E2S D2xB1XH1 User manual

European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D211-00-251-IS
Issue 1
20-08-22
Sheet 1 of 6
INSTRUCTION MANUAL
D2xB1XH1 & D2xB1XH2 Xenon Beacons
For use in Hazardous Locations
D2XB1XH1
D2XB1XH2
1) Product Table
2) Warnings
DO NOT OPEN WHEN AN EXPLOSIVE
ATMOSPHERE IS PRESENT
DO NOT OPEN WHEN ENERGISED
POTENTIAL ELECTROSTATIC CHARGING
HAZARD - CLEAN ONLY WITH A DAMP
CLOTH
HIGH VOLTAGE SHOCK HAZARD. WAIT 5
MINUTES AFTER REMOVING POWER
BEFORE OPENING THE ENCLOSURE
Avertissement:
NE PAS OUVRIR UN PRESENCE
D’ATMOSPHERE EXPLOSIVE
NE PAS OUVRIR ENERGIE
DANGER POTENTIEL CHARGE
ÉLECTROSTATIQUE - NETTOYER
UNIQUEMENT AVEC UN CHIFFON HUMIDE
HAUT TENSION, RISK DE CHOC.
ATTENDEZ 5 MINUTES APRES AVOIR
DEBRANCHE L’ALIMENTATION AVANT
D’OUVRIR LA BOITIER
3) Rating & Marking Information
3.1. Public Mode Fire Alarm Ratings
The D2xB1XH1 and D2xB1XH2 are certified for use as public
mode visual alarm devices in accordance with UL1971 Third
Edition and UL1638 Fifth Edition / CAN/ULC-S526 Fourth
Edition.
See fire instruction manual D211-00-251-IS-SC-UL.
Model Nom. Voltage Voltage Range Max Operating
Current*
D2xB1XH1 24Vdc 20-28Vdc 296mA
D2xB1XH2 48Vdc 48Vdc 609mA
*max. rms current at worst-case voltage in voltage range
For detailed max current ratings of the device please see Section 13.
Table 1: Electrical Ratings.

European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D211-00-251-IS
Issue 1
20-08-22
Sheet 2 of 6
3.2. ATEX / IECEx / UKEx Ratings
Standards
EN IEC 60079-0:2018 / IEC60079-0:2017 (Ed 7):
Explosive Atmospheres - Equipment. General Requirements
EN IEC 60079-7:2015 +A1:2018 / IEC 60079-7:2018 (Ed. 5.1):
Explosive Atmospheres - Equipment Protection by Increased
Safety "e"
EN 60079-31:2014 / IEC 60079-31:2013 (Ed 2):
Explosive Atmospheres - Equipment Dust Ignition Protection
by Enclosure "t"
Ratings
D2xB1XH1 :
Ex ec IIC T2 Gc Ta -40°C to +50°C
Ex tc IIIC T80°C Dc Ta -40°C to +50°C
D2xB1XH2:
Ex ec IIC T1 Gc Ta -40°C to +50°C
Ex tc IIIC T105°C Dc Ta -40°C to +50°C
Certificate No. DEMKO 14 ATEX 4786493904X
IECEx ULD 14.0004X
UL21UKEX2131X
ATEX Mark, Equipment
Group and Category:
II 3G
II 3D
CE Marking
UKCA Marking
3.3. NEC & CEC Ratings
NEC & CEC Class / Division Ratings for US / Canada
Standards
UL 121201-2021 (Ed. 9)
CAN/CSA C22.2 No. 213-17 (Ed. 3)
Ratings
D2xB1XH1: Class I Div 2 ABCD T2D Ta -40°C to +50°C
Class I Div 2 ABCD T3 Ta -40°C to +45°C
Class II Div 2 FG T6 Ta -40°C to +50°C
Class III Div 1&2 Ta -40°C to +50°C
D2xB1XH2:
Class I Div 2 ABCD T1 Ta -40°C to +50°C
Class I Div 2 ABCD T2 Ta -40°C to +45°C
Class II Div 2 FG T4A Ta -40°C to +50°C
Class II Div 2 FG T5 Ta -40°C to +45°C
Class III Div 1&2 Ta -40°C to +50°C
Installation must be carried out in compliance with the National
Electric Code / Canadian Electric Code
NEC Class / Zone ratings US
Standards
UL 60079-0 (Ed. 7):
Explosive Atmospheres - part 0: Equipment - General
Requirements
UL 60079-7 (Ed. 5):
Explosive Atmospheres - Equipment Protection by Increased
Safety "e"
UL 60079-31 (Ed. 2)
Explosive Atmospheres - Equipment Dust Ignition Protection
by Enclosure "t"
Ratings
D2xB1XH1:
Class I Zone 2 AEx ec IIC T2 Gc Ta -40°C to
+50°C
Zone 22 AEx tc IIIC T80°C Dc Ta -40°C to +50°C
D2xB1XH2:
Class I Zone 2 AEx ec IIC T1 Gc Ta -40°C to
+50°C
Zone 22 AEx tc IIIC T105°C Dc Ta -40°C to +50°C
Installation must be carried out in compliance with the National
Electric Code.
CEC Class / Zone ratings Canada
Standards
CAN/CSA C22.2 No. 60079-0 (Ed. 4) 02/2019
Explosive Atmospheres - Part 0: Equipment - General
Requirements
CAN/CSA C22.2 No. 60079-7 (Ed. 2)
Explosive Atmospheres - Equipment Protection by Increased
Safety "e"
CAN/CSA C22.2 No. 60079-31 (Ed. 2)
Explosive Atmospheres - Equipment Dust Ignition Protection
by Enclosure "t"
Rating
D2xB1:
X05DC024
Ex ec IIC T2 Gc X Ta -40°C to +50°C
Ex tc IIIC T80°C Dc Ta -40°C to +50°C
D2xB1:
X10DC024
Ex ec IIC T1 Gc X Ta -40°C to +50°C
Ex tc IIIC T105°C Dc Ta -40°C to +50°C
Installation must be carried out in compliance with the Canadian
Electric Code
4) Zones, Gas Group, Category and
Temperature Classification
When connected to an approved system the D2xB1XH1 and
D2xB1XH2 xenon beacons may be installed in:
Area Classification
Zone 2
Explosive gas air mixture not likely to occur in
normal operation, and if it does, it will only
exist for a short time.
Zone 22
Explosive dust air mixture not likely to occur in
normal operation, and if it does, it will only
exist for a short time.
Gas Groupings
Group IIA Propane
Group IIB Ethylene

