dacell DN-10W User manual

Ver 203A
DIGITAL INDICATOR
USER’S MANUAL
DN-10W (VER 203A)
DN-20W (VER 203A)
DN-25W (VER 203A)
DN-27W (VER 203A)
DN-30W (VER 203A)
DN-50W (VER 203A)
DN-70,80 (VER 203A)
DACELL CO.,LTD.
Address : 37-9 Cheoksan 5gili, Nami-Myeon,Seowon-gu,
Cheongju-city, Chung-buk
TEL : 043-260-2242
FAX : 043-260-2245
http://www.dacell.com
E-Mail : info@dacell.com

1
Contents
1. Features ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 2
2. Attention ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 3
2-1. Attention for installation ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 3
2-2. Attention for use ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 3
3. Specification ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 4
4. Front Panel ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 6
5. Rear Panel ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 8
6. Wiring Diagram ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 11
7. Components & Function ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 14
7-1. How to use Hold mode ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 14
7-2. How to use comparison output function ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 15
8. Setting mode ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 18
8-1. Types of Setting mode & Set-up ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 18
8-2. Function mode (Function Set-up) ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 19
1)
DN-10W, DN-20W, DN-25W, DN-27W, DN-50W, DN-70,80 function set-up
⋅⋅⋅ 19
2) DN-30W
function set-up
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 20
3) 3) How to change the REALY setting ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 21
8-3. Function list ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 22
8-4. Digital calibration (Calibration by sensor output value) ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 31
8-5. Actual load calibrate ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 3 4
8-6. Data Back-up & Restore ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 38
8-7. Lock Set-up ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 39
9. Product Inspection ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 40
10. OPTION
10-1. BCD output Interface ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 42
10-2. Serial communication ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 44
1) Wiring ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 44
2) Port ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 44
10-3. Protocol ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 45
1) Standard protocol ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 45
2) Modbus RTU protocol ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 46

2
1. Features
We thank you for using our product. Please refer to this manual or contact our office if
you find any problems during using our product.
This product is an indicator that emplifies the micro voltage signals from each sensor
and display in digital. It is mainly used to measure physical quantities of the items using
strain guage such as loadcell, pressure sensor, displacement sensor and torque sensor.
This product has the following special features.
1-1. Calibration method
Calibration by actual load (standard weight) and calibration by rated output of sensor.
1-2. Hold and Peak Hold
You can choose peak hold and sample hold as per your need.
1-3. Comparison Output
You can do set-up the maxium and lower limit value by the keys on the front panel
and print with contact point signal of the rear panel.
1-4. Data Back-up
All the set-up values will be memorized on the flash memory so the inputted data can
be saved and no need to do the re-setting even in case of the interruption of the
electric power or power disconnection.
1-5. Watch dog
This function is for automatic reset in case the system is stopped due to the external
factors such as noise.
1-6. Option
•OP-01 : Parallel BCD output
•OP-02 : RS232C Interface (basic installation)
•OP-03 : RS485 Interface
•OP-10 : Power DC24V 0.3A
Additional optional RS232C, RS485, or BCD outputs are available, and our standard
protocol and Modbus RTU protocol can be selected from Function settings.
1-7. Power
AC 90 ~ 240V 50/60Hz 8VA (Option : DC24V 0.3A)
Model DN-70,80 Power: DC24V 0.2A

3
2. Attention
For the efficient and safe use, please carefully read and be fully aware of the following
details before using this product.
It is strictly forbidden to use this product for any other purpose of use or to attempt to
make any alteration on this product.
2-1. Attention for installation
•Please keep it out of wet places.
•Do not set it up near vibration & impulse, high temperature and humidity.
Keep it out of the direct rays of the sun. Set it up where there is less dust, and Keep it
out of direct air including salt and ion.
•Do not use when there is inflammable gas or heavy machinery, and smog.
•Ground earth-terminal ( ).
•Make wire separately from power system wiring and noise wiring.
•Make sure the use of 4 line sealed cable as a sensor cable.
Too long cable leads to measurement error due to wiring resistance (around
10meters).
2-2. Attention for use
•During calibration, Do not input free-load state and real-weight load until it becomes
stable. Pressing Enter Key in unstable condition leads to calibration error.
•Do not press any Key in use at one's discretion. Please refer to 7. Setting-up mode
for the function and method of Key.

