Measurements were made at the output of the
IQ-PIP-USP2/CN module, itself.
Digital Signal Processor (DSP): 60 MHz
Motorola 56002 DSP processor provides 30
million operations per second.
Analog to Digital Conversion (ADC): 24-bit, 48
kHz sample rate, Delta-Sigma converter.
Digital to Analog Conversion (DAC): 24-bit, 48
kHz sample rate, Delta-Sigma converter.
Signal to Noise Ratio: Greater than 100 dB
(A-weighted, 20 Hz to 20 kHz, audio sourced
from muted CobraNet™channels).
Frequency Response: ±0.5 dB, 20 Hz to 20 kHz
(referenced to 1 kHz, 0 dBu input signal).
Distortion: Less than 0.05% THD+N, 20 Hz
to 20 kHz (referenced to 1 kHz, 0 dBu input
signal).
Crosstalk: better than –80 dB, full-scale input
level, 20 Hz to 20 kHz input frequency sweep,
20 Hz to 20 kHz bandwidth.
Listen Bus Distortion: 0.1% THD+N, 20 Hz to
20 kHz bandwidth (1 kHz, 0 dB full scale input
signal at the active PIP2 AO1 or AO2 input).
Listen Bus Signal to Noise: Greater than 80 dB,
20 Hz to 20 kHz bandwidth (audio sourced from
muter amplifier channels. Measured at receiv-
ing CobraNet™node outputs).
Maximum Output Level: +20 dBu.
IQ System Data Acquisition
Input/Output Monitor Accuracy: Typically ±1 dB.
Features
•Receives any two of 64 channels on a
repeater-based CobraNet™network, or any
two of up to 3000 channels on a switch-based
CobraNet™network.
•Transmit channels are user-selectable from
16 bit to 24 bit.
•Sends “Listen-Bus”amplifier output monitor
signals via CobraNet™.
•Implements dual-redundant network ports
for the ultimate in robust audio networking.
•24 bit analog to digital conversion, and 24
bit, 48 kHz DSP processing.
•Free IQ for Windows software provides easy
setup and monitoring of all IQ-PIP-USP2/CN
parameters.
•Up to seven different filter types are available
for a total of 16 filters on-board.
•Signal delay and compressor/limiter for each
channel.
•User-selectable presets for easy recall of
settings.
•Load supervision for real-time warning of
load problems.
•Reliable FLASH memory backs up all param-
eters.
•The best three-year “No-Fault”full warranty
in the business!
Crown International
P.O. Box 1000
Elkhart, IN 46515-1000
TEL: 219-294-8200
FAX: 219-294-8FAX
www.crownaudio.com
08/01
Crown’s Three-Year, No-Fault, Fully Transferrable Warranty
Crown offers a Three-Year, No-Fault, Full Warranty for every new Crown IQ component—an
unsurpassed industry standard. With this unprecedented No-Fault protection, your new Crown
IQ component is warranted to meet or exceed original specifications for the first three years
of ownership. During this time, if your IQ component fails, or does not perform to original
specifications, it will be repaired or replaced at our expense. About the only things not covered
by this warranty are those losses normally covered by insurance and those cuased by intentional
abuse. And the coverage is transferable, should you sell your IQ component.
See your authorized Crown dealer for full warranty disclosure and details. For customers outside
of the USA, please contact your authorized Crown distributor for warranty information or call
219-294-8200..
Specifications subject to change without prior notice. Latest
information available at www.crownaudio.com.
Crown, Com-Tech, IQ, IQ System and Macro-Tech are
registered trademarks of Crown International. Other trade-
marks are the property of their respective owners.
Printed in U.S.A.
© 2001 Crown Audio, Inc.
IQ-PIP-USP2/CN SIgnal Flow Block Diagram
132292-2
IQ-PIP-
USP2/CN

