DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388 E-mail: [email protected]
www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
12/10/18 INS411 MESH-HBWD IP66 (XX)
WM-HBWD IP66 (XX)
IP66 Rated Ceiling High Bay (Wide) Passive
Infra Red (PIR) Occupancy Detector & Photocell
Input: 100-240 Vac 50/60Hz
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCT
NOTE: WM-HBWD IP66 is only compatible to work via the WIREPAS PLATFORM.
COLOUR OPTIONS
This product is available in 3 colour options
designated by the following product codes:
Grey: WM-HBWD IP66 GY
White: WM-HBWD IP66 WH
Black: WM-HBWD IP66 BK
5 YEAR WARRANTY
WM-HBWD IP66 comes with a 5 year
warranty from the date of manufacture
and is CE marked.
This WM-HBWD IP66 High Bay (Narrow Detection)
Lighting Control has an IP66 rated weatherproof
enclosure and can be ceiling mounted.
Configurable for any room occupancy style, via the
WIREPAS Platform (App and Web).
INSTALLATION
To be installed by a competent person with
reference to BS 7671 or equivalent local standards.
If in doubt consult a qualified electrician.
• Plan where the WM-HBWD IP66 is to be located
(see diagram 1). Switch off supply and check for
hidden cables and pipes.
• Remove the front cover by quarter turning the
four quick release fasteners to the ‘0’ position
(see diagram 4 overleaf).
• Mount the back section of the mounting box in
the required location via the 4 corner holes.
• Thread mains cable carefully through the
required membrane entry point.
• Unclip the internal back plate. Remove the
required knock out if replacing the optional
internal back plate.
• Thread mains cable into the unit. The WM-
HBWD IP66 should be connected as shown in
diagram 2:
L - Live in. N - Neutral in.
• Reclip the internal back plate if required.
• Replace the front cover ensuring the quick
release fasteners are secured in the ‘1’ position.
OPERATION
To check the operation of the WM-HBWD IP66:
• Turn on the supply then after 20 seconds if the
sensor has recognised movement of a person
within its zone of detection the integral red LED
on WM-HBWD IP66 will stay illuminated for 4
seconds before the red LED turns off.
• Thereafter, every time movement is detected by
WM-HBWD IP66 the integral red LED will stay
illuminated for 4 seconds.
The control also features adjustable time out (time
lag) control and daylight threshold control which
are configured by the WIREPAS APP.
PRECAUTIONS
• Do not place the WM-HBWD IP66 near heat
sources, fans or in ventilated ceiling voids.
• WM-HBWD IP66 can be wired in parallel
(sharing the same Live and Neutral).
• Do not place close to, or positioned such
that, any light source points directly into the
WM-HBWD IP66.
• Ensure wires and cables are securely held within
the connection terminals.
• The WM-HBWD IP66 should be protected by a
5 or 6 Ampere mcb or fuse.
• Disconnect the WM-HBWD IP66 from the
circuit before performing insulation testing
of the wiring circuit.
TECHNICAL DETAILS
INPUT
Voltage: 100 - 240Vac
Frequency: 50/60Hz
Max. mains current: 20mA
Standby current: 14mA
RADIO TRANSCEIVER
Operating frequencies: 2.4... 2,483 GHz
Max. output power: +4 dBm
LUX PARAMETERS
Range: 5 - 2000 lux
OPERATING CONDITIONS
Note: The temperature difference between the
detection target and the background must be at
least 4 °C.
Ambient temperature: -20... +40 °C (lout
20mA)
Storage temperature: -25... +75 °C
Max. relative humidity: 0... 80%, non cond.
CONNECTORS
Terminal block
Wire size:
0.5mm2- 2.5mm2
solid or stranded
Wire strip length: 6-7mm
Tightening torque: 0,4 Nm/4 Kgf.cm
MECHANICAL DATA
Dimensions: 110mm x 110mm x
73mm
Weight: 245g (unpacked)
Degree of protection: IP66
Protection class: Built-in Class 2
Material (casing)
Flame-retardant
polycarbonate/
Polypropylene.
Finish / Colour:
WM-HBWD IP66 GR
Matt /Grey
(RAL 7035)
Finish / Colour:
WM-HBWD IP66 WH
White
(RAL 9001)
Finish / Colour:
WM-HBWD IP66 BL
Black
(RAL 9005)
Protection class: Built-in Class 2
CONFORMITY AND STANDARDS
EMC emission:
EN 301 489-1 V2.2.0, EN 301 489-17 V3.1.1,
EN 55032: 2015, EN61000-3-2: 2014,
EN61000-3-3: 2013
EMC immunity:
EN 301 489-1 V2.2.0, EN 301 489-17 V3.1.1
Environment:
Complies with WEEE and RoHS directives
CB scheme:
IEC60669-1:1998, IEC60669-1:1998/AMD1:1999,
IEC60669-1:1998/AMD2:2006, IEC60669-2:2002,
IEC60669-2-1:2002/AMD1:2008,
L - Live in. N - Neutral in.
Two neutral and two live terminals
are available for easy ‘loop in’ and
‘loop out’ connection.
Suggested typical wiring
N
L
230 Vac
5A or 6A MCB
or fuse
N
L
N
L
DIAGRAM 2
DIAGRAM 3
plan side
110
110 73
DIAGRAM 1
Up to
28m diameter
Mounting height
up to 14m
Perspective view -
ceiling mounted
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388 E-mail: [email protected]
www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
12/10/18 INS411 MESH-HBWD IP66 (XX)
WM-HBWD IP66 (XX)
IP66 Rated Ceiling High Bay (Wide) Passive
Infra Red (PIR) Occupancy Detector & Photocell
Input: 100-240 Vac 50/60Hz
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCT
NOTE: WM-HBWD IP66 is only compatible to work via the WIREPAS PLATFORM.
Optional
Internal
Back Plate with
knock out options
Mounting
Box with
M20
cable entry
membrane
options.
Front Cover
and
Control Unit
IP66: Using the membrane entry -
cable: 5.2m - 17mm
Optional
Internal
Back Plate with
knock out options
Mounting
Box with
M20
cable entry
membrane
options.
Front Cover
and
Control Unit
IP66: Using the membrane entry -
cable: 5.2m - 17mm
DIAGRAM 4