European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D211-00-251-IS
Issue 1
20-08-22
Sheet 3 of 6
Group IIC Hydrogen and Acetylene
Temperature Classification for Gas Applications
T1 450ºC
T2 300ºC
T3 200ºC
(D2xB1XH1 only)
Dust Groupings
(ATEX / IECEx
/ UKEX
only)
Group IIIA Combustible Flyings
Group IIIB Non-conductive Dust
Group IIIC Conductive Dust
Maximum Surface Temperature for Dust Applications
(ATEX / IECEx
/ UKEX
only)
D2XB1XH1: 80°C
D2XB1XH2: 105°C
Equipment Category
3G / 3D
Equipment Level Protection
Gc, Dc
Ambient Temperature Range
-40°C to +70°C
IP Rating
IP6X to EN/IEC60079
-
0
IP66 to EN60529
To maintain the ingress protection rating, the two off cable entries
must be fitted with suitably rated, certified cable entry and/or
blanking devices during installation.
Type Rating
Per UL50E /
NEMA250: 4 / 4X / 3R / 13
Installation must be carried out in compliance with the latest
issue of the following standards:
EN60079-14 / IEC60079-14: Explosive atmospheres -
Electrical installations design, selection and erection
EN60079-10-1 / IEC60079-10-1: Explosive atmospheres -
Classification of areas. Explosive gas atmospheres
EN60079-10-2 / IEC60079-10-2: Explosive atmospheres –
Classification of areas. Explosive dust atmospheres
For detailed max and surge current ratings of the device
please see Section 14.
5) Special Conditions of Use
Special Condition for safe Use as stated on the Type
Examination Certificate DEMKO 14 ATEX 4786493904X /
CoC IECEx ULD 14.0004X:
When used for a Group III application, the surface of the
enclosure may store electrostatic charge and become a
source of ignition in applications with a low relative humidity
<~30% relative humidity where the surface is relatively free of
surface contamination such as dirt, dust, or oil.
Guidance on protection against the risk of ignition due to
electrostatic discharge can be found in EN TR50404 and IEC
TR60079-32.
End user shall adhere to the manufacturer’s installation and
instruction when performing housekeeping to avoid the
potential for hazardous electrostatic charges during cleaning,
by using a damp cloth.
To maintain the ingress protection rating and mode of
protection, the cable entries must be fitted with suitably rated,
certified cable entry and/or blanking devices during
installation.
6) Product Mounting and Access
6.1. Location and Mounting
The location of the beacon should be made with due regard
to the area over which the warning signal must be visible. It
should only be fixed to services that can carry the weight of
the unit.
The D2x beacon should be secured to any flat surface using
the two 7mm fixing holes in the feet of the base. The 2-off
mounting feet supplied with the unit must first be fitted to the
base using the 2-off M4 X 12mm countersunk screws
provided. Additional feet are available as spare parts if
required. The unit can also be pole mounted using the ¾”
NPT Entry in the centre of the base. See Fig. 1.
Fig. 1 Fixing Location for Public Mode
6.2. Access to the Enclosure
Warning – High voltage may be
present, risk of electric shock.
DO NOT open when energised,
disconnect power before opening.
Warning – Hot surfaces. External
surfaces and internal components
may be hot after operation, take
care when handling the equipment.
To access the enclosure, loosen the four M4 posi pan head
screws and withdraw the cover.
Fig. 2 Accessing the Enclosure.
To replace cover, check that the ‘O’ ring seal is in place.
Carefully push the cover in place. Insert M4 screws with fiber
washers and tighten to 3Nm torque.
M4 Cover
Screw (4-off)
(Appropriate cable
entry devices to be
customer supplied)
Cover
116,0mm [4,52in.]
116,0mm [4,52in.]
168,0mm [6,55in.]
130,1mm [5,07in.]
132,4mm [5,17in.]
Ø6,92mm [Ø0,270in.] 3/4" NPT
(For pole mount)
M4 X 12mm
Countersunk screw,
customer to fix

