PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCT
NOTE: MESH-
HBWD DALI
is compatible with any qualified Bluetooth mesh components and commissioning tools.
We recommend Silvair Commissioning as a reliable solution.
MESH-HBWD DALI
Ceiling High Bay (Wide) Passive Infra Red (PIR)
Occupancy Detector & Photocell for DALI ballasts
Input: 100-240 Vac 50/60Hz
This MESH-HBWD DALI High Bay (Wide Detection)
Lighting Control can be mounted directly onto
solid ceilings or onto a range of different mounting
boxes. Configurable for any room occupancy style,
via the Silvair Platform (App and Web).
INSTALLATION
To be installed by a competent person with
reference to BS 7671 or equivalent local standards.
If in doubt consult a qualified electrician.
• Plan where the MESH-HBWD DALI is to be
located (see diagram 1). Switch off supply and
check for hidden cables and pipes.
• The MESH-HBWD DALI should be connected as
shown in diagrams 2 and 3:
L Live in.
N Neutral in.
+ DALI control line (polarity independant)
-
DALI control line (polarity independant)
•
Knockout or drill the approprdiate holes on the
mounting plate for attaching the plate to the ceiling
or back box (if applicable). Feed cables through
the appropriate (side or rear) entry hole. Screw the
back mounting plate to the ceiling or back box
via the mounting holes. Wire the cables into the
sensor head block terminal. Push the sensor head
onto the mounting plate and align the side clips
with the slots on the sensor heads.
OPERATION
To check the operation of the MESH-HBWD DALI:
• Turn on the supply then after 20 seconds if the
sensor has recognised movement of a person
within its zone of detection the integral red LED
on MESH-HBWD DALI will stay illuminated for 4
seconds before the red LED turns off.
• Thereafter, every time movement is detected by
MESH-HBWD DALI the integral red LED will stay
illuminated for 4 seconds.
The control also features adjustable time out (time
lag) control and daylight threshold control which
are configured by the Silvair APP.
PRECAUTIONS
• Do not place the MESH-HBWD DALI near heat
sources, fans or in ventilated ceiling voids.
• MESH-HBWD DALI can be wired in parallel
(sharing the same Live and Neutral).
• Do not place close to, or positioned such
that, any light source points directly into the
MESH-HBWD DALI.
• Ensure wires and cables are securely held within
the connection terminals.
• The MESH-HBWD DALI should be protected by
a 5 or 6 Ampere mcb or fuse.
• Disconnect the MESH-HBWD DALI from the
circuit before performing insulation testing
of the wiring circuit.
TECHNICAL DETAILS
INPUT
Voltage: 100 - 240Vac
Frequency: 50/60Hz
Max. mains current: 20mA
Standby current: 18mA
OUTPUT
Output: DALI
Output Current: 16mA
(maximum 8 ballasts)
RADIO TRANSCEIVER
Operating frequencies: 2.4... 2,483 GHz
Max. output power: +4 dBm
LUX PARAMETERS
Range: 5 - 2000 lux
OPERATING CONDITIONS
Note: The temperature difference between the
detection target and the background must be at
least 4 °C.
Ambient temperature: -20... +40 °C (lout
20mA)
Storage temperature: -25... +75 °C
Max. relative humidity: 0... 80%, non cond.
CONNECTORS
Terminal block
Wire size:
0.5mm2- 2.5mm2solid
or stranded
Wire strip length: 6-7mm
Tightening torque: 0,4 Nm/4 Kgf.cm
MECHANICAL DATA
Dimensions: 63mm x 91mm x 91mm
Weight: 105g (unpacked)
Degree of protection: IP20
Protection class: Built-in Class 2
Material (casing) Flame-retardant
polycarbonate
Finish / Colour Matt /White (RAL 9003)
Protection class: Built-in Class 2
CONFORMITY AND STANDARDS
EMC emission:
EN 301 489-1 V2.2.0, EN 301 489-17 V3.1.1,
EN 55032: 2015, EN61000-3-2: 2014,
EN61000-3-3: 2013
EMC immunity:
EN 301 489-1 V2.2.0, EN 301 489-17 V3.1.1
Environment:
Complies with WEEE and RoHS directives
Suggested typical wiring
N
L
230 Vac
5A or 6A MCB
or fuse
+
N
L
-
+
-
DALI Control Lines
DIAGRAM 2
DIAGRAM 4
plan side
63
90
90
76
DIAGRAM 1
Up to
28m diameter
Mounting height
up to 14m
Perspective view -
ceiling mounted
5 YEAR WARRANTY
MESH-HBWD DALI comes with a
5 year warranty from the date of
manufacture and is CE marked.
DIAGRAM 3
L
N
MESH-HBxx DALI
Ballast
DALI
Control Lines
Ballast
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388 E-mail: [email protected]
www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
23/08/19 INS439 MESH-HBWD DALI (Issue 01)
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCT
NOTE: MESH-
HBWD DALI
is compatible with any qualified Bluetooth mesh components and commissioning tools.
We recommend Silvair Commissioning as a reliable solution.
MESH-HBWD DALI
Ceiling High Bay (Wide) Passive Infra Red (PIR)
Occupancy Detector & Photocell for DALI ballasts
Input: 100-240 Vac 50/60Hz
STATUS LED BLINKING SEQUENCE:
MESH-HBWD DALI Unprovisioned: 30ms ON 300ms OFF
MESH-HBWD DALI Provisioned: 15ms ON 2000ms OFF
Factory Reset: 500ms ON 1000ms OFF
Factory Reset (initial burst): 100ms ON 1000ms OFF
MESH package received: 30ms ON 50ms OFF
Attention (from network): 500ms ON 500ms OFF
HALL EFFECT / FACTORY RESET:
This function allows a reset to be carried out in order to restore the default
factory settings.
Performing a factory reset restores the device to its default (factory) settings
and removes it from a Bluetooth mesh network.
A factory reset should be used as a last resort, when you cannot
communicate with the device via the app. A factory reset deletes all settings
and will require the device to be recommissioned.
TO REPROVISION:
Place a small magnet on the site of the Reset / Hall effect sensor (see
diagram 4 below). To trigger the reset the magnet must be held in position
for 5 seconds.
DIMENSIONS
DIAGRAM 3
plan side
63
90
90
76
RESET ZONE
(behind moulding). Magnet
to be placed over the Reset
Sticker for reprovisioning.
STATUS LED.
Flashes rapidly when
unprovisioned. Flashes
slowly when provisioned.
DIAGRAM 4