Other manuals for IQ-PIP-USP2

5

This manual suits for next models

1

Other Crown Computer Hardware manuals

Crown IQ-PIP-LITE User manual

Crown

Crown IQ-PIP-LITE User manual

Crown IQ-P.I.P.-SLM User manual

Crown

Crown IQ-P.I.P.-SLM User manual

Crown PIP-FXT User manual

Crown

Crown PIP-FXT User manual

Crown IQ-PIP-USP3 User manual

Crown

Crown IQ-PIP-USP3 User manual

Crown IQ-PIP-USP3/CN User manual

Crown

Crown IQ-PIP-USP3/CN User manual

Crown PIP-ATN User manual

Crown

Crown PIP-ATN User manual

Crown IQ-P.I.P User manual

Crown

Crown IQ-P.I.P User manual

Crown PIP-EDC User manual

Crown

Crown PIP-EDC User manual

Crown PIP-ATX User manual

Crown

Crown PIP-ATX User manual

Crown PIP-USL User manual

Crown

Crown PIP-USL User manual

Crown IQ-P.I.P User manual

Crown

Crown IQ-P.I.P User manual

Crown ScreenArray PIP-3632 User manual

Crown

Crown ScreenArray PIP-3632 User manual

Crown PIP-FPX User manual

Crown

Crown PIP-FPX User manual

Crown P.I.P.-102 User manual

Crown

Crown P.I.P.-102 User manual

Crown ScreenArray PIP-3632 User manual

Crown

Crown ScreenArray PIP-3632 User manual

Crown IQ-P.I.P-AP Assembly instructions

Crown

Crown IQ-P.I.P-AP Assembly instructions

Crown IQ-PIP-LITE User manual

Crown

Crown IQ-PIP-LITE User manual

Crown IQ-P.I.P.-MEM User manual

Crown

Crown IQ-P.I.P.-MEM User manual

Crown PIP-BEQ User manual

Crown

Crown PIP-BEQ User manual

Crown PIP-AF User manual

Crown

Crown PIP-AF User manual

Crown PIP-XOV User manual

Crown

Crown PIP-XOV User manual

Crown IQ-P.I.P-SMT User manual

Crown

Crown IQ-P.I.P-SMT User manual

Crown IQ-PIP-USP2 User manual

Crown

Crown IQ-PIP-USP2 User manual

Crown IQ-PIP-USP2 User manual

Crown

Crown IQ-PIP-USP2 User manual

Popular Computer Hardware manuals by other brands

American Megatrends MegaRAC 780 Series Specifications

American Megatrends

American Megatrends MegaRAC 780 Series Specifications

Atmel REB233-XPRO user guide

Atmel

Atmel REB233-XPRO user guide

JENCO 6312 DT Operation manual

JENCO

JENCO 6312 DT Operation manual

Symbol MR 100 user manual

Symbol

Symbol MR 100 user manual

Yamaha PLG100-VH owner's manual

Yamaha

Yamaha PLG100-VH owner's manual

crescendo WS G3 manual

crescendo

crescendo WS G3 manual

Texas Instruments DEM-DAI1802 user guide

Texas Instruments

Texas Instruments DEM-DAI1802 user guide

NEC N8140-817 Setup guide

NEC

NEC N8140-817 Setup guide

Infineon PSoC CY3290-CYAT8168X Guide

Infineon

Infineon PSoC CY3290-CYAT8168X Guide

Mobiletek N10/N20 EVB user manual

Mobiletek

Mobiletek N10/N20 EVB user manual

Advantech RSB-4221 user manual

Advantech

Advantech RSB-4221 user manual

Adaptec SCSI 58300 Installation and user guide

Adaptec

Adaptec SCSI 58300 Installation and user guide

Processor Technology Sol-PCB Documentation

Processor Technology

Processor Technology Sol-PCB Documentation

Lantronix N-FXE 02B Series user guide

Lantronix

Lantronix N-FXE 02B Series user guide

Silver Monkey Stormy 120 mm user manual

Silver Monkey

Silver Monkey Stormy 120 mm user manual

Axiom SBC8163 user manual

Axiom

Axiom SBC8163 user manual

National Instruments USRP-2940 Getting started

National Instruments

National Instruments USRP-2940 Getting started

DeLOCK 61114 user manual

DeLOCK

DeLOCK 61114 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.