European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D211-00-251-IS
Issue 1
20-08-22
Sheet 4 of 6
E
E
+
+
-
-
7) Selection of Cable, Cable Glands, Blanking
Elements & Adapters
When selecting the cable size, consideration must be given
to the input current that each unit draws (see section 14), the
number of beacons on the line and the length of the cable
runs. The cable size selected must have the necessary
capacity to provide the input current to all of the sounders
connected to the line.
When selecting the cable size consideration must be given to
the voltage drop over the length of the cable run to ensure
the min. input voltage at the point of use (voltage range, see
section 14)
The voltage drop depends on:
- The total current draw of the devices installed on
this cable run
- The wire size and total length of the cable run,
determining the total resistance of this cable run
- The minimum output voltage supplied by the power
supply
The voltage drop and input voltage at the point of use can be
calculated as follows:
Total Wire resistance =
Wire resistance / 1000ft x length of cable run x 2
(length of cable run needs to be multiplied by two to account
for two wires going to and from the unit)
Total current draw =
Current draw per unit x number of units
Voltage Drop = Total current draw x Total wire resistance
Minimum output of power supply =
Min. voltage at point of use + voltage drop
The entries are 2-off M20 x 1.5 thread, 2-off ½” NPT thread &
1-off ¾” NPT thread
For ambient temperatures over +45ºC the cable entry
temperature may exceed +70ºC. Therefore suitable heat
resisting cables and cable glands, rated to min. 85°C must be
used.
If a high IP (Ingress Protection) rating is required then a
suitable sealing washer must be fitted under the cable glands
or blanking plugs.
For use in explosive dust atmospheres, a minimum ingress
protection rating of IP6X must be maintained.
For use in explosive gas atmospheres, a minimum ingress
protection rating of IP54 must be maintained.
NPT plugs should be greased before insertion.
8) Cable Connections
Electrical connections are to be made into the terminal blocks
on the PCBA located in the enclosure. See section 5 of this
manual for access to the enclosure.
Wires having a cross sectional area between 0.5 mm² to
2.5mm² can be connected to each terminal way. If an input
and output wire is required the 2-off Live/Neutral or +/-
terminals can be used. If fitting 2-off wires to one terminal
way the sum of the 2-off wires must be a maximum cross
sectional area of 2.5mm². Strip wires to 8mm. Wires may also
be fitted using ferrules. Terminal screws need to be tightened
down with a tightening torque of 0.56 Nm / 5 Lb-in. When
connecting wires to the terminals great care should be taken
to dress the wires so that when the cover is inserted into the
chamber the wires do not exert excess pressure on the
terminal blocks. This is particularly important when using
cables with large cross sectional areas such as 2.5mm².
9) Wiring
For further wiring schematics refer to document D211-06-251
9.1. Terminals
3-off 2-way terminal blocks are provided on the beacons for
power. There are 2-off +ve, 2-off –ve, 2-off Earth.
Fig. 3 D2XB1H1 & D2xB1H2 Terminals
9.2. Line Monitoring
On D2xB1XH1 & D2xB1XH2 DC units, DC reverse line
monitoring can be used if required. All DC beacons have a
blocking diode fitted in their supply input lines. An end of line
monitoring resistor can be connected across the +ve and –ve
terminals. If an end of line resistor is used it must have the
following values:
Min. Resistance Min. Power
3.9KΩ 0.5W
1KΩ 2W
The resistor must be connected directly across the +ve and
-ve terminals as shown in the following drawing. Form the
resistor legs as shown in Fig. 7a, remove the +ve and –ve
terminal plugs and fit the resistor across the two terminal
plugs before refitting them to the PCBA as shown in Fig. 7b.
A spacing of at least 1/16” (1.58mm) must be provided
through air and over surfaces between uninsulated live parts.

