Installation Instructions
Dimplex Ultra-Slim Storage Heaters
Models XL12N, XL18N, XL24N
Twin Sensor Models XLS12N Automatic,
XLS18N Automatic, XLS24N Automatic
(96513 Iss. 12)
IMPORTANT
These instructions should be read carefully and retained for future reference.
Note also the information given on the appliance.
This heater is VERY HEAVY. In order to maintain
stability and to ensure its future safety in use, it is
essential that the heater is FIXED SOUNDLY TOAWALL
and that the feet are mounted on a FIRM, LEVEL
SURFACE. Care should be taken to avoid irregular
surfaces, such as may result from tiled surrounds
partially protruding under the heater. It is important
that the following instructions are strictly followed.
IT IS IMPORTANTTHAT THE FIXING DEVICE CHOSEN
ISAPPROPRIATETOTHEWALLMATERIALTOWHICH
THE HEATER IS BEING FIXED. SOME MODERN
INTERNALBUILDINGMATERIALSAREVERYLOW
DENSITY BLOCK AND REQUIRE SPECIALISED FIXING
DEVICES TO PROVIDEASAFE, SECURE
INSTALLATION.
The installation of this appliance should be carried out by
competentpersonnelandbeinaccordancewith the current
IEE wiring regulations. For the assembly of the heater tools
requiredareaNo.2pozidriver,anelectricalscrewdriverwitha
4mmwideblade anda 8mmAF openended or boxspanner.
Asmall mirror will aid insertion of the front panel retaining
screws.
OnlyHeatResistingCable(min.ratingT85)shouldbeused.
DONOTCOVEROROBSTRUCTthesurfacesofthe
appliance.
DONOTPOSITIONunderwindowswherecurtainsmay
contactthe heater. (Seeminimum clearances, stage6).
DONOTPLACE OBJECTSincontactwiththeheater.
If, during any reassembly of the heater, a part of the thermal
insulationshowsdamageordeteriorationwhichmayimpair
safety, it should be replaced with an identical part.
Connection to a 30 amp Ring Circuit
XLN/XLSN STORAGE HEATERS SHOULD NOT BE CONNECTED TO A 30 AMP RING CIRCUIT.
XL/XLS24N STORAGE HEATERS SHOULD NOT BE CONNECTED TO A FUSED SPUR.
Bricks are in packs of two.
The pack catalogue number is XT 8300
XL12/XLS12N - 12kWh
8 Bricks (4 Packs) XL18/XLS18N - 18kWh
12 Bricks (6 Packs) XL24/XLS24N - 24kWh
16 Bricks (8 Packs)
ThisappliancecomplieswiththeEuropeanStandardsEN60335-1,EN60335-2-61,EN61000-3-2,EN61000-3-3,EN55014andEN55104forSafety&ElectromagneticCompatibility.
ThesestandardscovertherequirementoftheEMCDirectives89/336&73/23