Eaton SPD150i User manual

Specifications are subject to change without notice. Copyright 2015 Eaton Industries, Mascot. NSW.
Technical Specification SPD150i Doc# 5100SPD150i Rev1
Page 1 of 2
TECHNICAL SPECIFICATION AND
INSTALLATION GUIDE
SPD150i SURGE DIVERTER
( IEC61643-11 Class I & II, 150kA, 2 mode, 220-
300vac, L-E or L-N )
APPLICATIONS
Primary power circuits
Telecommunication Systems / Rectifiers
Process and Control Systems
Computer Systems / Medical Systems
FEATURES
Patented MTMOV technology
( Failsafe thermal disconnect )
UL1449 ed3 Type 4 listed components
150kA, 2 mode, L-N or L-E
UL94-V0 ABS din rail mount housing
Din 43880 form factor 4 din wide
Dry contact alarm
LED visual indicators for protection,
power and fault conditions.
FUNCTIONAL DESCRIPTION
The SPD150i is designed to protect single and three
phase power systems against damage from surges
and spikes caused by lightning and other electrical
sources. The unit is intended for point of entry or
main board protection and is connected in parallel
with the power system via HRC fuses.
This model ( SPD150i ) is designed for use in
systems with a grounded neutral in L-N mode. If
your system does not have a grounded Neutral or
is of a different voltage, this model is NOT
suitable.
OPERATION
Indicators - The operation status of the SPD150i is
indicated by leds on the front panel. The ‘OK’ ( blue )
light indicates that power is applied to the SPD150i
The ‘FAULT’ light ( red ) indicates that the surge
protection circuitry is damaged and the unit should be
replaced. The additional 3 leds ( blue ) indicate the
status of each MOV element. When the fault indicator
lights, the protection relay contacts change over. The
power failure alarm will operate when mains voltage
falls below 180VAC.
PHYSICAL AND ELECTRICAL SPECIFICATIONS
Model SPD150i
Number of ports 1 Port
Method of mounting Fixed. DIN Rail mount
Input voltage – Uc 220-300vac 1P, 380-
480vac 3P
Maximum continuous voltage –
MCOV 320 L-N, L-E
Temporary overvoltage - TOV 350VAC L-N, 15 mins
Service type TT, TN, TN C-S or any 1 or
3phase system with a
grounded neutral.
Test classification (IEC61643-11) Class II
Maximum over current protection 125A
Protection modes Line-Neutral, Line-Earth
Inom 8/20us (Line-Neutral/Earth).
Nominal surge life. 60kA
Imax 8/20us (Line-Neutral/Earth).
Maximum surge level. 120kA
Residual voltage (Vpl) (Line-
Neutral/Earth). (Let through
voltage)
<1000v (3kA, 8/20us,
( IEC61643-11)
Safety disconnect Series thermal fusing on
MOV’s
External disconnector
requirement Max 125A HRC fuse
Terminations Power 16mm2
Alarms/indicators
5 LED display, dry
contact alarm relay
output – 250VAC/32VDC,
5A, 5kV isolation
Enclosure rating IP20
Standards. Designed in
accordance with :
IEC61643-11, ANSI/IEEE
C62.41 Cat A & B,
AS1768-2007 Cat A & B,
UL1449ed3 type 4
Installation instructions Supplied with unit.
Dimensions 70W x 58D x 90H (mm)
Weight 200g
Environment -10 to 60C, 0 to 95%RH
(non-condensing)
Warranty 5 years, workmanship
and materials
Specifications are subject to change without notice. Copyright 2015 Eaton Industries, Mascot. NSW.
Technical Specification SPD150i Doc# 5100SPD150i Rev1
Page 2 of 2
INSTALLATION
Refer to the following procedure to connect the
SPD150i.
1. CHECK
Always work safely-disconnect power before
making connections.
All wiring must be carried out by suitably
qualified personnel according to applicable
standards.
For installation adjacent to an M.E.N. link,
use the L-N mode. Insert insulated link as
shown.
For installation remote from the M.E.N. link,
use the L-E mode. Remove link. A separate
N-E protector may be required.
Always use correct size HRC fuses.
For services >125A use 125A HRC fuses.
For services <125A use 1 step below service
size. DO NOT USE AN MCB.
Always use Gg or Gl rated fuses. Do not use
delay types or semiconductor fuses.

2. INSTALL
Locate fuse position as close as possible to
the Main Switch.
Install fuse holders or fuse switch.
Locate suitable position for SPD ensuring
adequate space for cables. Do not install
above heat generating objects or any
position exposed to weather.

3. CONNECT
Connect wiring-refer to connection diagram
on this page. Always use bootlace wire
ferrules for lowest resistance to prevent
damage to wire.
Use suitably rated cable for power
connections. Cable should be rated for
operation at system voltage and be 4mm to
16mm sq.
Use shortest possible cables for all
connections or protection will be reduced.
For alarm cables use cable rated at system
voltage at between 0.5-1.5mm2.

