Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
E-mail: [email protected] Web: www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Products available from DANLERS
• PIR occupancy switches • Daylight linked dimmers • Manual high frequency dimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers • Heating, ventilation and air-conditioning controls • Bespoke / O.E.M. products
Please call for more information or a free catalogue.
This product conforms to BS EN 60669-2-1 and BS EN 55015.
Please ensure the most recent edition of the appropriate local wiring regulations are observed
and suitable protection is provided e.g. a 10 amp circuit breaker and voltage surge protection.
Please ensure that this device is disconnected from the supply if an insulation test is made.
This product is covered by a warranty which extends to 5 years from the date of manufacture.
Precautions and Warranty
Compact person detector, PIR switch
COPD17M
DANLERS Compact Person Detector can be mounted onto the end
of lighting battens via the 20mm knock out. The switch includes the
connection 20mm thread and can also be surface mounted onto an
external wall. It incorporates a passive infra-red quad sensor to detect
movement of a warm body within the detection zone (diagrams A& B).
The maximum detection range is up to 24m when mounted at the
maximum mounting height of 17 metres over 120 degrees.
If no more movement is detected within a pre-selected time, then
the PIR switch will turn the load off. This time lag can be set via the
TIME adjuster to 10 seconds, 20 seconds, 40 seconds, 80 seconds,
2 minutes 30 seconds, 5 minutes,10 minutes, 20 minutes or 40
minutes (diagram C).
Loading
The switch should only be connected to a 230V 50Hz AC supply.
These PIR switches can switch up to:
10 amps (2300W) of:
• Fluorescent lamps, either high frequency of switch start
• Incandescent or mains halogen lamps (recommended with
integral safety fuse)
They can also switch up to:
• 6 amps (1500W) of electronic or wire wound transformers.
• 6amps(1500W)ofcompactuorescentorLEDlampsanddrivers
(PF≥0.95).
• 1 amp (250W) of Fans.
Larger loads can be switched via a contactor.
08/05/19 INS416 COPD17M
Trouble shooting
Note: The COPD17M cannot be made to switch on / off according to
variance in ambient light levels.
The PIR does not detect
• Person is too far from the COPD17M switch, see detection diagram.
• Person is moving unusually slowly (perhaps when testing).
The PIR stops working
• Ensure the unit is mounted correctly so that no water can enter.
The PIR False triggers
• Detector is exposed to air movement on breezy days.
TIME
min max
LUX
max min
10 LUX
40m
20m
10m
5m
2.5m
80s
10s
20s
40s
1000 LUX
Installation procedure
1. Please read these notes carefully before commencing work.
Incaseofdoubtpleaseconsultaqualiedelectrician.
2.
Make sure the power is isolated from the circuit.
3. If mounting on a lighting batten, Remove the 20mm thread from the PIR
and insert it through the 20mm knockout hole with the thread facing
outwards.
4. The detector should be connected as shown in diagram D
Brown - Live in. Blue - Neutral in. White - Switched Line out.
5. Feed your cable through the thread and with the PIR facing downwards
tighten the 20mm thread to ensure a tight seal.
6. The detector can be mounted up to 17 metres high.
7. The detector can also be mounted via any of the four pre-drilled
mounting holes (see
diagram E)
.
8. Make sure the power is still isolated from the circuit.
9.
Oncethewiringhasbeencompletedandveried,switchonthesupply
and test the operation.
up to 20m
up to 24m
Strong detection zone
i.e. person moving arm
or walking towards PIR
For optimum coverage recommended
mounting height: 17m
Secondary detection
zone i.e. person walking
perpendicular to PIR
A: Ceiling mounted
detection range
For optimum coverage
recommended mounting
height 17m
C: Time adjustment
Inside detector
housing
L
load
optional manual
wall switch for
overriding off
N
230 VAC
SL
N
D: Wiring diagram
COPD17M
Time set-up
To set the TIME to a value suitable for the application, turn the PIR time to
the desired timeout (diagram C).
Whenever a person is detected, the time
lag will start again and the load will stay switched on.
10
65
37
24
60
frontside
20mm threaded
entry spout
inside
4 x mounting
holes.
3M screws
recommended
(not supplied)
17
48
Strong detection zone (up to 10m)
Recommended wall mounting
height 1 to 2.2 metres
B: Wall mounted detection range
E: Dimensions
COPD17M can also be wired in parallel

