manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Eaton
  6. •
  7. Measuring Instrument
  8. •
  9. Eaton PXBCM-MB Manual

Eaton PXBCM-MB Manual

This manual suits for next models

2

Other Eaton Measuring Instrument manuals

Eaton CMD User manual

Eaton

Eaton CMD User manual

Eaton InsulGard User manual

Eaton

Eaton InsulGard User manual

Eaton MGR10 User manual

Eaton

Eaton MGR10 User manual

Eaton Powerware Environmental Rack Monitor User manual

Eaton

Eaton Powerware Environmental Rack Monitor User manual

Eaton E5024E0432 User manual

Eaton

Eaton E5024E0432 User manual

Eaton PDI WaveStar Infinity 2 Manual instruction

Eaton

Eaton PDI WaveStar Infinity 2 Manual instruction

Eaton SEFELEC 1500M User manual

Eaton

Eaton SEFELEC 1500M User manual

Eaton RMD User manual

Eaton

Eaton RMD User manual

Eaton IQ 150S Guide

Eaton

Eaton IQ 150S Guide

Eaton xStorage Home Series User manual

Eaton

Eaton xStorage Home Series User manual

Eaton 1MM User manual

Eaton

Eaton 1MM User manual

Eaton CMD Manual

Eaton

Eaton CMD Manual

Eaton Durant Eclipse Series User manual

Eaton

Eaton Durant Eclipse Series User manual

Eaton IQ 250 Guide

Eaton

Eaton IQ 250 Guide

Eaton Cutler-Hammer Enclosed IQ Manual

Eaton

Eaton Cutler-Hammer Enclosed IQ Manual

Eaton Crouse-hinds series User manual

Eaton

Eaton Crouse-hinds series User manual

Eaton Crouse-hinds series User manual

Eaton

Eaton Crouse-hinds series User manual

Eaton IQ 250 Guide

Eaton

Eaton IQ 250 Guide

Eaton Power Xpert Meter 2000 User manual

Eaton

Eaton Power Xpert Meter 2000 User manual

Eaton GIM 60 User manual

Eaton

Eaton GIM 60 User manual

Eaton Cutler-Hammer Manual

Eaton

Eaton Cutler-Hammer Manual

Eaton Durant Eclipse Series User manual

Eaton

Eaton Durant Eclipse Series User manual

Eaton LifeSense User manual

Eaton

Eaton LifeSense User manual

Eaton 5775X-42X User manual

Eaton

Eaton 5775X-42X User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Effective May 2019
Supersedes February 2015
PXBCM-MB-BASIC
PXBCM-MB-ENERGY
Instruction Leaflet IL150001EN
Power Xpert Branch Circuit Monitor:
Meter Base - Basic and Energy Code Series
COM reset
button
Base mounting
screws #8
LED Indicators
Configuration
switches
Com1/2 RS485
Modbus RTU
LAN Ethernet
RJ45 CAT5+
STP
MMP 1-4 Meter
Module ports
Power Supply MainsTerminal PE/N/L Base mounting
screws #8
Figure 1. PXBCM-MB controls, connectors and indicators.
The PXBCM-MB is the data acquisition module/
gateway of the PXBCM system. The PXBCM-
MB aggregates the meter data from up to four
PXBCM-MMS and PXBCM-MME meter modules.
You can access the data from all channels (includ-
ing virtual meters) through the RS485 COM1 or
COM2 Modbus port using the RS-485 RTU proto-
col, or the LAN Modbus TCP connection, or view it
directly through the onboard web server.
The Modbus address is set through a pair of
rotary switches (Address H-L) on the front of the
PXBCM-MB housing. Indicator lights show device
status (Status) as well as communications sta-
tus for both LAN Ethernet and COM1 or COM2
Modbus. A mode switch determines user access
security levels.
The PXBCM-MB must be housed in an appropriate
NEMA or UL enclosure that ensures the device
will remain within its specified environmental
ranges and provides fire and mechanical protec-
tion. In retrofit panel board applications the MB
must be mounted in an enclosure external from
the monitored assembly gear, unless the MB is an
approved accessory for the panel board.
Each Meter Module has the following LED
Indicators
• COM1 or COM2 Rx/Tx Green/Red LEDs –
RS485 Modbus
• MMP 1-4 Rx/Tx Green/Red LED – Meter
Module Port communications