European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D211-00-251-IS
Issue 1
20-08-22
Sheet 5 of 6
+
+
-
-
Fig. 4 End of Line Resistor Forming
Fig. 5 End of Line Resistor Placement
10) Earthing
The unit has both internal and external earth terminals,
(please see fig 3).
Internal earthing connections should be made to the internal
earth terminal on the PCBA. The earth conductor should be
at least equal in size and rating to the incoming power
conductors. The internal earth bonding wire connects the
PCBA earth terminal to the internal earth terminal in the
enclosure back box.
External earth connections should be made to the M5 earth
stud, using a ring crimp terminal to secure the earth
conductor to the earth stud. The external earth conductor
should be at least 4mm2 in size. The external earth crimp
ring should be located between the two M5 plain washers
provided and securely locked down with the M5 spring
washer and M5 nut.
11) DIP Switch
Please note that the D2xB1XH1 & D2xB1XH2 beacons have
a DIP Switch that is NOT customer configurable. This should
only ever be set to ‘00’.
Fig. 6 DIP Switch setting ‘00’
12) Maintenance, Overhaul & Repair
Maintenance, repair and overhaul of the equipment should
only be carried out by suitably qualified personnel in
accordance with the current relevant standards:
EN60079-19
IEC60079-19
Explosive atmospheres - Equipment repair,
overhaul and reclamation
EN 60079-17
IEC60079-17
Explosive atmospheres - Electrical
installations inspection and maintenance
To avoid a possible ELECTROSTACTIC CHARGE the unit
must only be cleaned with a damp cloth.
Units must not be opened while an explosive atmosphere is
present.
If opening the unit during maintenance operations a clean
environment must be maintained and any dust layer removed
prior to opening the unit.
End of Line Resistor

European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D211-00-251-IS
Issue 1
20-08-22
Sheet 6 of 6
13) Electrical Ratings
13.1 Operating current Consumption
Table 6 – Electrical Ratings
Model Nom.
Voltage
Voltage Range Flash Rate Setting Max. operating current
##
D2xB1XH1DC024 24Vdc 20-28Vdc 1Hz (60fpm) 0.296A
D2xB1XH2DC024 24Vdc 20-28Vdc 1Hz (60fpm) 0.609A
For Public Mode Fire Alarm use
## max. rms current at worst-case voltage in voltage range.

