DANLERS COPD17M Quick start guide

Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
E-mail: [email protected] Web: www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Products available from DANLERS
• PIR occupancy switches • Daylight linked dimmers • Manual high frequency dimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers • Heating, ventilation and air-conditioning controls • Bespoke / O.E.M. products
Please call for more information or a free catalogue.
This product conforms to BS EN 60669-2-1 and BS EN 55015.
Please ensure the most recent edition of the appropriate local wiring regulations are observed
and suitable protection is provided e.g. a 10 amp circuit breaker and voltage surge protection.
Please ensure that this device is disconnected from the supply if an insulation test is made.
This product is covered by a warranty which extends to 5 years from the date of manufacture.
Precautions and Warranty
Compact person detector, PIR switch
COPD17M
DANLERS Compact Person Detector can be mounted onto the end
of lighting battens via the 20mm knock out. The switch includes the
connection 20mm thread and can also be surface mounted onto an
external wall. It incorporates a passive infra-red quad sensor to detect
movement of a warm body within the detection zone (diagrams A& B).
The maximum detection range is up to 24m when mounted at the
maximum mounting height of 17 metres over 120 degrees.
If no more movement is detected within a pre-selected time, then
the PIR switch will turn the load off. This time lag can be set via the
TIME adjuster to 10 seconds, 20 seconds, 40 seconds, 80 seconds,
2 minutes 30 seconds, 5 minutes,10 minutes, 20 minutes or 40
minutes (diagram C).
Loading
The switch should only be connected to a 230V 50Hz AC supply.
These PIR switches can switch up to:
10 amps (2300W) of:
• Fluorescent lamps, either high frequency of switch start
• Incandescent or mains halogen lamps (recommended with
integral safety fuse)
They can also switch up to:
• 6 amps (1500W) of electronic or wire wound transformers.
• 6amps(1500W)ofcompactuorescentorLEDlampsanddrivers
(PF≥0.95).
• 1 amp (250W) of Fans.
Larger loads can be switched via a contactor.
08/05/19 INS416 COPD17M
Trouble shooting
Note: The COPD17M cannot be made to switch on / off according to
variance in ambient light levels.
The PIR does not detect
• Person is too far from the COPD17M switch, see detection diagram.
• Person is moving unusually slowly (perhaps when testing).
The PIR stops working
• Ensure the unit is mounted correctly so that no water can enter.
The PIR False triggers
• Detector is exposed to air movement on breezy days.
TIME
min max
LUX
max min
10 LUX
40m
20m
10m
5m
2.5m
80s
10s
20s
40s
1000 LUX
Installation procedure
1. Please read these notes carefully before commencing work.
Incaseofdoubtpleaseconsultaqualiedelectrician.
2.
Make sure the power is isolated from the circuit.
3. If mounting on a lighting batten, Remove the 20mm thread from the PIR
and insert it through the 20mm knockout hole with the thread facing
outwards.
4. The detector should be connected as shown in diagram D
Brown - Live in. Blue - Neutral in. White - Switched Line out.
5. Feed your cable through the thread and with the PIR facing downwards
tighten the 20mm thread to ensure a tight seal.
6. The detector can be mounted up to 17 metres high.
7. The detector can also be mounted via any of the four pre-drilled
mounting holes (see
diagram E)
.
8. Make sure the power is still isolated from the circuit.
9.
Oncethewiringhasbeencompletedandveried,switchonthesupply
and test the operation.
up to 20m
up to 24m
Strong detection zone
i.e. person moving arm
or walking towards PIR
For optimum coverage recommended
mounting height: 17m
Secondary detection
zone i.e. person walking
perpendicular to PIR
A: Ceiling mounted
detection range
For optimum coverage
recommended mounting
height 17m
C: Time adjustment
Inside detector
housing
L
load
optional manual
wall switch for
overriding off
N
230 VAC
SL
N
D: Wiring diagram
COPD17M
Time set-up
To set the TIME to a value suitable for the application, turn the PIR time to
the desired timeout (diagram C).
Whenever a person is detected, the time
lag will start again and the load will stay switched on.
10
65
37
24
60
frontside
20mm threaded
entry spout
inside
4 x mounting
holes.
3M screws
recommended
(not supplied)
17
48
Strong detection zone (up to 10m)
Recommended wall mounting
height 1 to 2.2 metres
B: Wall mounted detection range
E: Dimensions
COPD17M can also be wired in parallel

