manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CTC Union
  6. •
  7. Switch
  8. •
  9. CTC Union IFS-802GS-8PH User manual

CTC Union IFS-802GS-8PH User manual

This manual suits for next models

1

Other CTC Union Switch manuals

CTC Union IFS-803GSM User manual

CTC Union

CTC Union IFS-803GSM User manual

CTC Union GSW-3208M1 User manual

CTC Union

CTC Union GSW-3208M1 User manual

CTC Union SB152 Series User manual

CTC Union

CTC Union SB152 Series User manual

CTC Union FRM220-10/100AS-2 User manual

CTC Union

CTC Union FRM220-10/100AS-2 User manual

CTC Union IGS-404SM User manual

CTC Union

CTC Union IGS-404SM User manual

CTC Union JB110 Series User manual

CTC Union

CTC Union JB110 Series User manual

CTC Union JB130 Series User manual

CTC Union

CTC Union JB130 Series User manual

CTC Union GSW-1005MS User manual

CTC Union

CTC Union GSW-1005MS User manual

CTC Union IGS-803SM User manual

CTC Union

CTC Union IGS-803SM User manual

CTC Union JB210 Series User manual

CTC Union

CTC Union JB210 Series User manual

CTC Union TSB6000 Series User manual

CTC Union

CTC Union TSB6000 Series User manual

CTC Union IFS?500 User manual

CTC Union

CTC Union IFS?500 User manual

CTC Union IFS?402F User manual

CTC Union

CTC Union IFS?402F User manual

CTC Union IGS?401F?4PH24 User manual

CTC Union

CTC Union IGS?401F?4PH24 User manual

CTC Union SB142 User manual

CTC Union

CTC Union SB142 User manual

CTC Union IGS+803SM-8PH User manual

CTC Union

CTC Union IGS+803SM-8PH User manual

CTC Union IFS-803GSM-8PH24 User manual

CTC Union

CTC Union IFS-803GSM-8PH24 User manual

CTC Union IQS-402XSM-4PH User manual

CTC Union

CTC Union IQS-402XSM-4PH User manual

CTC Union FRM220A-1000EAS/X User manual

CTC Union

CTC Union FRM220A-1000EAS/X User manual

CTC Union IFS?401F User manual

CTC Union

CTC Union IFS?401F User manual

CTC Union GSW-3208M User manual

CTC Union

CTC Union GSW-3208M User manual

CTC Union IGS-803SM-8PH24 User manual

CTC Union

CTC Union IGS-803SM-8PH24 User manual

CTC Union GSW-1005MS User manual

CTC Union

CTC Union GSW-1005MS User manual

CTC Union ITP-800A User manual

CTC Union

CTC Union ITP-800A User manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Application
Figure 9. Ethernet Switch Transmission
CTC Union Technologies Co., Ltd.
Far Eastern Vienna Technology Center
(Neihu Technology Park)
8F, No. 60 Zhouzi St., Neihu District, Taipei 114
Taiwan
T+886-2-26591021
F+886-2-26590237
E[email protected]
© 2015 CTC Union Technologies Co., Ltd.
All trademarks are the property of their respective owners.
Technical information in this document is subject to change without notice.
Introduction
IFS-802GS-8PH & IFS-802GS-8PHE are unmanaged industrial grade
Fast Ethernet PoE switches that provide stable and reliable Ethernet
transmission. Housed in rugged DIN rail or wall mountable enclosures,
these switches are designed for harsh environments, such as industrial
networking and intelligent transportation systems (ITS) and are also
suitable for many military and utility market applications where
environmental conditions exceed commercial product specifications.
Standard operating temperature range models (-10°C~60°C) and wide
operating temperature range models (-40°C~75°C) fulfill the special
needs of industrial automation applications.
Package List
IFS-802GS-8PH(E) Device
Protective caps for SFP slots
Quick installation guide
Din rail with screws
Wall mount bracket with screws