_______________________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880
Document No. D211-00-251-IS-SC-UL Issue A 22-07-2022 Sheet 1 of 4
FIRE
INSTRUCTION MANUAL
D2xB1XH1 & D2xB1XH2 Xenon Beacons
For use in Hazardous Locations
1) Public Mode Fire Alarm Ratings
The D2xB1XH1 and D2xB1XH2 are certified for use as public mode visual alarm devices in accordance with UL1971 Third Edition
and UL1638 Fifth Edition / CAN/ULC-S526 Fourth Edition.
For use in public-mode fire alarm systems the beacon must be installed without the wire guard or plastic lens cover.
For light output ratings see section 2.
Testing of synchronization requirements of UL1971 & UL1638 / CAN/ULC-S526 were conducted by UL using a total of 6 units
connected to the same wire run. Auto-synchronization does not require the use of any external sync modules or protocols. Providing
the correct cable has been selected an unlimited number of units will remain synchronized when powered from the same source.
2) Light output for Fire alarm use
In order to meet the requirements for UL 1971, (when used with 1Hz Flash rate), the installation must be carried out to the correct
NFPA standards and guidelines.
2.1 Horizontal Light Output Dispersion for wall mounting – public mode
0° 15°15° 30°
45°
60°
75°
90°
90°
30°
45°
60°
75°
Fig. 1 – Horizontal dispersion angles for wall mounting
Table
1
A
-
D2xB1XH1
-
Horizontal Light Output Dispersion for Wall Mounting
Viewing Angle
% Of Rating
Intensity (cd) at 1Hz flash rate
0
⁰
100
18.18
5-25
⁰
90
16.36
30-45
⁰
75
13.64
50
⁰
55
10.00
55
⁰
45
8.18
60
⁰
40
7.27
65
⁰
35
6.36
70
⁰
35
6.36
75
⁰
30
5.45
80
⁰
30
5.45
85
⁰
25
4.55
90
⁰
25
4.55
Compound 45
⁰
24
4.36

_______________________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880
Document No. D211-00-251-IS-SC-UL Issue A 22-07-2022 Sheet 2 of 4
2.2 Vertical Light Output Dispersion for wall mounting – public mode
75°
60°
45°
30°
15°
0°
90°
Fig. 2 – Vertical dispersion angles for wall mounting
Table
1B
-
D2xB1XH2
-
Horizontal Light Output Dispersion for Wall Mounting
Viewing Angle
% Of Rating
Intensity (cd) at 1Hz flash rate
0
⁰
100
70.29
5-25
⁰
90
63.26
30-45
⁰
75
52.72
50
⁰
55
38.66
55
⁰
45
31.63
60
⁰
40
28.12
65
⁰
35
24.60
70
⁰
35
24.60
75
⁰
30
21.09
80
⁰
30
21.09
85
⁰
25
17.57
90
⁰
25
17.57
Compound 45
⁰
24
16.87
Table 2A – D2xB1XH1 - Vertical Light Output Dispersion for Wall
Mounting
Viewing
Angle
% Of Rating Intensity (cd) at 1Hz flash rate
0° 100 18.18
5-30° 90 16.36
35°
65
11.82
40°
46
8.36
45°
34
6.18
50° 27 4.91
55°
22
4.00
60° 18 3.27
65° 16 2.91
70° 15 2.73
75° 13 2.36
80-90° 12 2.18

_______________________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880
Document No. D211-00-251-IS-SC-UL Issue A 22-07-2022 Sheet 3 of 4
2.3 Vertical Light Output Dispersion for ceiling mounting – public mode
15°
30°
45°
60°
75°
90°
15°
30°
45°
60°
75°
90°
Fig. 3 – Vertical dispersion angles for ceiling mounting X and Y planes
Table 2B– D2xB1XH2 - Vertical Light Output Dispersion for Wall
Mounting
Viewing
Angle
% Of Rating Intensity (cd) at 1Hz flash rate
0° 100 70.29
5-30° 90 63.26
35° 65 45.69
40°
46
32.33
45°
34
23.90
50° 27 18.98
55°
22
15.46
60°
18
12.65
65° 16 11.25
70° 15 10.54
75° 13 9.14
80-90° 12 8.43
Table 3A– D2xB1XH1 – Vertical Light Output Dispersion for Ceiling Mounting
Viewing Angle % Of Rating Intensity (cd) at 1Hz flash rate
0
⁰
100 18.18
5-25
⁰
90 16.36
30-45
⁰
75
13.64
50
⁰
55 10.00
55
⁰
45 8.18
60
⁰
40
7.27
65
⁰
35 6.36
70
⁰
35 6.36
75
⁰
30 5.45
80
⁰
30 5.45
85
⁰
25 4.55
90
⁰
25 4.55

