manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. EasyPro
  6. •
  7. Water Pump
  8. •
  9. EasyPro TB Series Operation and maintenance manual

EasyPro TB Series Operation and maintenance manual

800-448-3873 • Grant, Michigan
www.easypro.com • info@easypro.com
TB Series
Submersible High Head
Waterfall Pumps
Instructions for Operation • Safety • Warranty
Designed for use with higher head pressure
TB8000 • TB8002 • TB12000 • TB14500
Thank you for purchasing the TB series waterfall pump.
This instruction manual explains the product operations
and gives important precautions regarding its safe
use. In order to use the product to maximum benet,
be sure to read the instructions thoroughly and follow
them carefully.
Specications
• 3" outlets
• Automatic thermal overload protection
• Double silicone carbide mechanical seals with
100,000 hour life expectancy
• TB8000 available as 230v or 115v, TB12000 and TB14500 available
as 230v only
• Two year limited warranty
• A minimum of 20' head pressure required for TB12000 and TB14500
70'
60'
50'
40'
30'
20'
10'
0'
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000
TB14500
TB12000
TB8000
GPH
GPM
Feet of Head
|
20
|
40
|
60
|
80
|
100
|
120
|
140
|
160
|
180
|
200
|
220
Beyond operating capacity Best efficiency
Replacement Parts
No. Description Material
1 Cord B Series Pumps
2 Motor Casing Stainless Steel 304
3 Motor Cover Die Casting FC-200
4 Bearing NBR
5 Motor Shaft Stainless Steel 403
6 Mechanical Seal Silicone Carbide & Ceramic
7 Impeller Die Casting FC-200
8 Pump Base Die Casting FC-200
9 Handle Stainless & NBR
10 Discharge PE & Die Casting FC-200
10
9
8
7
6
5
4
3
2
1
5454 • 10/19
EasyPro Pond Products Limited Warranty
EasyPro Pond Products (“EasyPro”) warrants to the purchaser that this
product (TB Series Submersible High Head Waterfall Pump) will be free
from any mechanical or material defects for a period of two years from
the date of purchase. This warranty does not cover accidental damage to
the product due to abuse or negligence by the consumer. This warranty
only covers properly installed and maintained Products sold by authorized
EasyPro Sellers who are subject to and follow EasyPro’s quality control
standards. Please note that because EasyPro is unable to control the
quality of Products sold by unauthorized sellers, unless otherwise
prohibited by law, this warranty does not cover Products purchased from
unauthorized sellers.
This warranty does not cover normal wear and tear, nor any deterioration
suered through overloading, improper use, negligence, improper
installation, acts of God or accident. Similarly, any modication made by
the purchaser to the Product will cause the warranty to be null and void.
This warranty does not cover any cost associated with the installation or
removal of the Product subject to a warranty claim.
All returned items will be inspected to determine cause of failure
before a warranty claim is approved. The exclusive remedies provided
hereunder shall, upon EasyPro’s inspection and option, be either repair
or replacement of the Product or parts covered under this warranty.
Making a Claim: A Return Authorization (“RA”) number must rst be obtained
by calling EasyPro at 800-448-3873 or via email at [email protected].
It is the purchaser’s responsibility to pay the return shipping charges. Be sure
to include the RA number, original receipt (in the form of an invoice or sales
receipt), your name, your return address and your phone number inside of
the package. No warranty claims will be honored without the original receipt
that shows that your purchase was made from an Authorized EasyPro Seller.
Ensure the product is properly packaged and insured for the replacement
value. Damage due to improper packaging is the responsibility of the sender.
ALL OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING
MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE ARE
HEAREBY LIMITED IN DURATION TO THE DURATION OF THE WARRANTY
AS DESCRIBED ABOVE. Some States do not allow limitations on how long
an implied warranty lasts, so the above limitations may not apply to you.
EasyPro shall not be held liable for any damages caused by defective
components or materials of this Product; or for loss incurred because of
the interruption of service; or any consequential/incidental damages and
expenses arising from the production, sale, use or misuse of this Product.
Some States do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply
to you.
EasyPro shall not be held liable for any loss of sh, plants or any other
livestock as a result of any failure or defect of this Product. This warranty
gives you specic legal rights, and you may also have other rights that vary
from State to State.
Volts/ Max Max
Model HP Max Amps Weight Head Flow
TB8000 1 115/10.9 43 lbs. 40' 8000 GPH
TB8002 1 230/5.5 43 lbs. 40' 8000 GPH
TB12000 2 230/9.7 64 lbs. 60' 12000 GPH
TB14500 3 230/14.5 72 lbs. 72' 14500 GPH
Units have 20' power cords
Safety & Electrical Connections
WARNING: Verify that the voltage and frequency of the electric
pump shown on nameplate correspond to those available on mains.
• The installer must make sure that the electric system is grounded in
accordance with local ordinances.
• The plug and connections should be protected from water/rain.
Before using the pump, always inspect it visually (especially power
cable and plug).
• Do not use the pump if it is damaged. If the pump is damaged, have it
inspected by a qualied service center only.
• Make sure electric connections are protected from all water and
