3 / 4
EN Installation and configuration instructions
VistaScan Perio Plus
Only fully-qualified personnel may set-up, install or operate this appli-
ance.
Minimum requirements
Imaging program DBSWIN or VistaEasy by Dürr Dental
Third-party software on request
Computer system See "System requirements for computer systems for
imaging“ (9000-618-148/01)
1 Connecting up the device
The device can be connected to the USB or network.
The connecting cables are contained in the scope of delivery.
Do not connect the device to the USB and to the network at the
same time.
• Connect the connecting cable (USB/network) to the device.
• If necessary, connect the network cable with the network.
Only connect the USB connecting cable to the computer when the
installation assistant asks you to do so.
• Switch the device on.
2 Installation
2.1 Driver installation (only for USB connection)
• Close all programs.
• Place the provided DBSWIN DVD (from Version 5.3) into the DVD drive.
The start window opens.
• If the DVD does not start automatically, execute the file "CD_Start.exe".
• Select the required language.
• Go to the "Driver" tab.
• Click "Duerr Dental Driver Installation".
• Confirm the message by clicking "OK".
The "Dürr Dental Driver Setup" installation assistant starts.
• Follow the instructions of the installation assistant.
2.2 Setting up the network (only for network connection)
• Switch on the network devices (router, PC, and switch).
• Check that TCP port 2006 and UDP port 514 are released in the firewall
being used; if not, release them.
If you are using the Windows firewall, you do not need to check the ports
since you are asked if you want to release them during the driver installa-
tion process.
3 Configuration
For both connection types (USB and network), the configuration takes place
using VistaNetConfig, which is automatically installed during the installation
of DBSWIN or VistaEasy.
• Click Start>AllPrograms>DürrDental>VistaCong>VistaNetCong.
• Click the "Refresh" symbol .
• Activate the connected device in the "Registered" column.
You can also register multiple devices.
3.1 Configuring the device with a USB connection
You can change the device name and query the configuration in the "Vista-
Net device configuration" window.
• Click the "Edit" button .
• If necessary, change the name.
• Click "Apply" to save the configuration.
4 / 4
3.2 Configuring the device with a network connection
You can change the device name, manually enter an IP address, and query
information in the "VistaNet device configuration" window.
• Click the "Edit" button .
Entering a permanent IP address (recommended)
• Deactivate DHCP.
• Enter an IP address, subnet mask, and gateway.
• Click "Apply" to save the configuration.
To restore the device to the factory settings, hold down the reset
button on the device for 15 to 20 seconds whilst switching the
device on.
4 Testing the device
You can read in an X-ray image to test whether or not the device is con-
nected up properly.
• Go to the "Test" tab.
• Select the device from the "Registered Devices" selection list.
• Select the mode class.
• Select the mode.
• Click "Read image".
• Read in the image plate.
To scan image data, refer to the VistaScan Perio Plus installation
and operating instructions (order number 9000-618-167/..).
5 Check amount of light exposure
The oscilloscope can be used to measure the amount of light exposure to
the unit.
• Choose the „Oscilloscope“ option.
• Select the device from the "Registered Devices" selection list.
• Slide the regulator bar for the HV value to 650.
• Click „Start/Stop“ to begin measurements.
• Click „Start/Stop“ to end measurements.
• Pull the left hand slider bar downwards until all three lines can clearly be
seen.
Blue line: Measured light exposure
Red line: Maximum value
Green line: Average value
The test has been passed successfully when the measured value does
not exceed 450.
• When the maximum value is higher than 450, reduce the amount of room
lighting.
6 Electrical safety check
• Carry out the electrical safety check in accordance with national and local
regulations.
• Document the results.
DÜRR DENTAL SE
Höpfigheimer Str.17
74321 Bietigheim-Bissingen, Germany 2011/09/01
9000-618-168/01