3. NOTES
125A fuses are rated for maximum surge
rating.
Wiring from fuse to SPD carries surge
currents only. This means lower size cables
can be used than service size rating.
If using undersize cables we recommend
double insulating same.
It is recommended NOT to connect alarm
contacts to AC mains circuits if possible, to
prevent flashover from surges on AC line.
Connect to a BMS or PLC if possible.
Do not perform an insulation resistance test
on this unit as it contains voltage limiting
components which may be damaged during
testing.
3. EARTHING
The main earth wire (from earth link on
switchboard to ground rod or system ) MUST
be at least 6mm dia or larger.
Earth connections from the unit to neutral or
earth link MUST be as short as possible.
Failure to comply with the above points
can result in improper operation of the
unit and possible damage to the
installation.
L-N mode connections
L-E mode connections

Other Eaton Industrial Equipment manuals

Eaton Power Defense LFD User manual

Eaton

Eaton Power Defense LFD User manual

Eaton PKE-SWD-SP Manual

Eaton

Eaton PKE-SWD-SP Manual

Eaton Crouse-hinds series User manual

Eaton

Eaton Crouse-hinds series User manual

Eaton P3-30/EA/SVB-MCS Manual

Eaton

Eaton P3-30/EA/SVB-MCS Manual

Eaton MSC-D M11-PI Series Manual

Eaton

Eaton MSC-D M11-PI Series Manual

Eaton DILH1200/22 Manual

Eaton

Eaton DILH1200/22 Manual

Eaton Airflex WCB Series Installation and operating instructions

Eaton

Eaton Airflex WCB Series Installation and operating instructions

Eaton Z-LHASA Guide

Eaton

Eaton Z-LHASA Guide

Eaton AGM2-10-PKZ0 Manual

Eaton

Eaton AGM2-10-PKZ0 Manual

Eaton Xcomfort CSEZ-01/13 User manual

Eaton

Eaton Xcomfort CSEZ-01/13 User manual

Eaton RVAC Technical manual

Eaton

Eaton RVAC Technical manual

Eaton GROUSE-HINDS AB 05 Ex-nR User manual

Eaton

Eaton GROUSE-HINDS AB 05 Ex-nR User manual

Eaton MMX-NET-XA Manual

Eaton

Eaton MMX-NET-XA Manual

Eaton AM-4.16-GT User manual

Eaton

Eaton AM-4.16-GT User manual

Eaton P3 Z Series Manual

Eaton

Eaton P3 Z Series Manual

Eaton Powerware SPD3Gi/A User manual

Eaton

Eaton Powerware SPD3Gi/A User manual

Eaton AT4 Manual

Eaton

Eaton AT4 Manual

Eaton 2596 Instruction manual

Eaton

Eaton 2596 Instruction manual

Eaton DILM80 170XCT Series Manual

Eaton

Eaton DILM80 170XCT Series Manual

Eaton PDI WaveStar TFA STS 250-600A User manual

Eaton

Eaton PDI WaveStar TFA STS 250-600A User manual

Eaton NZM2-XAP7 Manual

Eaton

Eaton NZM2-XAP7 Manual

Eaton MTL770 Series User manual

Eaton

Eaton MTL770 Series User manual

Eaton Vickers EHH-AMP-702-D-10 Manual

Eaton

Eaton Vickers EHH-AMP-702-D-10 Manual

Eaton SL7-CB-D-M12A4 Manual

Eaton

Eaton SL7-CB-D-M12A4 Manual

Popular Industrial Equipment manuals by other brands

ABB +Q957 user manual

ABB

ABB +Q957 user manual

G.B.C BASIC EDGE 50 instruction manual

G.B.C

G.B.C BASIC EDGE 50 instruction manual

Tronair Batpak 11-6602-1000 Operation & service manual

Tronair

Tronair Batpak 11-6602-1000 Operation & service manual

Pilz PNOZ mi2p Operation manual

Pilz

Pilz PNOZ mi2p Operation manual

Clemco Zero BNP 6012 manual

Clemco

Clemco Zero BNP 6012 manual

Erskine Attachments V-Plow Operator's manual

Erskine Attachments

Erskine Attachments V-Plow Operator's manual

ABB HT610965 Operation manual

ABB

ABB HT610965 Operation manual

Morra MH 540 user manual

Morra

Morra MH 540 user manual

GRIGGIO G 240 P4 instructions

GRIGGIO

GRIGGIO G 240 P4 instructions

Nexen AIR CHAMP HT45 user manual

Nexen

Nexen AIR CHAMP HT45 user manual

WTE V5 installation manual

WTE

WTE V5 installation manual

ABB HT845232 Operation manual

ABB

ABB HT845232 Operation manual

SMC Networks CJP Series Operation manual

SMC Networks

SMC Networks CJP Series Operation manual

JohnDow Industries JDI-AFT58 Operator's manual

JohnDow Industries

JohnDow Industries JDI-AFT58 Operator's manual

IMB MB9016A instruction manual

IMB

IMB MB9016A instruction manual

Clarke CUMB1 Assembly & operating instructions

Clarke

Clarke CUMB1 Assembly & operating instructions

amiad Arkal Spin Klin 2 user guide

amiad

amiad Arkal Spin Klin 2 user guide

Maxima GIUNTOMAX Use and maintenance manual

Maxima

Maxima GIUNTOMAX Use and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.