• Daikin Altherma low temperature split • EHVH-C
1
2
• Heating • Daikin Altherma low temperature split
4
2 Specifications
Notes
(1) Heatloss according to EN12897
(2) DB/WB 7ºC/6ºC - LWC 35ºC (DT=5ºC)
(3) The sound pressure level is measured via a microphone at a 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment.
(4) The sound pressure level mentioned is valid for pump medium speed - 0 ESP / medium speed - nominal flow / high speed - nominal flow
(5) 15ºC-25ºC: BUH only, no heat pump operation = during commisioning
(6) Including piping + PHE + back-up heater; excluding expansion vessel
(7) Value mentioned is connection after ball valves, Connection at unit is G1-1/4 FEMALE
(8) See separate drawing for operation range
(9) For *RLQ* outdoor units \>55ºC BUH only, no heatpump operation
(10) For *RHQ* outdoor units \>50ºC BUH only, no heatpump operation
Water circuit Piping connections diameter inch G 1"1/4 (female)
Safety valve bar 3
Manometer Yes
Drain valve / fill valve Yes
Shut off valve Yes
Air purge valve Yes
Total water volume l 4.4 (6) 4.8 (6) 5.8 (6) 4.5 (6) 5.5 (6)
Safety devices Item 01 Thermal cutout (on indoor unit): 90-95ºC
PED Category Art3§3 Category I Art3§3
Most critical part Name - Plate heat exchanger -
Ps*V Bar*l - 51.0 (0.000) -
Water circuit -
Domestic hot water
side
Piping connections Cold water in / Hot
water out
inch G 1" FEMALE
Recirculation
connection
inch G 1/2" FEMALE
2-2 Electrical Specifications EHVH04S18C3V EHVH08S18C3V EHVH08S26C9W EHVH16S18C3V EHVH16S26C9W
Power supply Voltage range Min. % 10
Max. % 10
Wiring connections-
Communication cable
Quantity 3
Remark 2.5 mm²
Wiring connections-
Electric meter
Quantity 2
Wiring connections-
Preferential kWh rate
power supply
Quantity Power: 2
Wiring connections-
Domestic hot water
pump
Quantity 2
Remark Minimum 0.75 mm² (2A inrush, 1A continuous)
Wiring connections-
For connection with
R6T
Quantity 2
Remark Minimum 0.75 mm²
Wiring connections-
For connection with
A3P
Remark Select diameter & type according to national & local regulations / Voltage: 230V / Max.current: 100mA
/ Min. 0.75mm²
Wiring connections-
For connection with
M2S
Quantity 3G
Remark Select diameter & type according to national & local regulations / Voltage: 230V / Max.current: 100mA
/ Min. 0.75mm²
Wiring connections-
For connection with
bottom plate heater
Quantity 2
Remark Select diameter and type according to national and local regulations
Wiring connections-
For connection with
user interface
Quantity 2
Remark 0,75 mm² till 1,25 mm² (max length 500m)
Wiring connections-
For connection with
optional FWXV*
(demand input and
output)
Quantity 4
Remark 100 mA, minimum 0.75 mm²
Notes For more details on current & voltage range, refer to the installation manual.
2-1 Technical Specifications EHVH04S18C3V EHVH08S18C3V EHVH08S26C9W EHVH16S18C3V EHVH16S26C9W