4
3. Specification
Spec. Model DN-10W DN-50W DN-30W DN-70
Available sensor Strain Gauge sensor PROXIMITY
SENSOR
Strain Gauge
sensor
SIGNAL 0.5 ~ 3mV/V pulse 0.5 ~ 3mV/V
EXCITATION DC 5V 70mA 12V DC 5V 70mA
Upper limit Display -19999 ~ +99999 60pulse/1circle
:0~13000 13kHz
-19999 ~
+99999
A/D Converter 24bit 200
times /s
24bit 1000
times /s
24bit 200
times /sec
D/A Converter 16bit
Temperature
Characteristic
Zero ±10ppm/℃
Span ±10ppm/℃
Measured value display 7 segment 5 Digit, Height 14mm (DN-70 Height8mm )
Status display LED Red LED 6PCS Red LED
5PCS
Key Switch 4pcs
Comparison output 4 Relay 4 Relay
Contact Capacity AC 250V 3A (more than 100,000)
Analog out DC 0~±10V or 4~20mA (Selective use) Opt i o n
Temperature Range -10℃~ 60℃, 80% less than 80% RH (no dewing.)
Sizes 96 × 48 × 128 mm (W × H × D) 48 × 48 ×
128mm
Panel cutting size 91.5 × 44.5 mm 45.5 × 45.5
mm
Weight : about 500g : about 280g
Power supply AC 90 ~ 240V 8VA (DC24V 0.3A) DC24V 0.2A
Option
OP-02 : RS232C (basic installation), OP-
03 : RS485
Interface
OP-01 : Parallel BCD output
OP-10 : Power DC24V 0.3A OP-06 DC 0~±
10V or 4~20mA
OP-14: Signal 5mV/V
OP-15: Signal10mV/V

5
Spec. Model
DN-20W
DN-25W
DN-27W
DN-80
Available sensor
Voltage, current
sensor
Potentiometer
HBT(Half type)
(Option : LVDT)
Differential
trans torque
sensor
Potentiometer
SIGNAL DC0~10V or 4~20mA
(Option : ±10V) AC0~2Vrms 0.5~2mV/V DC0~10V
EXCITATION
DC10V or 24V 60mA
(Option : ±15V
60mA)
AC2Vrms 5kHz DC5V 70mA
MAX. Display -19999 ~ +99999
A/D Converter 24bit 200times/sec
D/A Converter 16bit
Temperature
Characteristic
ZERO 0.5㎶/℃
SPAN 50pm/℃
Measured value
display 7 segment 5 Digit, Height 14mm (DN-70 Height8 mm)
Key Switch 4 PCS
Status display LED Red LED 6PCS Red LED 5PCS
Comparison output
4 Relay 3 Relay
Contact Capacity
Contact Capacity
AC250V 3A (More than 100000)
Analog out
DC0~10V or 4~20mA
DC0~±10V or 4~20mA Option
Temperature
range for use -10℃~ 60, >80% RH (No dewing)
Sizes 96 × 48 × 128 mm (W × H × D) 48×48×128 mm
(W×H×D)
Panel cutting size
91.5 × 44.5 mm 45.5 × 45.5 mm
Weight About 500g About 280g
Power supply AC 90 ~ 240V 8VA (Option : DC24V 0.3A) DC24V 0.2A
OPTION
OP-02 : RS232C (basic installation), OP-03 : RS485 Interface
OP
-01 : Parallel BCD output
OP
-10 : Power DC24V 0.3A OP-06 : Analog output
DC0~±10V or 4~20mA
OP
-12:sensor input ±15V
OP
-13:sensor signal ±10V
OP-11 : LVDT -

6
4. Front panel
⑴DN-10W, DN-20W, DN-25W, DN-27W, DN-30W, DN-50W
①comparison output Indication LED: The LED lights up when the Relay is in contact
output state.
②HOLD Indication LED: This LED will be lighted when the measured value is on Hold.
③MOD : Measured value stable (on), unstable (off) indication
④Measured value Indication: It indicates the measured value and each setting value.
⑤
Measruing Mode : Once this Key is pressed for more than 1 second, the current
measuring value will be Zero (0) and the Analog output will be 0V (4mA) as well.
SET-UP Mode : Once this is pressed on the Function Mode, you will return to the
measuring mode.
⑥
Measuring Mode : Once this Key is pressed, the lower limit setting value will be
displayed and this value also can be changed.
SET-UP Mode : The location of row for the number flickering can be moved.
⑦
Measuring Mode : Once this Key is pressed, the upper limit setting value will be
displayed and the value can be changed.
SET-UP Mode : The flickering number will be increased by 1 and 1.
⑧
Measuring Mode : Once this Key is pressed, HOLD will be selected and once this key
is pressed again, HOLD will be cancelled.
SET-UP Mode : Save each set-up value.
※Measuring Mode : The state in which the current measurement is being displayed
※SET-UP Mode: State of entering function menu with key operation

