manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CTC Union
  6. •
  7. Switch
  8. •
  9. CTC Union IFS-402GSM-4PH24 User manual

CTC Union IFS-402GSM-4PH24 User manual

Installation
The switch comes with both wall mount and DIN rail hardware
brackets. When installing the DIN rail bracket, be sure to correctly
align the orientation pin.
Figure 8. DIN Rail Figure 9. Wall Mount
The switch with DIN Rail bracket has a steel spring in the upper
rail of the bracket. This spring is compressed for mounting and
un-mounting by applying downward force.
Figure 10. Mounting Figure 11.Un-mounting
Introduction
IFS-402GSM-4PH(E)24 models are managed industrial grade Fast
Ethernet PoE (Power over Ethernet) switches that provide stable
and reliable Ethernet transmission. Housed in rugged DIN rail or
wall mountable enclosures, these switches are designed for harsh
environments, such as industrial networking and intelligent
transportation systems (ITS) and are also suitable for many
military and utility market applications where environmental
conditions exceed commercial product specifications. Standard
operating temperature range models (-10°C to 60°C) and wide
operating temperature range models (-40°C to 75°C) fulfill the
special needs of industrial automation applications.
Features
Redundant dual DC inputs 24/48VDC
DCV 'boost' feature; regulated 55VDC PoE output voltage
IP30 rugged metal housing
Wide temperature range -40°C~75°C (IFS-402GSM-4PHE24)
Supports many advanced Ethernet L2 functions
Console, Telnet (SSH), Web and SNMP management
Industrial grade EMS, EMI, UL60950-1, EN50121-4,
EN61000-6-2, EN61000-6-4
Specifications
Ethernet Interface
Standards: IEEE802.3 (10Base-T), 802.3u (100Base-TX)
RJ-45 (shielded) Ports: 4 ports
Speed: 10/100M
Optical
Standards: IEEE802.3u (100Base-FX), 802.3z (1000Base-X),
802.3ab (1000Base-T)
2 ports, SFP based
Speed: 100/1000M (Manual)
Switch Features
Store & Forward Switch
Supports IEEE802.3x Flow Control
Auto MDI/MDI-X
Duplex: Full/Half (Auto-negotiation per IEEE802.3u)
Switching Fabric: 4.8Gbps (Non-blocking)
MAC Table: 8K
MTU: 64~9600 bytes
Quick Installation Guide
IFS-402GSM-4PH24
IFS-402GSM-4PHE24
Industrial Grade Fast Ethernet Managed PoE Switches
Specifications (cont.)
Power over Ethernet
4 PoE enabled ports, Alternate A Mode
Supports IEEE802.3af 15.4watts PoE per port
Supports IEEE802.3at 30watts PoE+ per port (120W budget)
Positive (VCC+) pins 1,2; Negative (VCC-) pins 3,6
Power
Absolute Input Range: 20VDC~57VDC
Reverse Polarity Protection: Yes
Dual Power Inputs: Yes
Connector: Removable terminal block
Consumption:
Items
Input Voltage
Total Power
Consumption
Device Power
Consumption
PoE Budget
Boost
Efficiency
24VDC
134.8W
7.1W
120W
94.0%
48VDC
132W
8.5W
120W
97.2%
Mechanical
Water & Dust Proof: IP30 Protection
Dimensions: 106 mm (D) x 62.5 mm (W) x 134.8 mm (H)
Mounting: DIN-Rail, Wall Mount (Kits included)
Weight: 715 g
Environmental
Operating Temperature: -10°C~60°C (IFS-402GSM-4PH24)
-40°C~75°C (IFS-402GSM-4PHE24)
Storage Temperature: -40°C~85°C
Humidity: 5%~95% (Non-condensing)
Certifications
EMC: CE
EMI (Electromagnetic Interference): FCC, FCC Part 15 Subpart
B Class A, CE EN55022 Class A
Railway Traffic: EN50121-4
Immunity for Heavy Industrial Environment: EN61000-6-2
Emission for Heavy Industrial Environment: EN61000-6-4
EMS (Electromagnetic Susceptibility) Protection Level:
EN61000-4-2 (ESD) Level 3, Criteria B
EN61000-4-3 (RS) Level 3, Criteria A
EN61000-4-4 (Burst) Level 3, Criteria A
EN61000-4-5 (Surge) Level 3, Criteria B
EN61000-4-6 (CS) Level 3, Criteria A
EN61000-4-8 (PFMF, Magnetic Field) Field Strength:
300A/m, Criteria A
Safety: UL60950-1 ●Shock: EN60068-2-27
Freefall: EN60068-2-32 ●Vibration: EN60068-2-6
MTBF: 276,161 hours (MIL-HDBK-217)
[email protected]
V1.1
- 1 -
www.ctcu.com
- 2 -
- 7 -
To download this QIG or a more complete user manual, please visit
http://www.ctcu.com/Industrial/
T+886-2-26591021
F+886-2-26590237
E[email protected]
CTC Union Technologies Co., Ltd.
Far Eastern Vienna Technology Center
(Neihu Technology Park)
8F, No. 60 Zhouzi St., Neihu District, Taipei 114
Taiwan
© 2014 CTC Union Technologies Co., Ltd.
All trademarks are the property of their respective owners.
Technical information in this document is subject to change without notice.
Connectors
LAN and Fiber Connection
IFS-402GSM-4PH(E)24 PoE switches have 4 electrical LAN ports
(labeled 1~4) and 2 fiber ports (SFP based, labeled Fiber 5~6) on the
front panel. The LAN ports that utilize shielded RJ-45 connectors support