Other DANLERS Security Sensor manuals

DANLERS SILVAIR MESH-HBWD DALI User manual

DANLERS

DANLERS SILVAIR MESH-HBWD DALI User manual

DANLERS CBU-HBSP User manual

DANLERS

DANLERS CBU-HBSP User manual

DANLERS CEFPLL10VDC Quick start guide

DANLERS

DANLERS CEFPLL10VDC Quick start guide

DANLERS WM-HBSP IP66 Series User manual

DANLERS

DANLERS WM-HBSP IP66 Series User manual

DANLERS MWCEFL Quick start guide

DANLERS

DANLERS MWCEFL Quick start guide

DANLERS DBPSU Quick start guide

DANLERS

DANLERS DBPSU Quick start guide

DANLERS HBA PIR ND DSIP Quick start guide

DANLERS

DANLERS HBA PIR ND DSIP Quick start guide

DANLERS CBU-HBND IP66 User manual

DANLERS

DANLERS CBU-HBND IP66 User manual

DANLERS CBU-HBWD IP66 Series User manual

DANLERS

DANLERS CBU-HBWD IP66 Series User manual

DANLERS COPD Quick start guide

DANLERS

DANLERS COPD Quick start guide

DANLERS COPD Quick start guide

DANLERS

DANLERS COPD Quick start guide

DANLERS EasyZAPP EZ CEFL DALI Quick start guide

DANLERS

DANLERS EasyZAPP EZ CEFL DALI Quick start guide

DANLERS WM-HBWD IP66 Series User manual

DANLERS

DANLERS WM-HBWD IP66 Series User manual

DANLERS CBU-HBWD IP66 User manual

DANLERS

DANLERS CBU-HBWD IP66 User manual

DANLERS WM-HBND IP66 Series User manual

DANLERS

DANLERS WM-HBND IP66 Series User manual

Popular Security Sensor manuals by other brands

Dräger Flame 2100 Instructions for use

Dräger

Dräger Flame 2100 Instructions for use

THORLABS PDA10CF user guide

THORLABS

THORLABS PDA10CF user guide

M-E VISTUS AUDIO operating instructions

M-E

M-E VISTUS AUDIO operating instructions

Nobile R600 Mounting and operation instructions

Nobile

Nobile R600 Mounting and operation instructions

Dawson DET 161 user manual

Dawson

Dawson DET 161 user manual

Contrinex SAFETINEX instruction manual

Contrinex

Contrinex SAFETINEX instruction manual

Amprobe ULD-400 Series user manual

Amprobe

Amprobe ULD-400 Series user manual

ABB NIESSEN N9611.71 Installation Instructions and Operation

ABB

ABB NIESSEN N9611.71 Installation Instructions and Operation

Antec DECADE Elite user manual

Antec

Antec DECADE Elite user manual

Rielta ZVON-1 installation guide

Rielta

Rielta ZVON-1 installation guide

ITALIANA SENSORI ISR049 Installation, operation and maintenance manual

ITALIANA SENSORI

ITALIANA SENSORI ISR049 Installation, operation and maintenance manual

System Sensor RTS151KEYA installation instructions

System Sensor

System Sensor RTS151KEYA installation instructions

F&F DR-08 quick start guide

F&F

F&F DR-08 quick start guide

HORN LH-913C installation instructions

HORN

HORN LH-913C installation instructions

YUSHI YUT-2820 manual

YUSHI

YUSHI YUT-2820 manual

Geotechnics MiniRAE 3000 quick start guide

Geotechnics

Geotechnics MiniRAE 3000 quick start guide

NOHMI FDGJ103-D-X/XHT operating manual

NOHMI

NOHMI FDGJ103-D-X/XHT operating manual

Theben thePiccola P360-100 DE manual

Theben

Theben thePiccola P360-100 DE manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.