moisture. Protect plug and the power cable from heat, oil or sharp
edges.
WARNING: The power cable must be replaced by qualied
personnel only.
Grounding: The plug of the power cable has a double grounding contact,
so that grounding can be performed by simply inserting the plug.
Overload Protection: EasyPro pumps have a built in thermal protection
switch. The pump stops if an overload condition occurs. The motor
restarts automatically after it has cooled down.
Prior to Operation
Check the following points upon receipt of your pump:
• Is the pump exactly what you ordered? Check nameplate.
• Has any damage occurred during shipment?
• Are any bolts or nuts loose?
• Have all necessary accessories been supplied?
• We recommend that you keep a spare pump on hand in case of
emergencies. Keep this instruction manual in a place for future
reference.
Installation
Limitations:
This pump must stay submerged entirely when operating. If used in
skimmer, the debris net must be kept clean to ensure adequate water
ow to the pump. Running pump low on water will cause overheating and
premature failure which is not covered under warranty.
This series of pumps are suitable to pump water and also can be used
both for permanent and temporary installation. The pump can be placed
in a sump pit, then can pump dirty water containing suspended solid
particles up to 1/2" diameter.
WARNING: The pump cannot be used for sea water, chlorinated
water and ammable, corrosive, explosive or dangerous liquids.
Installation:
WARNING: Do not work on pump until power is unplugged.
Do not cut o ground pin or use an adapter tting.
Do not use an extension cord
Must be used on a GFCI protected outlet
Do install the strainer prior to using if you want to let the pump run as a
sump pump.
The pump power cord should be connected to a separately fused,
grounded line with a minimum capacity of 15 amps. It can be connected
to non- fuse breaker at the recommended amps. Never touch the pump
when it is plugged in.
1. Before installing or servicing this pump, be certain pump power
source is disconnected. Contact a qualied licensed electrician for
disconnecting electrical service prior to pump removal.
2. Installation and electrical wiring must adhere to state/local codes
and must be completed before priming pump. Check appropriate
community agencies, or contact local electrical and pump
professionals.
3. Call an electrician when in doubt. Pump should be connected to
a separate 15 amp circuit breaker or 15 amp fuse block. Note that,
plugging into existing outlets may cause low voltage at motor, causing
blown fuses, tripping of motor overload or burned out motor.
4. A permanent ground connection from pump to the grounding bar at
the service panel is mandatory. For maximum safety, connect pump
to a circuit equipped with a Ground Fault Circuit Interrupter device
when you position the pump’s grounding wire.
5. Voltage of power supply must match the voltage of the pump.
WARNING: Must be vented in accordance with local plumbing codes.
EasyPro pumps are not designed for and CANNOT be installed in
locations classied as hazardous.
WARNING: The following may cause severe damage to pump and
will void warranty:
• Using an extension cord
• Cutting o the ground pin or using an adapter tting
• Working on pump or switch while plugged in
• Removing motor housing, unscrewing impeller or otherwise removing
impeller seal
•
Pumping chemicals or corrosive liquids including chlorinated or salt water
• Pumping gasoline or other ammable liquids
• Piping: Plastic PVC pipe, drain hose, galvanized steel or copper pipe
may all be used. All piping must be clean and free of all foreign matter
to prevent clogging. Be sure to seal the thread connection with tape
seal when you are using the pipe tting to connect the ange.
TB High Head Pump Trouble Shooting
Humming • Line circuit breaker is o, fuse is burned or loose
• Pump cord is not making contact in receptacle
• Float (optional) is stuck, it should operate freely
• May have air lock
Running, no water • Check valve (optional) is installed backwards
• Discharge shut-o valve closed
• Inlet or impeller clogged
• Pump is air-locked, start and stop several times
by plugging and unplugging cord, check for
clogged
vent hole, may need to disconnect and
reinstall pump.
• Inlet holes in pump base are clogged, remove pump
and clean the openings.
• Vertical pumping distance is too high or the pipe
size is too small, reduce vertical distance or
increase the pipe size ttings.
Running, very • Pump is air-locked, start and stop several times by
little water plugging and unplugging cord, check for clogged
vent hole
• Vertical pumping distance is too high or the pipe
size is too small
• Inlet or impeller clogged/damged
• Low water conditions with pump sucking air
GFCI breaker • Fuse size or circuit breaker may be too small.
tripping • Motor stator may be defective
• Pump impeller or inlet is partially clogged with
debris
Motor briey • Low water conditions, pump overheating
starts and stops • Inlet or impeller clogged
• Improper power supply
• Motor stator may be defective
Each year we receive numerous pumps back that simply have a small
stone lodged in the impellar, are plugged from lack of cleaning or do not
work due to low voltage caused by an overloaded circuit. These are not
warranty items. Please take the time to verify your problem is actually
a defective pump before returning. EasyPro will pay postage to return
pump to you provided it is a warranty issue. If you send a pump in for
warranty and it checks out ne — you will also be responsible for the
cost of return postage.