Other DANLERS Security Sensor manuals

DANLERS HBA PIR ND DSIP Quick start guide

DANLERS

DANLERS HBA PIR ND DSIP Quick start guide

DANLERS CBU-HBWD IP66 User manual

DANLERS

DANLERS CBU-HBWD IP66 User manual

DANLERS CEFPLL10VDC Quick start guide

DANLERS

DANLERS CEFPLL10VDC Quick start guide

DANLERS COPD17M Quick start guide

DANLERS

DANLERS COPD17M Quick start guide

DANLERS WM-HBSP IP66 Series User manual

DANLERS

DANLERS WM-HBSP IP66 Series User manual

DANLERS MWCEFL Quick start guide

DANLERS

DANLERS MWCEFL Quick start guide

DANLERS EasyZAPP EZ CEFL DALI Quick start guide

DANLERS

DANLERS EasyZAPP EZ CEFL DALI Quick start guide

DANLERS COPD Quick start guide

DANLERS

DANLERS COPD Quick start guide

DANLERS DBPSU Quick start guide

DANLERS

DANLERS DBPSU Quick start guide

DANLERS CBU-HBND IP66 User manual

DANLERS

DANLERS CBU-HBND IP66 User manual

DANLERS WM-HBWD IP66 Series User manual

DANLERS

DANLERS WM-HBWD IP66 Series User manual

DANLERS CBU-HBSP User manual

DANLERS

DANLERS CBU-HBSP User manual

DANLERS CBU-HBWD IP66 Series User manual

DANLERS

DANLERS CBU-HBWD IP66 Series User manual

DANLERS WM-HBND IP66 Series User manual

DANLERS

DANLERS WM-HBND IP66 Series User manual

DANLERS COPD Quick start guide

DANLERS

DANLERS COPD Quick start guide

Popular Security Sensor manuals by other brands

Tekmar 1773 manual

Tekmar

Tekmar 1773 manual

Menlo Systems FPD510 operating manual

Menlo Systems

Menlo Systems FPD510 operating manual

Fracarro SEL80LED quick start guide

Fracarro

Fracarro SEL80LED quick start guide

Workzone 11334 user guide

Workzone

Workzone 11334 user guide

B.E.G. LUXOMAT net PD2N-KNX-DX Mounting instructions

B.E.G.

B.E.G. LUXOMAT net PD2N-KNX-DX Mounting instructions

Interlogix GS960 Installation sheet

Interlogix

Interlogix GS960 Installation sheet

Dahua Technology ARD323-W2 user manual

Dahua Technology

Dahua Technology ARD323-W2 user manual

Viking LDB-3 product manual

Viking

Viking LDB-3 product manual

Vision ZS6301IN-5 Installation & operation manual

Vision

Vision ZS6301IN-5 Installation & operation manual

Risco BWare BUS QUAD AM G3 quick guide

Risco

Risco BWare BUS QUAD AM G3 quick guide

Infinite L-com SRCN-C267-1 user guide

Infinite

Infinite L-com SRCN-C267-1 user guide

Arch Environmental Equipment CTS 9000 IRRD Operation and installation manual

Arch Environmental Equipment

Arch Environmental Equipment CTS 9000 IRRD Operation and installation manual

ELCART TMR TL-500 instruction manual

ELCART

ELCART TMR TL-500 instruction manual

3M Faceshields user manual

3M

3M Faceshields user manual

schmersal SLC440COM Series operating instructions

schmersal

schmersal SLC440COM Series operating instructions

Siemens DELTA reflex 5TC7 2 Series Operating and mounting instructions

Siemens

Siemens DELTA reflex 5TC7 2 Series Operating and mounting instructions

GE RCR 50 - Security PrecisionLine Dual Technology Motion... installation instructions

GE

GE RCR 50 - Security PrecisionLine Dual Technology Motion... installation instructions

SFIRE SF50H user manual

SFIRE

SFIRE SF50H user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.