manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CTC Union
  6. •
  7. Switch
  8. •
  9. CTC Union IGS-803SM User manual

CTC Union IGS-803SM User manual

Installation
The switch comes with both wall mount and DIN rail hardware
brackets. When installing the DIN rail bracket, be sure to correctly
align the orientation pin.
Figure 7. DIN Rail Figure 8. Wall Mount
The switch with DIN Rail bracket has a steel spring in the upper
rail of the bracket. This spring is compressed for mounting and
un-mounting by applying downward force.
Figure 9. Mounting Figure 10.Un-mounting
Introduction
IGS-803SM(-E) are managed industrial grade Gigabit switches
that provide stable and reliable Ethernet transmission. Housed in
rugged DIN rail or wall mountable enclosures, these switches are
designed for harsh environments, such as industrial networking
and intelligent transportation systems (ITS) and are also suitable
for many military and utility market applications where
environmental conditions exceed commercial product
specifications. Standard operating temperature range models
(-10°C to 60°C) and wide operating temperature range models
(-40°C to 75°C) fulfill the special needs of industrial automation
applications.
Features
Redundant dual DC inputs 12/24/48VDC
IP30 rugged metal housing
Wide temperature range -40°C~75°C (IGS-803SM-E)
Supports many advanced Ethernet L2 functions
Console, Telnet (ssh), Web and SNMP management
Industrial grade EMS, EMI, UL60950-1, EN50121-4,
EN61000-6-2, EN61000-6-4
Specifications
Ethernet Interface
Standards: IEEE802.3 (10Base-T), 802.3u (100Base-TX),
802.3ab (1000Base-T)
RJ-45 (shielded) Ports: 8 ports
Speed: 10/100/1000M (Auto)
Optical Interface
Standards: IEEE802.3u (100Base-FX), 802.3z (1000Base-X),
802.3ab (1000Base-T)
3 ports, SFP based
Speed: 100/1000M (Manual)
Switch Features
Store & Forward Switch
Supports IEEE802.3x Flow Control
Auto MDI/MDI-X
Duplex: Full/Half (Auto-negotiation per IEEE802.3u)
Switching Fabric: 22Gbps (Non-blocking)
Packet Buffer: 1Mb
MAC Table: 8K
MTU: 64~9600 bytes
Quick Installation Guide
IGS-803SM
IGS-803SM-E
Industrial Grade Managed Gigabit Ethernet Switches
Specifications (cont.)
Power
Absolute Input Range: 9.6VDC~60VDC
Reverse Polarity Protection: Yes
Dual Power Inputs: Yes
Connector: Removable terminal block
Consumption: 9.6W
Mechanical
Water & Dust Proof: IP30 Protection
Dimensions: 116 mm (D) x 64 mm (W) x 152 mm (H)
Mounting: DIN-Rail, Wall Mount (Kits included)
Weight: 790 g
Environmental
Operating Temperature: -10°C~60°C (IGS-803SM)
-40°C~75°C (IGS-803SM-E)
Storage Temperature: -40°C~85°C
Humidity: 5%~95% (Non-condensing)
Certifications
EMC: CE
EMI (Electromagnetic Interference): FCC, FCC Part 15 Subpart
B Class A, CE EN55022 Class A
Railway Traffic: EN50121-4
Immunity for Heavy Industrial Environment: EN61000-6-2
Emission for Heavy Industrial Environment: EN61000-6-4
EMS (Electromagnetic Susceptibility) Protection Level:
EN61000-4-2 (ESD) Level 3, Criteria B
EN61000-4-3 (RS) Level 3, Criteria A
EN61000-4-4 (Burst) Level 3, Criteria A
EN61000-4-5 (Surge) Level 3, Criteria B
EN61000-4-6 (CS) Level 3, Criteria A
EN61000-4-8 (PFMF, Magnetic Field) Field Strength:
300A/m, Criteria A
Safety: UL60950-1
Shock: EN60068-2-27
Freefall: EN60068-2-32
Vibration: EN60068-2-6
MTBF: 404,589 hours (MIL-HDBK-217)
[email protected]
V1.2
- 1 -
- 2 -
- 7 -
To download this QIG or a more complete user manual, please visit
http://www.ctcu.com/Industrial/
T+886-2-26591021
F+886-2-26590237
E[email protected]
CTC Union Technologies Co., Ltd.
Far Eastern Vienna Technology Center
(Neihu Technology Park)
8F, No. 60 Zhouzi St., Neihu District, Taipei 114
Taiwan
© 2014 CTC Union Technologies Co., Ltd.
All trademarks are the property of their respective owners.
Technical information in this document is subject to change without notice.