This manual suits for next models

4

Other EasyPro Water Pump manuals

EasyPro TH Series Operation and maintenance manual

EasyPro

EasyPro TH Series Operation and maintenance manual

EasyPro TM Series Use and care manual

EasyPro

EasyPro TM Series Use and care manual

EasyPro EXP8700-2 Series Manual

EasyPro

EasyPro EXP8700-2 Series Manual

EasyPro EX6750-2 Manual

EasyPro

EasyPro EX6750-2 Manual

EasyPro ESF1250 User manual

EasyPro

EasyPro ESF1250 User manual

EasyPro EX3600 Manual

EasyPro

EasyPro EX3600 Manual

EasyPro TS150 User manual

EasyPro

EasyPro TS150 User manual

EasyPro EX4500 Manual

EasyPro

EasyPro EX4500 Manual

EasyPro ETP05N Operation and maintenance manual

EasyPro

EasyPro ETP05N Operation and maintenance manual

EasyPro ES1250 User manual

EasyPro

EasyPro ES1250 User manual

EasyPro EXT Series Manual

EasyPro

EasyPro EXT Series Manual

EasyPro Tranquil Decor User manual

EasyPro

EasyPro Tranquil Decor User manual

EasyPro TM Series Use and care manual

EasyPro

EasyPro TM Series Use and care manual

EasyPro PCA75 Manual

EasyPro

EasyPro PCA75 Manual

EasyPro EXP4000 Manual

EasyPro

EasyPro EXP4000 Manual

EasyPro EPS650 Use and care manual

EasyPro

EasyPro EPS650 Use and care manual

EasyPro TB Series Operation and maintenance manual

EasyPro

EasyPro TB Series Operation and maintenance manual

EasyPro TM Series Use and care manual

EasyPro

EasyPro TM Series Use and care manual

EasyPro EXP3200 Manual

EasyPro

EasyPro EXP3200 Manual

EasyPro EXP3700 Manual

EasyPro

EasyPro EXP3700 Manual

EasyPro EP120 Use and care manual

EasyPro

EasyPro EP120 Use and care manual

Popular Water Pump manuals by other brands

Graco Lube Pro 24Z020 instructions

Graco

Graco Lube Pro 24Z020 instructions

GEA Hilge HYGIA H ADAPTA operating instructions

GEA

GEA Hilge HYGIA H ADAPTA operating instructions

Robin America PKX Series Robin Pump 201 Instructions for use

Robin America

Robin America PKX Series Robin Pump 201 Instructions for use

AquaKing RED LABEL 2 manual

AquaKing

AquaKing RED LABEL 2 manual

Interpump General Pump EV Series Repair manual

Interpump

Interpump General Pump EV Series Repair manual

SHURflo 3000 Installation and operation manual

SHURflo

SHURflo 3000 Installation and operation manual

flamco Flamcomat Starter Installation and operating instuction

flamco

flamco Flamcomat Starter Installation and operating instuction

Deming 4021H Installation, operation & maintenance manual

Deming

Deming 4021H Installation, operation & maintenance manual

KSB RPH Installation & operating manual

KSB

KSB RPH Installation & operating manual

XPOtool 62820 Operation manual

XPOtool

XPOtool 62820 Operation manual

World Chemical SUBMERSE YD-GWN Series instruction manual

World Chemical

World Chemical SUBMERSE YD-GWN Series instruction manual

Legacy Performance L3510 Owner's instructions

Legacy

Legacy Performance L3510 Owner's instructions

KNF N680 EX manual

KNF

KNF N680 EX manual

Alemlube 51000 Service instructions

Alemlube

Alemlube 51000 Service instructions

Pentair IntelliFlo Operation and Set Up Instructions

Pentair

Pentair IntelliFlo Operation and Set Up Instructions

Grundfos MQ 3-25 Installation and operating instructions

Grundfos

Grundfos MQ 3-25 Installation and operating instructions

WITA Adelino QX Service manual

WITA

WITA Adelino QX Service manual

Allfett ALL-5 Two Line INTRODUCTION AND USER MANUAL

Allfett

Allfett ALL-5 Two Line INTRODUCTION AND USER MANUAL

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.