Other manuals for VistaScan Perio Plus

1

Other Durr Dental Dental Equipment manuals

Durr Dental VistaScan Combi View Programming manual

Durr Dental

Durr Dental VistaScan Combi View Programming manual

Durr Dental Vector User manual

Durr Dental

Durr Dental Vector User manual

Durr Dental VistaScan Perio Plus User manual

Durr Dental

Durr Dental VistaScan Perio Plus User manual

Durr Dental Quattro P 20 User manual

Durr Dental

Durr Dental Quattro P 20 User manual

Durr Dental VistaScan Mini View User manual

Durr Dental

Durr Dental VistaScan Mini View User manual

Durr Dental Variosuc 0624 User manual

Durr Dental

Durr Dental Variosuc 0624 User manual

Durr Dental VistaCam iX User manual

Durr Dental

Durr Dental VistaCam iX User manual

Durr Dental VistaScan Perio Net Quick guide

Durr Dental

Durr Dental VistaScan Perio Net Quick guide

Durr Dental VistaVox S User manual

Durr Dental

Durr Dental VistaVox S User manual

Durr Dental Duo Tandem User manual

Durr Dental

Durr Dental Duo Tandem User manual

Durr Dental VistaCam iX Manual

Durr Dental

Durr Dental VistaCam iX Manual

Durr Dental Vector Paro User manual

Durr Dental

Durr Dental Vector Paro User manual

Durr Dental Tornado 4 User manual

Durr Dental

Durr Dental Tornado 4 User manual

Durr Dental Periomat Plus User manual

Durr Dental

Durr Dental Periomat Plus User manual

Durr Dental Hygowater User manual

Durr Dental

Durr Dental Hygowater User manual

Durr Dental Vector Scaler User manual

Durr Dental

Durr Dental Vector Scaler User manual

Durr Dental VistaScan Nano Easy User manual

Durr Dental

Durr Dental VistaScan Nano Easy User manual

Durr Dental PTS 120 User manual

Durr Dental

Durr Dental PTS 120 User manual

Durr Dental Tyscor VS 1 Plus User manual

Durr Dental

Durr Dental Tyscor VS 1 Plus User manual

Durr Dental VistaScan Nano Easy User manual

Durr Dental

Durr Dental VistaScan Nano Easy User manual

Durr Dental VistaScan Mini Easy 2.0 User manual

Durr Dental

Durr Dental VistaScan Mini Easy 2.0 User manual

Durr Dental CA 4 User manual

Durr Dental

Durr Dental CA 4 User manual

Durr Dental VistaScan Net User manual

Durr Dental

Durr Dental VistaScan Net User manual

Durr Dental V 600 User manual

Durr Dental

Durr Dental V 600 User manual

Popular Dental Equipment manuals by other brands

KaVo MASTERmatic LUX M07 L Instructions for use

KaVo

KaVo MASTERmatic LUX M07 L Instructions for use

Blancone Arcus Operation guide

Blancone

Blancone Arcus Operation guide

Henry Schein Capsule Mixer Cap II Instructions for use

Henry Schein

Henry Schein Capsule Mixer Cap II Instructions for use

Dentsply Sirona Primescan Connect operating instructions

Dentsply Sirona

Dentsply Sirona Primescan Connect operating instructions

Dentsply Sirona Spacefile Directions for use

Dentsply Sirona

Dentsply Sirona Spacefile Directions for use

Fona MyCrown Mill Service manual

Fona

Fona MyCrown Mill Service manual

Reborn Endo R-SMART PLUS user manual

Reborn Endo

Reborn Endo R-SMART PLUS user manual

Medidenta MEDITORQUE ELITE ME-KIT Instructions for use

Medidenta

Medidenta MEDITORQUE ELITE ME-KIT Instructions for use

EMS AirFlow Master Piezon Operation instructions

EMS

EMS AirFlow Master Piezon Operation instructions

DENTAURUM desktop Compact Instructions for use

DENTAURUM

DENTAURUM desktop Compact Instructions for use

KaVo INTRAcompact 2967 CHC Instructions for use

KaVo

KaVo INTRAcompact 2967 CHC Instructions for use

KaVo SCAN EXAM user manual

KaVo

KaVo SCAN EXAM user manual

Wassermann HSS-99 Replacement manual

Wassermann

Wassermann HSS-99 Replacement manual

KaVo PROTAR evo Document

KaVo

KaVo PROTAR evo Document

3D Systems NextDent 5100 Setup

3D Systems

3D Systems NextDent 5100 Setup

Coltene DIATECH Z-Rex Diamond Instructions for use

Coltene

Coltene DIATECH Z-Rex Diamond Instructions for use

NSK PANA-MAX QD Operation manual

NSK

NSK PANA-MAX QD Operation manual

KaVo MASTERtorque LUX M9000 L COLOR 1.007.9900 Instructions for use

KaVo

KaVo MASTERtorque LUX M9000 L COLOR 1.007.9900 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.