SECTION 3 | MAINTENANCE CHECKLISTS
3.1 | PRESTART INSPECTION CHECKLIST
Y-Yes/Acceptable N-No/Unacceptable R-Repaired YNR
VISUAL INSPECTIONS
Check that there are no damaged, dented, or bent structural members ڧڧڧ
There are no loose or missing parts. ڧڧڧ
Check that warning and instructional labels are legible and secure. Ensure the load capacity is clearly
marked.
ڧڧڧ
Check the platform rails and safety gate for damage. ڧڧڧ
Platform and base controls are not missing, damaged, frayed, or disconnected. ڧڧڧ
Hydraulic hoses are not torn or loose, and there are no leaks. Check that hoses and cables have no
worn areas or chafing. ڧڧڧ
Check the tires for damage. ڧڧڧ
Check that all snap rings are secure in grooves on pivot pins. ڧڧڧ
FUNCTIONAL TESTS
Gate closes automatically and latches (alignment can be adjusted with screw-on toe board or railing). ڧڧڧ
Platform Controls: Check all switches and push buttons for proper operation.
Emergency Stop (Stops all movement) ڧڧڧ
Up/Down Controls (Elevates, Lowers, Enable button must be pressed). ڧڧڧ
Base Controls: Check all switches and push buttons for proper operation.
Emergency Stop (Stops all movement) ڧڧڧ
Key Switch (Selects Platform Control, Ground Control, or O). ڧڧڧ
Alarm (Not damaged, sounds for descent). ڧڧڧ
Up/Down Rocker Switch (Elevates/Lowers). ڧڧڧ
Wheels: Front and rear wheels rotate freely. ڧڧڧ
Brakes engage and hold when platform is elevated. ڧڧڧ
Date: Inspected by:
Model: Serial Number:
• Keep inspection records up-to-date.
• Record and report all discrepancies to your supervisor.
• A dirty machine cannot be properly inspected.
THIS CHECKLIST MUST BE USED AT THE BEGINNING OF EACH SHIFT OR
AFTER EVERY SIX TO EIGHT HOURS OF USE. FAILURE TO DO SO COULD
AFFECT THE SAFETY OF THE OPERATOR.
Pre-start Inspection (Push-Around Models)
WARNING
MAINTENANCE & TROUBLESHOOTING
HBP527
SUPO724
REV B
12
SECTION 3 | MAINTENANCE CHECKLISTS
3.2 | PREDELIVERY / FREQUENT / ANNUAL INSPECTION CHECKLIST
Model: Serial Number:
• Check each item listed below.
• Use proper operating, service, and maintenance manual for specific information and settings
• If an item is found to be unacceptable make the necessary repairs and check the “repaired” box.
• When all items are “acceptable”, the unit is ready for service.
• If an item is found to be unacceptable, make the necessary repairs and check the “repaired” box. When all
items are “acceptable,” the unit is ready for service.
Y — Yes/Acceptable N — No/Unacceptable R — Repaired
Date: Inspected by:
AERIAL PLATFORMS SHALL BE INSPECTED, SERVICED, AND ADJUSTED TO
MANUFACTURER’S REQUIREMENTS BY A QUALIFIED MECHANIC PRIOR TO
EACH SALE, LEASE, OR RENTAL, AND EVERY 3 MONTHS OR 150 HOURS,
WHICHEVER COMES FIRST, AND ANNUALLY.
BASE: Y N R PLATFORM: Y N R
Inspect slide tracks for damage □□□
All rails in place/secure □□□
All frame bolts tight □□□
No bent rails □□□
Pump Secure □□□
No broken welds □□□
DC motor secure □□□
Platform power outlet safe/working (if installed) □□□
Battery Hold Downs Secure □□□
Entrance gate closes freely □□□
Batteries Fully Charged □□□
Cables in place/secure □□□
Counterweights secured □□□
Functions:
Wheels: Grease casters □□□
Elevate/Lower Operational □□□
Wheels: Bolts/Nuts Tight □□□
Master Power Switch Breaks Circuits □□□
Maintenance Locks: Pins storage location □□□
Emergency Stop Breaks Circuits □□□
All Shields/Guards in place □□□
Emergency Down Operational □□□
Hydraulic Oil Level □□□
Motion Alarms Functional □□□
Check all hydraulic hoses for leaks □□□
Brakes: Operational □□□
Check all hydraulic fittings for leaks □□□
Bubble Level in Place □□□
SCISSORS
When beginning to elevate, overload light and alarm
activate. Then, if not overloaded, allows elevation to
continue, and light and alarm stop.
□□□
No Broken Welds □□□
When overloaded, platform stops elevating. □□□
Ret. Rings Secure on Pivots □□□
Check battery Voltage: <12.5V, charge. □□□
No Bent Beam Members □□□
WIRING / OTHER:
All rollers turn freely □□□
Switches secure □□□
DECALS: Contactor(s) secure □□□
Legibility □□□
Tight on terminals (no loose wiring) □□□
Correct capacity noted □□□
Operator / Service Manual Included □□□
Proper placement quantity □□□
Battery Charger Secure / Operational □□□
COMMENTS:
CAUTION
MAINTENANCE & TROUBLESHOOTING
HBP527
SUPO724
REV B
13