_______________________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880
Document No. D211-00-251-IS-SC-UL Issue A 22-07-2022 Sheet 4 of 4
All light output ratings min. values as per UL 1971 / UL1638 / CAN/ULC-S526 at worst-case (min.) input voltage.
3) Electrical Ratings
3.1 Surge current for Fire Alarm system use
Table 4 – Surge Currents
Model Nom.
Voltage
Voltage
Range
Flash Rate Setting Peak
Surge current
RMS
surge current
D2xB1XH1DC024 24Vdc 20-28Vdc 1Hz (60fpm) 1.04A 0.437A
D2xB1XH2DC024 24Vdc 20-28Vdc 1Hz (60fpm) 0.992A 0.620A
Table 3B– D2xB1XH2 – Vertical Light Output Dispersion for Ceiling Mounting
Viewing Angle % Of Rating Intensity (cd) at 1Hz flash rate
0
⁰
100 70.29
5-25
⁰
90 63.261
30-45
⁰
75
52.7175
50
⁰
55 38.6595
55
⁰
45
31.6305
60
⁰
40
28.116
65
⁰
35 24.6015
70
⁰
35 24.6015
75
⁰
30 21.087
80
⁰
30 21.087
85
⁰
25 17.5725
90
⁰
25 17.5725

ALL DIMENSIONS IN MM
IF IN DOUBT, ASK -
DO NOT SCALE
2S
warning signals
NTS
D2xB1XH1 & D2xB1XH2 UL1971 PUBLIC MODE FIRE
BEACONS WIRING DIAGRAM
D211-06-251
11
OF
D2x R.N.POTTS
R.S. RAIT
B. ISARD
27-06-2019
27-06-2019
27-06-2019
MOD No. REASON - INITIAL - DATEISSUE
1INTRODUCTION
RSR 02-01-2020
DC XENON D2XB1XH1 / XH2 UNITS
Line Monitoring
Power: +ve & -ve
R1
-
-
+
+
+ve IN
+ve OUT
-ve OUT
-ve IN
EARTH IN
EARTH OUT
E
E
2UPDATED FORMAT
DH 17-05-2022
OPTIONAL LINE MONITORING RESISTOR, CUSTOMER SUPPLIED,
REQUIRED MINIMUM VALUES:
R1
1KΩ MIN, 2W MIN OR 3K9Ω MIN, 0.5W MIN

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: [email protected] www.e2s.com DC-061_Issue_J (D2x).docx - Page 1 of 2 - QAF_252_Issue_5
EU Declaration of Conformity
Manufacturer: European Safety Systems Ltd.
Impress House, Mansell Road, Acton
London, W3 7QH
United Kingdom
Authorised Representative: E2S Warnsignaltechnik UG
Charlottenstrasse 45-51
72764 Reutlingen
Germany
Equipment Type: D2xS1, D2xC1X05, D2xC1X10
D2xB1X05, D2xB1X10, D2xB1LD2, D2xB1XH1, D2xB1XH2, D2xB1LD3
D2xC2X05, D2xC2X10, D2xC2LD2, D2xC2XH1, D2xC2XH2, D2xC2LD3
D2xJ1
Directive 2014/34/EU: Equipment and Protective Systems for use in Potentially Explosive Atmospheres (ATEX)
Notified Body for EU
type Examination
(Module B)
:
UL International Demko A/S
Notified Body No.: 0539
Borupvang 5A, 2750 Ballerup, Denmark
EU
-
type Examination Certificate
(Module B)
:
DEMKO 14 ATEX
4786493904X
Notified Body for Quality Assurance Notification
/ Conformity to EU
-
type
based on
quality assurance of the production process (Module D):
Sira Certification Service
Notified Body No.: 2813
CSA Group Netherlands B.V, Utrechtseweg 310, 6812 AR, Arnhem, Netherlands
Quality Assurance Notification
(Module D)
:
SIRA 05 ATEX M342
Provisions fulfilled by the equipment:
II 3G Ex
ec
IIC
T6/
T4
/T3
/T2/T1 Gc
II 3D Ex tc IIIC Ex tc IIIC T55/75/80/85/90/95/105/110°C Dc
IP66 Ingress / Dust Protection to EN60079-0 / EN60079-31
Standards applied:
EN IEC 60079
-
0:2018
EN IEC 60079-7:2015 +A1:2018
EN 60079-31:2014
Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)
Standards applied:
EN 61000
-
6
-
1:2007
EN 61000-6-2:2005
EN 61000-6-3:2007 / A1:2011 / AC: 2012
EN 61000-6-4:2007 / A1: 2011
Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)
The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic
equipment, including amendment by Directive 2015/863/EU.
Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)
The product and all the components contained within it are free from substances of very high concern.
Other Standards and Regulations
EN 60529:1992+A2:2013 - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: [email protected] www.e2s.com DC-061_Issue_J (D2x).docx - Page 2 of 2 - QAF_252_Issue_5
Martin Streetz Document No.: DC-061_Issue_J
Quality Assurance Manager Date and Place of Issue: London, 22/08/2022
EU Declaration of Conformity
On behalf of European Safety Systems Ltd., I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment
conforms with all technical and regulatory requirements of the above listed directives, regulations and standards.
This Declaration is issued under the sole responsibility of the manufacturer.