7
⑵DN-70, DN-80
①HI, LO Indication LED: LED will be lighted when measured value exceeds the setting
value.
⑥HOLD Indication LED: This LED will be lighted when the measured value is on Hold.
⑦MOD : Measured value stable (on), unstable (off) indication
④Measured value Indication: It indicates the measured value and each setting value.
⑤
Measruing Mode : Once this Key is pressed for more than 1 second, the current
measuring value will be Zero (0) and the Analog output will be 0V (4mA) as well.
SET-UP Mode : Once this is pressed on the Function Set-up Mode, you will
return to the measuring mode.
⑥
Measuring Mode : Once this Key is pressed, the lower limit setting value will be
displayed and this value also can be changed.
SET-UP Mode : The location of row for the number flickering can be moved.
⑦
Measuring Mode : Once this Key is pressed, the upper limit setting value will be
displayed and the value can be changed.
SET-UP Mode : The flickering number will be increased by 1 and 1.
⑧
Measuring Mode : Once this Key is pressed, HOLD will be selected and once this key
is pressed again, HOLD will be cancelled.
SET-UP Mode : Save each set-up value.

8
5. Rear panel
⑴DN-10W, DN-20W, DN-25W, DN-27W, DN-30W, DN-50W
Please check the location of terminal and its use. While the projected button is being
pressed, please insert the cable into the lower hole completely. As soon as you release
the button, the connection will be completed. At the point, please slightly pull the calbe
and check whether the cable is come off or not.
(The most suitable calbe is Φ0.5~1. Linking cable must be brazing or used with 1
terminal)
①AC IN : Main Power Supply Wiring Terminal
②: Ground Terminal (as an independent ground connection.)
③OUT : Analog (DC 0 ~10V/DC 4 ~ 20mA) Output Terminal
④EXC+ : Sensor Supply Voltage + Connection Terminal
⑤EXC- : Sensor Supply Voltage + Connection Terminal
⑥SIG+ : Sensor Ouput Signal + Connection Terminal
⑦SIG- : Sensor Output Signal –Connection Terminal
⑧SHI : SHIELD connection terminal of sensor
⑨GND, TXD, RXD : RS232C SERIAL INTERFACE (RS485 : TXD →TX+, RXD →TX-)
⑩INC : External Input Common Terminal
⑪IN1 : External HOLD Input Terminal
⑫IN2 : External ZERO Input Terminal
⑬IN3 : External printer signal Input Terminal (when PT-100 use)
⑭IN4 : No use
⑮RYC : RELAY Output Common Terminal
⑯RY1 : RELAY 1(Lower Limit) Output Terminal

9
○
17E
ARY2: RELAY2 (Upper Limit) Output Terminal
A○
18E
ARY3: RELAY3( Normal) Output Terminal (OK )
A○
19E
ARY4: RELAY 4 Output Terminal
A○
20E
ASW1, 2 :
•DN-10W, DN-25W, DN-27W, DN-30W, DN-50W : NC
•DN-20W :
Sensor supply voltage setting Sensor output signal setting
DC10V DC24V 0 ~ 10V 4 ~ 20mA
SW1 OFF ON -
SW2 - OFF ON
※When use Potentiometer (Model LPS,LPM) : SW1 and SW2 OFF
A○
21E
AFG : Frame ground terminal
⑵DN-70, DN-80
Please check the location of terminal and its use. While the projected button is being
pressed, please insert the cable into the lower hole completely. As soon as you release
the button, the connection will be completed. At the point, please slightly pull the calbe
and check whether the cable is come off or not.
(The most suitable calbe is Φ0.5~1. Linking cable must be brazing or used with 1
terminal)
①24V : DC24V (Main Power)
②EXC+ : Sensor Supply Voltage + Connection Terminal
③EXC- : Sensor Supply Voltage + Connection Terminal