• LAN Ethernet LEDs in RJ45 jack
• Link Green on = Link Active, blink for TxRx
• 10/100 Speed - Amber off/on
• Status Green/Red bicolor LED –
• Green ~ 1Hz blink – Normal heart beat
• Red – Application alarm
• Com Status: Green/Red bicolor LED:
• Green on = DHCP, Green off = Fixed IP
• Red on = communications reset mode
PXBCM-MB Meter Base
Specifications
• Weight ~ 1 lb
• W/H/D: 7.0”(17.6 cm)/6.3”(15.8cm)/2.6”(6.6cm)
• Each Meter Base can interface to 1-4 Meter
Modules (-MMS &/or –MME)
• Housing NEMA 1, IP20
• Pollution Degree 2
• Operational Temperature range -20 to +70ºC
• Storage Temperature range -45 to +85ºC
• Elevation 0-3000m
•WARNING!
BE SURE THAT ALL SYSTEM POWER IS OFF WHEN COMMISSION-
ING A PXBCM SYSTEM INCLUDING THE INSTALLATION OF THE
PXBCM-MB METER BASE AND ASSOCIATED COMPONENTS.
Overview
For use with the Power Xpert Branch Circuit Monitor (PXBCM) Basic and
Energy Code Series meter bases (MB) - Both the PXBCM-MB-BASIC meter
base and PXBCM-MB-ENERGY meter base are designed to be used with
the PXBCM–MME Meter Module External and/or – MMS Meter Module
Strip. The Meter Base (MB) sources power to and collects data from the
Meter Modules through the Meter Module Ports and Cables.
• PXBCM-MMS-(L/R 9/15/21)-A Meter Module Strip
• PXBCM-MME-X25-333MV Meter Module for External CTs
• PXBCM-MME-X21-100MA Meter Module for External CTs
• PXBCM-MMP-CBLnn/-CBLEnn Meter Module Port Cable and Cable
Extension
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
© 2019 Eaton
All Rights Reserved
Printed in USA
Publication No. IL150001EN / TBG001446
May 2019
Eaton is a registered trademark.
All other trademarks are property
of their respective owners.
Power Xpert Branch Circuit Monitor:
Meter Base - Basic and Energy Code Series
Instruction Leaflet IL150001EN
Effective May 2019
• Humidity 5-95% noncondensing
• UL file # E185559, UL Standard UL61010-1
• CNL evaluation to CAN/C22.2 No 1010.1.92
• CE mark
• EMC EN61326 – IEC61000-4-X level 3
• Emissions conducted and radiated as part of PXBCM system.
• FCC part 15 class B
• CISPR 11/22 class B
External Circuit Connections
• Com1/2 RS485 Modbus Slave RTU:
• 9600 – 115.2K(default) baud
• –D, +D, Com/Shield
• Use RS485 cable – 4K’=<19.2Kb,2K’ above
• LAN Ethernet RJ45 CAT5 10/100 base T
• Use STP Cat5+ for full EMC compliance
• MMP1-4 Meter Module ports:
• 2 pair cable 1 pair power, 2nd coms
• Use PXBCM-MMP-CBLnn –CBLEnn cables
• Each MMP is separately isolated
• Power Supply mains 100-277VAC L:N
• Up to 347 VAC L:N possible with control power transformer
• +/-10%, CAT III, 47-63 Hz , 6W
• Double insulated
• 320VAC Surge filter clamp L:N, L:G, N:G - Do not high pot!
• Provide external line fuse or breaker sized to protect wiring
• 3 position fixed terminal block 1/2/3 = PE/N/L, supporting 12
AWG (2.5mm) wire.
A detailed product identification label is on the left side of each
Meter Base. This information can also be viewed through the
PXBCM web configuration with a browser via the LAN Ethernet port.
Figure 2. Example PXBCM-MB Product ID Label.
The MB may be pow-
ered through a single-
phase connection to
the panel mains. The
power connection
(marked Power Supply
on the MB) must be
equipped with both a
disconnect switch and
fuse or breaker to pro-
tect the wire.
Protective
earth
Neutral
Fuse block
Line
Disconnect
switch
Com1 RS485
Modbus RTU
LAN Ethernet
RJ45 CAT5+ STP
MMP 1-4 Meter
Module ports
Figure 3. PXBCM-MB external circuit connections.
Please refer to the PXBCM Install Guide
IB150003EN for complete system detail: www.
eaton.com/pxbcm
Figure 4. Meter Base mounting details.
5.65 in
(143.5 mm)
5.5 in
(139.7 mm)
Com2 RS485
Modbus RTU