This manual suits for next models

3

Other DANLERS Security Sensor manuals

DANLERS DBPSU Quick start guide

DANLERS

DANLERS DBPSU Quick start guide

DANLERS HBA PIR ND DSIP Quick start guide

DANLERS

DANLERS HBA PIR ND DSIP Quick start guide

DANLERS MWCEFL Quick start guide

DANLERS

DANLERS MWCEFL Quick start guide

DANLERS WM-HBSP IP66 Series User manual

DANLERS

DANLERS WM-HBSP IP66 Series User manual

DANLERS SILVAIR MESH-HBWD DALI User manual

DANLERS

DANLERS SILVAIR MESH-HBWD DALI User manual

DANLERS COPD Quick start guide

DANLERS

DANLERS COPD Quick start guide

DANLERS CEFPLL10VDC Quick start guide

DANLERS

DANLERS CEFPLL10VDC Quick start guide

DANLERS CBU-HBND IP66 User manual

DANLERS

DANLERS CBU-HBND IP66 User manual

DANLERS EasyZAPP EZ CEFL DALI Quick start guide

DANLERS

DANLERS EasyZAPP EZ CEFL DALI Quick start guide

DANLERS CBU-HBSP User manual

DANLERS

DANLERS CBU-HBSP User manual

DANLERS CBU-HBWD IP66 User manual

DANLERS

DANLERS CBU-HBWD IP66 User manual

DANLERS WM-HBND IP66 Series User manual

DANLERS

DANLERS WM-HBND IP66 Series User manual

DANLERS COPD Quick start guide

DANLERS

DANLERS COPD Quick start guide

DANLERS CBU-HBWD IP66 Series User manual

DANLERS

DANLERS CBU-HBWD IP66 Series User manual

DANLERS COPD17M Quick start guide

DANLERS

DANLERS COPD17M Quick start guide

Popular Security Sensor manuals by other brands

Schabus SHT 5001 Operation manual

Schabus

Schabus SHT 5001 Operation manual

THORLABS APD430 Series Operation manual

THORLABS

THORLABS APD430 Series Operation manual

Halma BEA ACTIV8 THREE ON user guide

Halma

Halma BEA ACTIV8 THREE ON user guide

Essence Smartcare Care@Home MDsense user guide

Essence Smartcare

Essence Smartcare Care@Home MDsense user guide

LINKIND LL20004 user manual

LINKIND

LINKIND LL20004 user manual

Hoyt 350 SVD quick start guide

Hoyt

Hoyt 350 SVD quick start guide

Interlogix ACL870SU-BSMF installation manual

Interlogix

Interlogix ACL870SU-BSMF installation manual

Capital Safety DBI-Sala Ultra-Lok RSQ 3504553 Specific instructions

Capital Safety

Capital Safety DBI-Sala Ultra-Lok RSQ 3504553 Specific instructions

teko Astra-5 ver.A user guide

teko

teko Astra-5 ver.A user guide

Argo WALLNER DL-07 manual

Argo

Argo WALLNER DL-07 manual

Me BELL-577 TX instruction manual

Me

Me BELL-577 TX instruction manual

C-LOGIC 640-MD instruction manual

C-LOGIC

C-LOGIC 640-MD instruction manual

Optex inSight INS-HX-80N installation instructions

Optex

Optex inSight INS-HX-80N installation instructions

ZETTLER P80SB manual

ZETTLER

ZETTLER P80SB manual

PCB Piezotronics W138A11/M038CY100AC Installation and operating manual

PCB Piezotronics

PCB Piezotronics W138A11/M038CY100AC Installation and operating manual

Siemens SBGA-34 installation instructions

Siemens

Siemens SBGA-34 installation instructions

CAME SADRIN 205 installation manual

CAME

CAME SADRIN 205 installation manual

ESYLUX PD-C360i/24 DIMplus-FM manual

ESYLUX

ESYLUX PD-C360i/24 DIMplus-FM manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.