10/100M; while the fiber SFP ports support 100/1000M.
PoE Ports
All 4 LAN ports support PoE (Power over Ethernet) per IEEE802.3af
(15.4W) or IEEE802.3at (30W) for connection to standard PoE PD (Power
Devices) such as IP Cameras, Access Points, IP Phones, Digital Signage,
etc. PoE eliminates the need to run separate power to these devices
thereby simplifying deployment and reducing expenses.
The LAN ports may also connect to any non-PoE device for normal
Ethernet transmission without any damage to the non-PoE device or to
this device.
RJ-45 Ethernet Port Pinouts
Figure 2. RJ-45 Ethernet Port Pinouts
RJ-45 Ethernet & PoE Pin Assignments
Pin
No.
RJ-45 Ethernet
100Base-TX
PoE Output
1
RX+
V+
2
RX-
V+
3
TX+
V-
4
-
5
-
6
TX-
V-
7
-
8
-
Power and Alarm
Figure 5. Terminal Block
A removable terminal block on the top panel provides both power
and alarm connections. Power can be provided through the dual inputs
from separate sources. The alarm relay contact can be wired into an
alarm circuit which senses an alarm condition when the contact is
broken. The alarm relay is normally closed when there is no alarm
condition. The alarm conditions are user programmable through
management to include power, link faults or other fault conditions.
Please note that the alarm relay contact can only support 1A current at
24VDC. Do not apply voltage and current that exceed these
specifications.
CLI & Web Basic Operation
IFS-402GSM-4PH(E)24 are managed Fast Ethernet PoE switch devices.
Initial configuration (assignment of IP address) may be accomplished via
the RS-232 console and a PC or laptop running terminal emulation
software. Configure the terminal as follows:
115200 speed, 8 data bits, no parity, 1 stop bit, no flow control
IFS-402GSM-4PH(E)24 PoE switches use a command line interface (CLI)
through the serial port. Once the IP address has been configured, a web
browser can be used to configure the device through a more easy to use
GUI (graphical user interface). Please refer to the operation manual on
the CDROM.
Using the provided console cable, connect the RJ-45 to the
"CONSOLE" port and the DB9 to PC COM port. Apply power to the switch.
At the "Username:" prompt, enter 'admin' (lower case, no quotes). Just
press Enter when prompted for password.
To set the IP address and subnet mask issue this command:
> ip address 1 192.168.0.250/24
(example: sets VID 1 to 192.168.0.250, subnet 255.255.255.0)
NOTE: The factory default IP address is 10.1.1.1 with mask
255.255.255.0
CONSOLE Port
The RJ-45 port labeled “CONSOLE”is an RS-232 terminal port for local
management. These models use a “light”CLI (Command Line Interface)
in addition to a user friendly Web interface and industry standard SNMP.
See page 5 for basic CLI and Web operation.
One RJ-45 to DB-9 cable is provided with this device. CONSOLE port
pinouts (Figure 2) and RS-232 DB-9 (Figure 3) connector are illustrated
below together with RJ-45 to DB-9 signal mapping information. Use the
supplied cable to connect the RJ-45 CONSOLE port to a console PC.
Figure 3. CONSOLE Port Pinout
Figure 4. RS-232 (Female) Pinout
RJ-45 to DB-9 Signal Mapping
DB-9 (Female)
Direction
RJ-45
Signal
Pin
Pin
Signal
RXD
2
3
TXD
TXD
3
6
RXD
GND
5
5
GND
LED Indicators
LED
Color
Definition
PWR1/
PWR2
Green
Power is connected and active at the
PWR1/PWR2 input terminal connection.
Off
PWR1/PWR2 is not connected.
Fault
Amber
When one or more of the programmable
alarm conditions is active.
Off
Normal operation without faults.
Alarm conditions are all disabled.
CPU ACT
Green
Lit during normal use, indicating a healthy
condition of the running CPU.
Ring
Master
Yellow
Lit when this unit is the 'master' in a ring
and all units are configured for u-Ring or
ERPS.
LAN
LINK/ACT
Green
Ethernet link is up.
Blinking
Blinking when there is Ethernet traffic.
Off
No Ethernet link.
10/100
Green
The connected LAN speed is 10/100M.
Off
No Ethernet link.
FIBER
LINK/ACT
Green
The fiber SFP link is up.
Blinking
Blinking when there is data traffic.
Off
No fiber link.
PoE
Green
The respective LAN port has successfully
negotiated PoE and is supplying output
power to the remote connected PD.
Blinking
One of the PoE faults (overload, short
circuit, port failure at startup) occurs.
Off
PD is not connected or output power is not
provided.
Application
- 4 -
- 6 -
Figure 7. u-Ring Topology and Application
Figure 1. IFS-402GSM-4PH(E)24 Front Panel
- 5 -
- 3 -
Fault
Figure 6. Alarm Relay Circuit
Normally Closed (NC)
www.ctcu.com

