Delta HEX050QA User manual

HEX050QA Heat Exchanger
Instruction Manual
USA
46101 Fremont Blvd, Fremont, CA 94538, U.S.A. TEL : 1-510-668-5100
FAX : 1-510-668-0680
Cabinet-Thermal-Solutions@deltaww.com
Taiwan
Delta Electronics, Inc.
252, Shang Ying Road, Kuei San District TEL : 886-(0)3-3591968
Taoyuan City 33341, Taiwan, R. O. C. FAX : 886-(0)3-3591991

Table of contents
1. Version.........................................................................................................1
2. Description...................................................................................................1
2-1. General................................................................................................1
2-2. Specification.......................................................................................1
2-3. Environmental condition...................................................................2
3. Installation ...................................................................................................2
3-1. Outline drawing..................................................................................2
3-2. Mounting panel cutout.......................................................................3
4. Electrical specification................................................................................3
4-1. Connection and LED indicator (on HEX panel)................................3
4-2. Standalone control mode...................................................................4
5. Mechanical feature......................................................................................5
5-1. Thermal path and Airflow baffle .......................................................5
5-2. Configuration.....................................................................................5
6. Maintenance and Replacement..................................................................6
6-1. Maintenance.......................................................................................6
6-2. Replacement......................................................................................7
7. MTBF and Reliability...................................................................................7
7-1. MTBF...................................................................................................7
7-2. Relibability .........................................................................................7
8. Safety............................................................................................................7
9. Accessory....................................................................................................8
9-1. Power cable........................................................................................8
9-2. Function cable...................................................................................8
10. General Safety and Warnings...................................................................8

HEX050QA Heat Exchanger Instruction Manual
Page 1
1. Version
Rev.
Description Drawn Approved Issue date
00 Issue spec. Nick Wang Adam Chen
2015/4/28
01 Standardization correction
Nick Wang Adam Chen
2016/1/25
02 Add section 10 Nick Wang Adam Chen
2016/6/10
2. Description
2-1. General
Delta Heat Exchanger (HEX) is designed for direct air to air heat
exchange to remove heat from the cabinet.
The internal and the external air circulation loops of the HEX are
separated to prevent the introduction of dust, humidity and dirt. The fan on
the external air loop conforms to IP55 protection rating.
2-2. Specification
Main feature Unit Model Number
HEX050QA
Outline Dimension (W x D x H) mm
(in) 550 x 434 x 155
(20 x 17 x 6)
Cooling Capacity (*Note 1) W/K (W/℉)
160 (89)
Rated Voltage VDC 48
Rated Current (*Note 2) A 4.0
Operating Voltage Range VDC 40 - 60
Operating Current A 1.4
Operating Power Consumption W 68
Acoustic Noise at 1.5M (SPL) dB-A 64.0 dB-A
Weight Kg (Lb) 9 (20)
* Note1 : The cooling capacity (W/K , W/°C or W/℉) is defined as Q/ (TI-TA)
Q : Heat dissipation (W) from inside of cabinet
TI : Return temperature of internal air circuit (K , °C or ℉)
TA :Ambient temperature of external air circuit (K , °C or ℉)
*Note 2 : Rated current is announcement of safety

HEX050QA Heat Exchanger Instruction Manual
Page 2
2-3. Environmental condition
Description Specification
Operating
temperature
-10°C ~ +65°C (-14°F ~ 149°F)
Storage
temperature
-40°C ~ +70°C (-40°F ~ 158°F)
Humidity External air circuit: 0 ~ 100% RH
Internal air circuit: 0 ~ 90% R
H,
Ingress protection
(on external side)l IEC60529 IP55 (NEMA 3)
GR-487 720hrs salt spray
3. Installation
3-1. Outline drawing
(1) Material : Aluminum sheet t=1.5mm
(2) Finish : Power pain , Color RAL7032
(3) Dimensional tolerance : ± 1mm [0.04”]

HEX050QA Heat Exchanger Instruction Manual
Page 3
3-2. Mounting panel cutout
:
4. Electrical specification
4-1. Connection and LED indicator (on HEX panel)
Power Connection COMM connection
User can follow dry contact definition that is Normal Open (N.O.) to
detect abnormal status from pin 1 & pin 2
Definition N. O
Connection Pin 1 & Pin 2
Control board, NTC and fan are in
normal status OPEN
NTC resistance is over range such as
“open circuit” or “short circuit” CLOSE
Fan speed is lower than 50% of
definition or fan is locked CLOSE
Dry contact max. rating : 75VDC/50mA

HEX050QA Heat Exchanger Instruction Manual
Page 4
LED indicator
INNER FAN / OUTER FAN / STATUS LEDs indicate fan and NTC
sensor status .
Depress "TEST" button to start auto-test of outer and inner fans
running from low to high speed. Turn off by depressing the “TEST” button
again .
INNER FAN OUTER FAN STATUS
Normal GREEN GREEN GREEN
Failed* RED RED RED
Normal
(touch TEST / CLEAN) Blinking
GREEN Blinking
GREEN N/A
Failed*
(touch TEST / CLEAN) Blinking
RED Blanking
RED N/A
* FAN failed : Fan speed is lower than 50% of definition or fan is locked
* STATUS Failed : NTC resistance is over range such as “open circuit” or
“short circuit”
4-2. Standalone control mode
HEX can detect ambient temperature to control cooling capacity ,
both internal fan and external fan speed default setting are shown as below
Cooling capacity (W/K) vs. Temperature