Terminal block
Features
Redundant dual 48VDC inputs (44~57VDC)
IP30 rugged metal housing and fanless design
8-port IEEE802.3at/af PoE output (30W per port)
Maximum PoE output power budget 240W
Wide temperature range -40°C~75°C (IFS-802GS-8PHE)
CE, FCC, EN50121-4 Rail traffic
Industrial grade EN61000-6-2 EMS and EN61000-6-4 EMI
Specifications
Ethernet Interface
8 x RJ-45 (shielded) ports
Speed: 10/100M
Duplex: Full/Half (Auto-negotiation per IEEE802.3u)
Auto MDI/MDI-X function
Optical
2 x SFP slots
Speed: 1000M
Switch
Store & Forward Switch
Supports IEEE802.3x Flow Control
Switching Fabric: 5.6Gbps non-blocking
Standards: IEEE802.3, 802.3u, 802.3x, 802.3z
MAC Table: 8K
Packet Buffer Size: 1Mbits
Quick Installation Guide
IFS-802GS-8PH
IFS-802GS-8PHE
8 x 10/100Base-TX + 2 x 1000Base-X SFP with 8 High Power PoE
Switch (Hardened)
Specifications (cont.)
Power over Ethernet
8 x PoE-enabled ports, Alternate A Mode
Support IEEE802.3af 15.4watts PoE per port
Support IEEE802.3at 30watts PoE+ per port (240W budget)
Positive (VCC+) pins 1,2; Negative (VCC-) pins 3,6; Data pins 1, 2, 3, 6
Power
Absolute Input Range: 44~57VDC (50~57VDC input is recommended
for IEEE802.3at 30W applications)
Reverse Polarity Protection: Yes
Dual Power Inputs: Yes
Connector: Removable terminal block
Consumption:
Input
Voltage
Total Power
Consumption
Device Power
Consumption
PoE Power
Budget
48VDC
251W
5.2W
240W
Mechanical
Water & Dust Proof: IP30 Protection
Dimensions: 106mm (D) x 72mm (W) x 152mm (H)
Mounting: DIN-Rail or Wall Mounting (kits included)
Weight: 765 g
Environmental
Operating Temperature :
-10°C~60°C (IFS-802GS-8PH), -40°C~75°C (IFS-802GS-8PHE)
Storage Temperature: -40°C~85°C
Humidity: 5%~95% (non-condensing)
Certifications
EMC: CE
EMI (Electromagnetic Interference): FCC, FCC Part 15 Subpart B Class
A, CE EN55022 Class A
Railway Traffic: EN50121-4
Immunity for Heavy Industrial Environment: EN61000-6-2
Emission for Heavy Industrial Environment: EN61000-6-4
EMS (Electromagnetic Susceptibility) Protection Level:
EN61000-4-2 (ESD) Level 3, Criteria B
EN61000-4-3 (RS) Level 3, Criteria A
EN61000-4-4 (Burst) Level 3, Criteria A
EN61000-4-5 (Surge) Level 3, Criteria B
EN61000-4-6 (CS) Level 3, Criteria A
EN61000-4-8 (PFMF, Magnetic Field) Field Strength: 300A/m,
Criteria A
Safety: UL60950-1 (Pending) ●Shock: EN60068-2-27
Freefall: EN60068-2-32 ●Vibration: EN60068-2-6
MTBF (MIL-HDBK-217): 400,469 Hours
[email protected]
To download this QIG or a more complete user manual, please visit
http://www.ctcu.com/Industrial/
V1.0
- 2-
- 1-
www.ctcu.com
- 7 -
Panels
Index
No.
Description
Index
No.
Description
1
SFP slot 1~2
6
PoE LEDs
2
Fast Ethernet port
1~8
7
Terminal block for power
inputs & alarm relay
3
Power, SFP, Fault
LEDs
8
Grounding connection
4
Fast Ethernet
LNK/Act LED
9
DIP switch
5
Fast Ethernet 100M LED
LAN and Fiber Connection
IFS-802GS-8PH(E) PoE switches have 8 electrical LAN ports (labeled
1~8) and 2 SFP-based fiber ports (labeled SFP 1~2) on the front panel.
The LAN ports utilize shielded RJ-45 connectors that support 10/100M;
while the fiber SFP ports support 1000M.
PoE Ports
All 8 LAN ports support PoE (Power over Ethernet) per IEEE802.3af
(15.4W) or IEEE802.3at (30W) for connection to standard PoE PD (Power
Devices) such as IP Cameras, Access Points, IP Phones, Digital Signage.
Using switches with PoE function can eliminate the need to run separate
power to these devices thereby simplifying deployment and reducing
expenses.