Other DANLERS Security Sensor manuals

DANLERS CBU-HBWD IP66 Series User manual

DANLERS

DANLERS CBU-HBWD IP66 Series User manual

DANLERS DBPSU Quick start guide

DANLERS

DANLERS DBPSU Quick start guide

DANLERS EasyZAPP EZ CEFL DALI Quick start guide

DANLERS

DANLERS EasyZAPP EZ CEFL DALI Quick start guide

DANLERS CBU-HBSP User manual

DANLERS

DANLERS CBU-HBSP User manual

DANLERS CBU-HBND IP66 User manual

DANLERS

DANLERS CBU-HBND IP66 User manual

DANLERS CEFPLL10VDC Quick start guide

DANLERS

DANLERS CEFPLL10VDC Quick start guide

DANLERS HBA PIR ND DSIP Quick start guide

DANLERS

DANLERS HBA PIR ND DSIP Quick start guide

DANLERS CBU-HBWD IP66 User manual

DANLERS

DANLERS CBU-HBWD IP66 User manual

DANLERS COPD Quick start guide

DANLERS

DANLERS COPD Quick start guide

DANLERS WM-HBND IP66 Series User manual

DANLERS

DANLERS WM-HBND IP66 Series User manual

DANLERS WM-HBSP IP66 Series User manual

DANLERS

DANLERS WM-HBSP IP66 Series User manual

DANLERS WM-HBWD IP66 Series User manual

DANLERS

DANLERS WM-HBWD IP66 Series User manual

DANLERS SILVAIR MESH-HBWD DALI User manual

DANLERS

DANLERS SILVAIR MESH-HBWD DALI User manual

DANLERS COPD Quick start guide

DANLERS

DANLERS COPD Quick start guide

DANLERS MWCEFL Quick start guide

DANLERS

DANLERS MWCEFL Quick start guide

Popular Security Sensor manuals by other brands

olympia electronics tuv BS-360 Installation

olympia electronics

olympia electronics tuv BS-360 Installation

Hammar LifeSaver LS 101 manual

Hammar

Hammar LifeSaver LS 101 manual

Eaton CWGA-0 Series Instruction leaflet

Eaton

Eaton CWGA-0 Series Instruction leaflet

Aritech VV600 Plus installation manual

Aritech

Aritech VV600 Plus installation manual

Clas Ohlson SH98RF quick start guide

Clas Ohlson

Clas Ohlson SH98RF quick start guide

Powerfix Profi IAN 40111 Operation and safety notes

Powerfix Profi

Powerfix Profi IAN 40111 Operation and safety notes

PCB Piezotronics TORKDISC 5302D-03A Installation and operating manual

PCB Piezotronics

PCB Piezotronics TORKDISC 5302D-03A Installation and operating manual

Optex REDSCAN mini-Pro Series installation instructions

Optex

Optex REDSCAN mini-Pro Series installation instructions

Electro Detectors EDA-D5000 installation instructions

Electro Detectors

Electro Detectors EDA-D5000 installation instructions

Axis T8331-E PIR installation guide

Axis

Axis T8331-E PIR installation guide

suprema Secure I/O 2 installation guide

suprema

suprema Secure I/O 2 installation guide

DELTA DORE DTX Installation and user guide

DELTA DORE

DELTA DORE DTX Installation and user guide

Fracarro IR1000 manual

Fracarro

Fracarro IR1000 manual

STEINEL professional sensIQ manual

STEINEL

STEINEL professional sensIQ manual

Roland R1000 series E20 manual

Roland

Roland R1000 series E20 manual

Hanna 1200 user manual

Hanna

Hanna 1200 user manual

Tanda TX7110 Installation and operation manual

Tanda

Tanda TX7110 Installation and operation manual

Optex REDSCAN Series manual

Optex

Optex REDSCAN Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.