www.ctcu.com
Connectors
Figure 1. Front Panel
LAN & Fiber Ports
IGS-803SM(-E) switches have 8 electrical LAN ports (labeled
1~8) and 3 fiber ports (SFP based, labeled 1~3) on the front panel.
The LAN ports that utilize shielded RJ-45 connectors support
10/100/1000M; while the fiber SFP ports support 100/1000M.
CONSOLE Port
The RJ-45 port labeled “CONSOLE”is an RS-232 terminal port
for local management. These models use a “light”CLI (Command
Line Interface) in addition to a user friendly Web interface and
industry standard SNMP. See page 5 for basic CLI and Web
operation.
One RJ-45 to DB-9 cable is provided with this device. CONSOLE
port pinouts (Figure 2) and RS-232 DB-9 (Figure 3) connector are
illustrated below together with RJ-45 to DB-9 signal mapping
information. Use the supplied cable to connect the RJ-45
CONSOLE port to a console PC.
Figure 2. CONSOLE Port Pinout
Figure 3. RS-232 (Female) Pinout
CLI & Web Basic Operation
IGS-803SM(-E) are managed Gigabit Ethernet switch devices.
Initial configuration (assignment of IP address) may be
accomplished via the RS-232 console and a PC or laptop running
terminal emulation software. Configure the terminal as follows:
115200 speed
8 data bits
no parity
1 stop bit
no flow control
IGS-803SM(-E) switches use a command line interface (CLI)
through the serial port. Once the IP address has been configured,
a web browser can be used to configure the device through a
more easy to use GUI (graphical user interface). Please refer to
the operation manual on the CDROM.
Using the provided console cable, connect the RJ-45 to the
“CONSOLE”port and the DB9 to PC COM port. Apply power to the
switch. At the "Username:" prompt, enter 'admin' (lower case, no
quotes). Just press Enter when prompted for password.
To set the IP address and subnet mask issue this command:
> ip address 1 192.168.0.250/24
(example: sets VID 1 to 192.168.0.250, subnet 255.255.255.0)
NOTE: The factory default IP address is 10.1.1.1 with mask
255.255.255.0
RJ-45 to DB-9 Signal Mapping
DB-9 (Female)
Direction
RJ-45
Signal
Pin
Pin
Signal
RXD
2
3
TXD
TXD
3
6
RXD
GND
5
5
GND
Power and Alarm
Figure 4. Terminal Block
A removable terminal block on the top panel provides both
power and alarm connections. Power can be provided through
the dual inputs from separate sources. The alarm relay contact
can be wired into an alarm circuit which senses an alarm
condition when the contact is broken. The alarm relay is normally
closed when there is no alarm condition. The alarm conditions are
user programmable through management to include power, link
faults or other fault conditions. Please note that the alarm relay
contact can only support 1A current at 24VDC. Do not apply
voltage and current that exceed these specifications.
LED Indicators
LED
Color
Definition
PWR1/
PWR2
Green
Power is connected and active at the
PWR1/PWR2 input terminal
connection.
Off
PWR1/PWR2 is not connected.
Fault
Amber
When one or more of the
programmable alarm conditions is
active.
Off
Normal operation without faults.
Alarm conditions are all disabled.
CPU ACT
Green
During normal use, this LED will be lit,
indicating a healthy condition of the
running CPU.
Ring
Master
Yellow
Lit when this unit is the 'master' in a
fiber ring and all units are configured
for u-Ring or ERPS (Ethernet Ring
Protection Switching or G.8032).
LAN
LINK/ACT
Green
The connected LAN speed is
10/100M.
Green
Blinking
Blinking when there is Ethernet
traffic.
Amber
The connected LAN speed is 1000M.
Amber
Blinking
Blinking when there is Ethernet
traffic.
Off
No Ethernet link.
FIBER
LINK/ACT
Green
The fiber link is up.
Blinking
Blinking when there is data traffic.
Off
No fiber link.
Application
Fault
Figure 5. Alarm Relay Circuit
Normally Closed (NC)
- 5 -
- 3 -
- 6 -
Figure 6. u-Ring Topology and Application
- 4 -
www.ctcu.com