HEX050QA Heat Exchanger Instruction Manual
Page 5
Inner fan speed vs. Temperature Outer fan speed vs. Temperature
5. Mechanical feature
5-1. Thermal path and Airflow baffle
With forced convection using the axial fan ,
warm air generated by the equipment will be
blown into the internal return opening and pass
though the HEX, then flow out from internal
supply opening. The air supply of the cold air
will be used to cool down the system .
On the opposite side, cooler air from the
surrounding environment will be drawn in from
the external air inlet side , and push the heat of
the HEX out from the external air exhaust side.
The thermal exchange path is shown in right .
5-2. Configuration
Item
Q'ty
Description
1 1 Chassis assy
2 1 Heat exchange CORE
3 1 Controller
4 1 Internal fan plate assy
5 1 External fan plate assy

HEX050QA Heat Exchanger Instruction Manual
Page 6
6. Maintenance and Replacement
Be sure to SHUT DOWN the power before proceeding with any
maintenance or component replacement .
6-1. Maintenance
Monthly
Use brush and low pressure air to blow out the dust or any debris
on both internal/external air inlet and air outlet opening .
Quarterly
Follow below maintenance sequence
Internal loop maintenance :
* The maintenance is from internal side .
* Use screw driver to remove secured screw to disassemble
the internal fan plate assy (Item 4) from bottom of chassis assy
(item 1) , and disconnect internal fan from controller
(Item ) , Note the connection location .
* Use brush and low pressure air to remove dust on internal fan
plate assy (Item 4) , internal fan & heat exchange core air
intake opening at internal side .
* Connect fan to controller (Item 3) and re-attach internal plate
assy (Item 4) with chassis assy (Item 1) .
External loop maintenance :
* Due to the maintenance have to damage the waterproof
foam on the bottom of HEX , Delta propose to return to
factory for maintenance or request Delta authorized support
for assistance if customer find external airflow loop has
obstruction to drop cooling capacity .
Test Power on and depreess “TEST” button on panel to proceed with
auto test . Follow LED status to check that HEX has resumed to normal
function after maintenance .

HEX050QA Heat Exchanger Instruction Manual
Page 7
6-2. Replacement
Delta HEX is designed with dry contact alarm output and LED
indicator on panel shown below to describe abnormal situation .
Refer to Section 4-1 for checking abnormal part is internal fan ,
external fan or controller for abnormalities .
In cases of parts abnormality , Delta will follow the reading and submit
spare part(s) below for replacement .
Internal fan P/N : AFB1548EH-BJ51
External fan P/N : AFB1548VH-DH2L
Controller P/N : HEX050QA-000C
User can then refer to maintaince sequence on previous page , or
request Delta authorized support for assistance .
7. MTBF and Reliability
7-1. MTBF
L10 Fan life is expected to be a minimum 80,000 hours continuous
operation at 40°C with 15 ~ 65%RH .@ label rated voltage
7-2. Relibability
Test item Condition
High temperature IEC 60068-2-2
Low temperature IEC 60068-2-1
High temp. / High humidity IEC 60068-2-14 TEST Nb
Temperature cycle IEC 60068-2-3
Vibration ETSI 300 019-1-4 CLASS 4.1
Ingress protection
(External side)
IEC 60529 IP55 (NEMA 3)
GR-487 720hrs salt spray
Package bump IEC 60068-2-29
8. Safety

HEX050QA Heat Exchanger Instruction Manual
Page 8
9. Accessory
9-1. Power cable
9-2. Function cable
10. General Safety and Warnings
* Some electronic parts have a high operating temperature .
Use caution at all times.
* Incorrect installation may cause damage and/or injury.
* Installation and maintenance should be performed only by qualified
personnel . Use caution at all times.
* Ensure the grounding wire is connected before powering on the system.
* Ensure the cover and the mounting hardware are secure upon installation.
* All the cables connected to the unit must confirm to UL standards.
Table of contents
Other Delta Industrial Equipment manuals

Delta
Delta HEX200PB User manual

Delta
Delta HEX100PC Series User manual

Delta
Delta HEX080QA Series User manual

Delta
Delta 46-461 User manual

Delta
Delta DVP-ES2 User manual

Delta
Delta DVP-ES3 Series User manual

Delta
Delta HEX150PB Series User manual

Delta
Delta DVP02LC-SL User manual

Delta
Delta HEX110QA User manual

Delta
Delta HEX260PA-A User manual

Delta
Delta TP02G-AS1 User manual

Delta
Delta HEX020VA User manual

Delta
Delta HEX070PB User manual

Delta
Delta WHITEWATER DF Series User manual

Delta
Delta DTM Series User manual

Delta
Delta HEX080PD Series User manual

Delta
Delta 32-325 User manual

Delta
Delta PMC-24V300W1B Series User manual

Delta
Delta ASRTU-EC16AP1TA User manual

Delta
Delta TP02G-AS1 User manual