Specifications Si01-406
8Specifications
220-230-240V 50Hz
Notes: MAX. interunit piping length: 15m
MAX. interunit height difference: 15m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Models
Indoor Units FTY25CVMA FTY35CVMA
Outdoor Units RY25CVMA RY35CVMA
Cooling Heating Cooling Heating
Capacity
kW 2.54 3.4 3.60 4.2
Btu/h 8,700 11,600 12,300 14,300
kcal/h 2,190 2,920 3,100 3,600
Moisture Removal L/h 1.2 — 1.9 —
Running Current A 5.1 5.6 7.4 7.3
Power Consumption W 900 1,100 1,360 1,340
Power Factor % 80.2-76.7-73.5 89.3-85.4-81.8 83.5-79.9-76.6 83.4-79.8-76.5
COP W/W 2.82 3.09 2.65 3.13
Piping
Connections
Liquid mm φ 6.4 φ 6.4
Gas mm φ 9.5 φ12.7
Drain mm φ18.0 φ18.0
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Indoor Units FTY25CVMA FTY35CVMA
Front Panel Color White White
Air Flow Rate m³/min
(cfm)
H 7.8 (275) 8.1 (286) 7.7 (272) 8.1 (286)
M 6.4 (226) 6.6 (233) 6.3 (222) 6.6 (233)
L 5.0 (177) 5.1 (180) 4.9 (173) 5.1 (180)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 18 18
Speed Steps 5 Steps and Auto 5 Steps and Auto
Air Direction Control Right, Left, Horizontal and Downward Right, Left, Horizontal and Downward
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current A 0.17-0.18-0.18 0.17-0.18-0.18 0.17-0.18-0.18 0.17-0.18-0.18
Power Consumption W 37-40-43 37-40-43 37-40-43 37-40-43
Power Factor % 98.9-96.6-99.5 98.9-96.6-99.5 98.9-96.6-99.5 98.9-96.6-99.5
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H×W×D) mm 273×784×195 273×784×195
Packaged Dimensions (H×W×D) mm 258×834×325 258×834×325
Weight kg 7.5 7.5
Gross Weight kg 11 11
Operation
Sound H/M/L dBA 37 / 34 / 30 37 / 33 / 30 38 / 35 / 32 38 / 35 / 31
Outdoor Units RY25CVMA RY35CVMA
Casing Color Ivory White Ivory White
Compressor
Type Hermetically Sealed Rotary Type Hermetically Sealed Rotary Type
Model RC1X26BTNT RC1X26BTNT
Motor Output W 750 750
Refrigerant
Oil
Type SUNISO 4GSD.I. SUNISO 4GSD.I.
Charge L 0.4 0.4
Refrigerant Type R22 R22
Charge kg 0.72 0.95
Air Flow Rate m³/min 28.0-29.0-30.0 25.0-25.5-26.5 26.5-27.5-28.0 22.5-23.5-24.0
cfm 988-1,024-1,059 883-900-935 935-971-988 794-830-847
Fan Type Propeller Propeller
Motor Output W 25 25
Running Current A 4.93-4.92-4.92 5.43-5.42-5.42 7.23-7.22-7.22 7.13-7.12-7.12
Power Consumption W 863-860-857 1,063-1,060-1,057 1,323-1,320-1,317 1,303-1,300-1,297
Power Factor % 79.6-76.0-72.6 89.0-85.0-81.3 83.2-79.5-76.0 83.1-79.4-75.9
Starting Current A 5.6 7.3
Dimensions (H×W×D) mm 560×695×265 560×695×265
Packaged Dimensions (H×W×D) mm 599×797×310 599×797×310
Weight kg 31 32
Gross Weight kg 34 36
Operation Sound dBA 45-46-47 46-47-48 46-47-48 47-48-49
Drawing No. 3D045884 3D045885
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Standard Cooling Heating Piping Length
JIS C 9612 Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB 5m