This manual suits for next models

1

Other CTC Union Switch manuals

CTC Union IGS-1608SM-SE User manual

CTC Union

CTC Union IGS-1608SM-SE User manual

CTC Union JB230 Series User manual

CTC Union

CTC Union JB230 Series User manual

CTC Union IGS-800C-8PH User manual

CTC Union

CTC Union IGS-800C-8PH User manual

CTC Union JB320 Series User manual

CTC Union

CTC Union JB320 Series User manual

CTC Union IGS-803SM-8PH24 User manual

CTC Union

CTC Union IGS-803SM-8PH24 User manual

CTC Union MX262 Series User manual

CTC Union

CTC Union MX262 Series User manual

CTC Union ITP-800A User manual

CTC Union

CTC Union ITP-800A User manual

CTC Union FSW-2104W User manual

CTC Union

CTC Union FSW-2104W User manual

CTC Union JB330 Series User manual

CTC Union

CTC Union JB330 Series User manual

CTC Union SB152 Series User manual

CTC Union

CTC Union SB152 Series User manual

CTC Union FRM220A-1000EAS/X User manual

CTC Union

CTC Union FRM220A-1000EAS/X User manual

CTC Union FSW3224 User manual

CTC Union

CTC Union FSW3224 User manual

CTC Union IGS-404SM User manual

CTC Union

CTC Union IGS-404SM User manual

CTC Union SB202 Series User manual

CTC Union

CTC Union SB202 Series User manual

CTC Union SB142 User manual

CTC Union

CTC Union SB142 User manual

CTC Union FS-802GS-8PH User manual

CTC Union

CTC Union FS-802GS-8PH User manual

CTC Union SB142 User manual

CTC Union

CTC Union SB142 User manual

CTC Union ITP-1204GTM-12PHE User manual

CTC Union

CTC Union ITP-1204GTM-12PHE User manual

CTC Union IGS+803SM-8PH User manual

CTC Union

CTC Union IGS+803SM-8PH User manual

CTC Union JB210 Series User manual

CTC Union

CTC Union JB210 Series User manual

CTC Union IGS-401F User manual

CTC Union

CTC Union IGS-401F User manual

CTC Union ITP-800-8PH24 User manual

CTC Union

CTC Union ITP-800-8PH24 User manual

CTC Union JB120 Series User manual

CTC Union

CTC Union JB120 Series User manual

CTC Union SB102 Series User manual

CTC Union

CTC Union SB102 Series User manual

Popular Switch manuals by other brands

Aeon Labs AEOR Series quick start guide

Aeon Labs

Aeon Labs AEOR Series quick start guide

FS S5500-48T8SP Configuration guide

FS

FS S5500-48T8SP Configuration guide

Exsys EX-1170HMVS manual

Exsys

Exsys EX-1170HMVS manual

ACME CA-416 quick start guide

ACME

ACME CA-416 quick start guide

Orei HDA-934 user manual

Orei

Orei HDA-934 user manual

Lantronix SM24TBT2DPA quick start guide

Lantronix

Lantronix SM24TBT2DPA quick start guide

FS S3200 Series quick start guide

FS

FS S3200 Series quick start guide

Enabling Devices 7459 user guide

Enabling Devices

Enabling Devices 7459 user guide

Ihse Draco U-Switch user manual

Ihse

Ihse Draco U-Switch user manual

PNI CS101 user manual

PNI

PNI CS101 user manual

GoMax Electronics DS-2045E-PT user manual

GoMax Electronics

GoMax Electronics DS-2045E-PT user manual

3Com 3C16950 - SuperStack II Switch 1100 user guide

3Com

3Com 3C16950 - SuperStack II Switch 1100 user guide

3Com SUPERSTACK II 2000 TR Guide

3Com

3Com SUPERSTACK II 2000 TR Guide

ZyXEL Communications GS-105S quick start guide

ZyXEL Communications

ZyXEL Communications GS-105S quick start guide

CURB CURB Quick Start Install Guide

CURB

CURB CURB Quick Start Install Guide

ATEN US221A specification

ATEN

ATEN US221A specification

SCHUNK MMS 22-PI1-EX Assembly and operating manual

SCHUNK

SCHUNK MMS 22-PI1-EX Assembly and operating manual

Dr. A. Kuntze PH-T manual

Dr. A. Kuntze

Dr. A. Kuntze PH-T manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.