The LAN ports may also connect to any non-PoE device for normal
Ethernet transmission without any damage to the non-PoE device or to
this device.
Earth Ground Connection
An earth ground connector is provided on the top panel (See Figure 2)
with an earth ground sign next to it. Grounding the device can help to
release leakage of electricity to the earth safely so as to reduce injuries
from electromagnetic interference (EMI).
Prior to connecting to the power, it is important to connect the
ground wire to the earth. Follow steps below to install ground wire:
1. Remove the grounding screw.
2. Attach the grounding screw to the ring
terminal of the grounding cable. Make
sure that the grounding cable is long
enough to reach the earth.
3. Use a screwdriver to fasten the
grounding screw.
LED Indicators
LED
Color
Status
Definition
PWR1/
PWR2
Green
On
Power is connected and active at the
PWR1/PWR2 input terminal
connection.
Off
PWR1/PWR2 is not connected.
Fault
Amber
On
One of the power inputs has fault
condition (DIP No. 1 must be turned
OFF).
Off
Normal operation without faults.
Alarm conditions are all disabled.
LAN
LNK/
ACT
Green
On
Ethernet link is up.
Blinking
Blinking when there is Ethernet
traffic.
Off
No Ethernet link.
100M
Yellow
On
The connected LAN speed is 100M.
Off
LAN speed is 10M.
SFP1/
SFP2
Green
On
The fiber SFP link is up.
Blinking
Blinking when there is data traffic.
Off
No fiber link.
PoE
Green
On
The respective LAN port has
successfully negotiated PoE and is
supplying output power to the
remote connected PD.
Blinking
One of the PoE faults (overload,
short circuit, port failure at startup)
occurs.
Off
PD is not connected or output power
is not provided.
RJ-45 Ethernet Port Pinouts
Figure 3. RJ-45 Ethernet Port Pinouts
RJ-45 Ethernet & PoE Pin Assignments
Pin
No.
RJ-45 Ethernet
10/100Base-TX
PoE Output
1
RX+
V+
2
RX-
V+
3
TX+
V-
4
-
5
-
6
TX-
V-
7
-
8
-
Power and Alarm
A removable terminal block on the top panel (See Figure 2) provides
both power and alarm connections. Power can be provided through the
dual inputs from separate sources. The alarm relay contact can be wired
into an alarm circuit which senses an alarm condition when the contact
is broken. The alarm relay is normally closed when there is no alarm
condition. Please note that the alarm relay contact can only support 1A
current at 24VDC. Do not apply voltage and current that exceed these
specifications.
DIP Switch
IFS-802-8PH(-E) switches use a 2-pole DIP switch for configuration.
Each pole of the switch has the following functions:
DIP
No.
Status
Function
Description
1
OFF*
Alarm
Enable
Provide alarm relay and fault LED
indication if there is a power failure in
one supply.
ON
Alarm
Disable
Disable alarm relay and fault LED if
there is a power failure in one supply.
Connecting to a single power source,
place this switch ON to disable alarm.
2
Reserved for future use.
* The default setting.
Installation
IFS-802GS-8PH(E) come with both wall mount and DIN rail
hardware brackets. When installing the DIN rail bracket, be sure
to correctly align the orientation pin.
Figure 5. DIN Rail Figure 6. Wall Mount
IFS-802GS-8PH(E) with DIN Rail bracket have a steel spring in
the upper rail of the bracket. This spring is compressed for
mounting and un-mounting by applying downward force.
Figure 7. Mounting Figure 8. Un-mounting
Fault
Figure 4. Alarm Relay Circuit
Normally Closed (NC)
- 4 -
- 5 -
- 6 -
www.ctcu.com
1
2
3
4
7
8
7
9
6
8
5
Figure 1. Front Panel
Figure 2. Top Panel
- 3 -