This manual suits for next models

1

Other CTC Union Switch manuals

CTC Union PHB-200 User manual

CTC Union

CTC Union PHB-200 User manual

CTC Union GSW-3208M User manual

CTC Union

CTC Union GSW-3208M User manual

CTC Union IFS-402GSM User manual

CTC Union

CTC Union IFS-402GSM User manual

CTC Union JB320 Series User manual

CTC Union

CTC Union JB320 Series User manual

CTC Union IFS+402GSM-4PHE24 User manual

CTC Union

CTC Union IFS+402GSM-4PHE24 User manual

CTC Union IGS-401F User manual

CTC Union

CTC Union IGS-401F User manual

CTC Union IGS-804SM-SE-8PHE User manual

CTC Union

CTC Union IGS-804SM-SE-8PHE User manual

CTC Union IGS-1608SM-SE User manual

CTC Union

CTC Union IGS-1608SM-SE User manual

CTC Union GSW-1005MS User manual

CTC Union

CTC Union GSW-1005MS User manual

CTC Union ITP-800-8PH24 User manual

CTC Union

CTC Union ITP-800-8PH24 User manual

CTC Union JB330 Series User manual

CTC Union

CTC Union JB330 Series User manual

CTC Union JB230 Series User manual

CTC Union

CTC Union JB230 Series User manual

CTC Union ITP-500 User manual

CTC Union

CTC Union ITP-500 User manual

CTC Union SB142 User manual

CTC Union

CTC Union SB142 User manual

CTC Union IGS-2408SM-24PH User manual

CTC Union

CTC Union IGS-2408SM-24PH User manual

CTC Union IGS-803SM-8PH24 User manual

CTC Union

CTC Union IGS-803SM-8PH24 User manual

CTC Union IGS+803SM-8PH User manual

CTC Union

CTC Union IGS+803SM-8PH User manual

CTC Union MX262 Series User manual

CTC Union

CTC Union MX262 Series User manual

CTC Union ITP-1204GTM-12PHE User manual

CTC Union

CTC Union ITP-1204GTM-12PHE User manual

CTC Union IFS-803GSM-8PH24 User manual

CTC Union

CTC Union IFS-803GSM-8PH24 User manual

CTC Union SB282 Series User manual

CTC Union

CTC Union SB282 Series User manual

CTC Union SB142 User manual

CTC Union

CTC Union SB142 User manual

CTC Union FS-802GS-8PH User manual

CTC Union

CTC Union FS-802GS-8PH User manual

CTC Union SB152 Series User manual

CTC Union

CTC Union SB152 Series User manual

Popular Switch manuals by other brands

Enerwave WF15S installation instructions

Enerwave

Enerwave WF15S installation instructions

Sitecom AC-1004 user manual

Sitecom

Sitecom AC-1004 user manual

Enterasys Matrix 2G4072-52 Configuration guide

Enterasys

Enterasys Matrix 2G4072-52 Configuration guide

KROHNE OPTISWITCH 5300 C Handbook

KROHNE

KROHNE OPTISWITCH 5300 C Handbook

Harman Kardon ABH 4000 owner's manual

Harman Kardon

Harman Kardon ABH 4000 owner's manual

Dell S60 System manual

Dell

Dell S60 System manual

Cisco 6509 - Catalyst Chassis Switch installation guide

Cisco

Cisco 6509 - Catalyst Chassis Switch installation guide

steute ZS 92 S EXTREME Series Mounting and wiring instructions

steute

steute ZS 92 S EXTREME Series Mounting and wiring instructions

Ross NK-3G144 user guide

Ross

Ross NK-3G144 user guide

SIMEREC PCS-2 quick start guide

SIMEREC

SIMEREC PCS-2 quick start guide

Elko inels RFUS-11 quick start guide

Elko

Elko inels RFUS-11 quick start guide

HP A7990A - StorageWorks SAN Director 4/16 Blade... Hardware reference guide

HP

HP A7990A - StorageWorks SAN Director 4/16 Blade... Hardware reference guide

Samsung SM-V505 user manual

Samsung

Samsung SM-V505 user manual

ZyXEL Communications GS1100 Series brochure

ZyXEL Communications

ZyXEL Communications GS1100 Series brochure

Omron A6T Series quick start guide

Omron

Omron A6T Series quick start guide

Cisco 2900 - Catalyst Expansion Module Mounting instructions

Cisco

Cisco 2900 - Catalyst Expansion Module Mounting instructions

ATEN ALTUSEN KW1000 quick start guide

ATEN

ATEN ALTUSEN KW1000 quick start guide

NETGEAR GSS108E Installation

NETGEAR

NETGEAR GSS108E Installation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.