10
④SIG+ : Sensor Ouput Signal + Connection Terminal
⑤SIG- : Sensor Output Signal –Connection Terminal
⑥GND : SHIELD connection terminal of sensor
⑦: Ground Terminal (as an independent ground connection.)
⑧INC : External Input Common Terminal
⑨IN1 : External HOLD Input Terminal
⑩IN2 : External ZERO Input Terminal
⑪RYC : RELAY Common Terminal
⑫RY1 : RELAY1(Lower Limit) Output Terminal
⑬RY2 : RELAY2 (Normal) Output Terminal (OK )
⑭RY3 : RELAY3 (Upper Limit) Output Terminal
※OPTION
⑮GND, TXD, RXD : RS232C SERIAL INTERFACE Terminal
(RS485 : TXD -> TX+, RXD -> TX-)
○
16E
AGND, OUT : Analog out Terminal (DC ±10V or DC 4~20mA)
◀Attention▶
1. When wiring, please pull out the power plug. (Main power supply)
2. Please use the thick calbe for ground terminal ( ) so that you can avoid any trouble
due to the impulse voltage or surge. If possible, please keep it as an independent
ground.
(This must be used in the area with heavy noise. If the ground is made with other
device, it will be affected by noise.)
3. Please check the function of the terminal before you do the wiring so that you can
prevent any malfunction in advance.
4. Manufacture will be relieved of its responsibility for any damge or injury due to the
disassembly and alteration made without any agreement. Also, no A/S will be made.

11
6. Wiring Diagram
⑴DN-10W, DN-50W
⑵DN-20W

12
⑶DN-25W
⑷DN-27W
⑸DN-30W

13
⑹DN-70, DN-80
⑺Example - External Input PLC Connection

14
7. Components & Function
7-1. How to use Hold mode
Hold mode is largely divided into Peak Hold and Sample Hold. Please select Peak or
Sample. To input Hold, you can use Hold key on the front panel or external input. For
the operation method, please refer to the drawing below.
1) Peak Hold : To Hold the maxium value among the measured values.
Peak hold mode : It is to hold and display the maximum value of (+) direction.
Absolute peak hold mode : It is to hold and display the maximum value of the absolute
value (+/-).
2) Sample hold : It is to hold and display the value at the time of Hold signal input
among the measured values.
On
Off
On
Off
On
off
①−: sensor input value
②
−
: Display value &
analog output value
Measured value
time
①
②
Measured value
time
①
②
<Peak HOLD> <Sample HOLD>
Front panel HOLD LED
E
xternal HOLD input termanal
Front panel HOLD Key

15
7-2. How to use comparison ouput function
For comparison output function, there are 4 different modes such as Decision, High
limit, Low limit, Low&High limit. It displays through the relay of rear panel comparing
each setup value.
On limit mode, Hysteresis can be used.
To set up the setting value, please use the key on the front panel..(page21)
1) Decision mode : Measured Value ≤Lower limit setup value ⇒RY1 ON (Low)
Measured Value ≥Upper limit setup value ⇒RY3ON (Hi)
Lower limit setup value < Measured value < Upper limit setup value ⇒RY2 ON (OK)
2) High limit mode : Measured Value ≥RY1 setup value ⇒RY1 ON
Measured Value ≥RY2 setup value ⇒RY2 ON
Measured Value ≥RY3 setup value ⇒RY3 ON
Measured Value ≥RY4 setup value ⇒RY4 ON
Measured Value < RY1 setup value – Hysteresis value⇒RY1 OFF
Measured Value< RY2 setup value - Hysteresis value⇒RY2 OFF
Measured Value < RY3 setup value – Hysteresis value⇒RY3 OFF
Measured Value< RY4 setup value - Hysteresis value⇒RY4 OFF
3) Low limit mode : Measured Value ≤RY1 setup value ⇒RY1 ON
Measured Value ≤RY2 setup value ⇒RY2 ON
Measured Value ≤RY3 setup value ⇒RY3 ON
Measured Value ≤RY4 setup value ⇒RY4 ON
Measured Value > RY1 setup value + Hysteresis value⇒RY1 OFF
Measured Value > RY2 setup value + Hysteresis value⇒RY2 OFF
Measured Value > RY3 setup value + Hysteresis value⇒RY3 OFF
Measured Value > RY4 setup value + Hysteresis value⇒RY4 OFF
4) Low & High limit mode
Measured Value ≤RY1 setup value ⇒RY1 ON
Measured Value ≤RY2 setup value ⇒RY2 ON
Measured Value ≥RY3 setup value ⇒RY3 ON
Measured Value ≥RY4 setup value ⇒RY4 ON
Measured Value > RY1 setup value + Hysteresis value ⇒RY1 OFF
Measured Value > RY2 setup value + Hysteresis value ⇒RY2 OFF
Measured Value < RY3 setup value - Hysteresis value ⇒RY3 OFF
Measured Value < RY4 setup value - Hysteresis value ⇒RY4 OFF