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: [email protected] www.e2s.com DC-102_Issue_A - Page 1 of 2 - QAF_252_Issue_5
UKCA Declaration of Conformity
Manufacturer: European Safety Systems Ltd.
Impress House, Mansell Road, Acton
London, W3 7QH
United Kingdom
Equipment Type: D2xS1, D2xC1X05, D2xC1X10
D2xB1X05, D2xB1X10, D2xB1LD2, D2xB1XH1, D2xB1XH2, D2xB1LD3
D2xC2X05, D2xC2X10, D2xC2LD2, D2xC2XH1, D2xC2XH2, D2xC2LD3
D2xJ1
Directive UKSI 2016:1107 (as amended by UKSI 2019:696) – Schedule 3A, Part 1 : Product or Protective System Intended for use in Potentially Explosive Atmospheres
(UKCA)
Notified Body for
UK
type Examination
(Module B)
:
UL International (UK) Ltd
Notified Body No.: 0843
Unit 1‐3 Horizon Kingsland Business Park, Wade Road,
Basingstoke, Hampshire RG24 8AH UK
UK
‐
type Examination Certificate
(Module B)
:
UL21UKEX2131X
Notified Body for Quality Assurance Notification
/ Conformity to EU
‐
type
based on
quality assurance of the production process (Module D):
Sira Certification Service
Notified Body No.: 0518
Rake Lane, Eccleston, Chester CH4 9JN, UK
Quality Assurance Notification
(Module D)
:
CSAE 22UKQAN0046
Provisions fulfilled by the equipment:
II 3G Ex
ec
IIC
T6/
T4
/T3
/T2/T1 Gc
II 3D Ex tc IIIC Ex tc IIIC T55/75/80/85/90/95/105/110°C Dc
IP66 Ingress / Dust Protection to EN60079‐0 / EN60079‐31
Standards applied:
EN IEC 60079
‐
0:2018
EN IEC 60079‐7:2015 +A1:2018
EN 60079‐31:2014
Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)
Standards applied:
EN 61000
‐
6
‐
1:2007
EN 61000‐6‐2:2005
EN 61000‐6‐3:2007 / A1:2011 / AC: 2012
EN 61000‐6‐4:2007 / A1: 2011
Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS)
The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic
equipment, including amendment by Directive 2015/863/EU.
Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)
The product and all the components contained within it are free from substances of very high concern.
Other Standards and Regulations
EN 60529:1992+A2:2013 ‐ Degrees of protection provided by enclosures (IP code) – enclosure rated IP66

E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: [email protected] www.e2s.com DC-102_Issue_A - Page 2 of 2 - QAF_252_Issue_5
Martin Streetz Document No.: DC‐102_Issue_A
Quality Assurance Manager Date and Place of Issue: London, 22/08/2022
UKCA Declaration of Conformity
On behalf of European Safety Systems Ltd., I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment
conforms with all technical and regulatory requirements of the above listed directives, regulations and standards.
This Declaration is issued under the sole responsibility of the manufacturer.
Other manuals for D2xB1XH1
1
This manual suits for next models
1
Table of contents
Other E2S Lighting Equipment manuals

E2S
E2S MC1LD2FDC024 User manual

E2S
E2S AlertAlight AL121H User manual

E2S
E2S BExCBG05-05D-P User manual

E2S
E2S BExTBG05D-P User manual

E2S
E2S Spectra H100 TF User manual

E2S
E2S BExBGL2D-P User manual

E2S
E2S BExBG21D User manual

E2S
E2S D2xB1X05 Series User manual

E2S
E2S GNExB1X05 User manual

E2S
E2S E2xBL2 User manual