16

17
* Note) In Function mode, if the value of F-13 is set the Base Offset (page26) , the
comparative output operates as follows.
1) Decision mode : Measured Value ≤(Offset-Lower limit setup value) ⇒RY1 ON (Low)
Measured Value ≥(Offset +Upper limit setup value) ⇒RY3ON (Hi)
(Offset -Lower limit setup value) < Measured value < (Offset +Upper limit setup value) ⇒RY2 ON (OK)
2) High limit mode : Measured Value ≥(Offset +RY1 setup value) ⇒RY1 ON
Measured Value ≥(Offset +RY2 setup value) ⇒RY2 ON
Measured Value ≥(Offset +RY3 setup value) ⇒RY3 ON
Measured Value ≥(Offset +RY4 setup value) ⇒RY4 ON
Measured Value <(Offset + RY1 setup value) – Hysteresis value⇒RY1 OFF
Measured Value< (Offset +RY2 setup value) - Hysteresis value⇒RY2 OFF
Measured Value < (Offset +RY3 setup value) – Hysteresis value⇒RY3 OFF
Measured Value< (Offset +RY4 setup value) - Hysteresis value⇒RY4OFF
3) Low limit mode : Measured Value ≤(Offset +RY1 setup value) ⇒RY1 ON
Measured Value ≤(Offset +RY2 setup value) ⇒RY2 ON
Measured Value ≤(Offset +RY3 setup value) ⇒RY3 ON
Measured Value ≤(Offset +RY4 setup value) ⇒RY4 ON
Measured Value > (Offset +RY1 setup value) + Hysteresis value⇒RY1 OFF
Measured Value > (Offset +RY2 setup value) + Hysteresis value⇒RY2 OFF
Measured Value > (Offset +RY3 setup value) + Hysteresis value⇒RY3 OFF
Measured Value > (Offset +RY4 setup value) + Hysteresis value⇒RY4 OFF
4) Low & High limit mode
Measured Value ≤(Offset +RY1 setup value) ⇒RY1 ON
Measured Value ≤(Offset +RY2 setup value) ⇒RY2 ON
Measured Value ≥(Offset +RY3 setup value) ⇒RY3 ON
Measured Value ≥(Offset +RY4 setup value) ⇒RY4 ON
Measured Value > (Offset +RY1 setup value) + Hysteresis value ⇒RY1 OFF
Measured Value > (Offset +RY2 setup value )+ Hysteresis value ⇒RY2 OFF
Measured Value <(Offset + RY3 setup value) - Hysteresis value ⇒RY3 OFF
Measured Value < (Offset +RY4 setup value) - Hysteresis value ⇒RY4 OFF

18
8. Setting Modes
8-1. Types of Setting mode & Set-up
For Setting mode, there are 3 different types of mode such as Function mode, Digital
calibration mode and Actual load calibration mode.
Mesuring mode
While key is being
Press, press key
Function mode
①
Digital calibration
mode
②
③
Actual load
calibration mode
①Function mode
Acess to each function setup mode. Please refer 8-2 function mode.
②Digital calibration mode
It is to calibrate into the sensor’
s output value. No need to prepare for the actual
load (stand weight). Please refer 8-4 how to calibrate.
③Actual load calibration mode
It is to calibrate by adding the actual load (standard weight or the load you know).
Please refer 8-5 how to calibrate.
* Measurement mode status is the status of the indicator showing the current
value.
※DN-30W can only set Function mode.
Change to key
Select by key

19
8-2. Function mode
1)
How to set function
(for DN-10W, DN-20W, DN-25W, DN-27W, DN-50W, DN-
70,80)
The setting value of Function mode (page 22~29) can be changed the key operation
below. (F-00~F-52)
Measuring mode
While key is being
Press, press key
Change to and key
Select and save by key.
Completion
This manual suits for next models
7
Table of contents
Other dacell Measuring Instrument manuals

dacell
dacell PDN-10 User manual

dacell
dacell DN-330 User manual

dacell
dacell SM110 User manual

dacell
dacell DN-10 User manual

dacell
dacell DN-15W User manual

dacell
dacell DN-300 User manual

dacell
dacell DN-40W User manual

dacell
dacell DN500N User manual

dacell
dacell DN-711A User manual

dacell
dacell DN-100 User manual
Popular Measuring Instrument manuals by other brands

Endress+Hauser
Endress+Hauser TH15 Compact instructions

LOVATO ELECTRIC
LOVATO ELECTRIC LAWN DME D121 instruction manual

CONTINENTAL CONTROL SYSTEMS
CONTINENTAL CONTROL SYSTEMS WattNode Pulse installation manual

KERN
KERN RPOMAT MSB 80 operating instructions

R&S
R&S RT-ZC20 user manual

Keller
Keller CellaTemp PX 4 Series operating instructions