PXES4P Switches Installation and User Guide (10/06)
10
Cooling Method: The case is used as a heat sink on this model.
POWER SUPPLY :
These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked
“Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output
voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current (i.e. 100mA to
500mA).When connected to a 48 V centralized dc source these products shall be provided
with a Listed 5 A DC fuse in the supply circuit.
UL listed class II Power Supply, ( AC External):
Power input (8-15)V DC, jack is 2.5mm center +ve , with 6ft. cord
Input: 120vac at 60 Hz for “d” models, 240vac at 50Hz for “i” models that have IEC320
power connector built-in the PS unit. Out put- 12vdc, 1 Amps
Input: 100-240V AC at 47-63Hz, for “-Hd” high temp., 100-240V AC at 47-63Hz “-for
Hi” models that have IEC320 power connector built-in the PS unit.
Out put- 12vdc, 1.25 Amps
PXES4P Switches Installation and User Guide (10/06)
Input: 100-240V AC at 47-63Hz, for “-Pd” high temp. 100-240V AC at 47-63Hz, “-Pi”
models that have IEC320 power connector built-in the PS unit.
Out put- 12vdc, 2 Amps
DC to unit: 12V DC, 2.5mm jack, center +ve, 6ft. cord
Power Supply ( Direct DC ): built-in screw terminal
block for +, -, ground. The 12V DC jack is also
present.
12V DC internal (range of 8.0 to 15V DC),
24V DC internal (range of 18 to 36V DC)
-48V DC internal (range of 36 to 60V DC) t.
Power Consumption: 3 watts typical, 4 watts max.
Note 1: 8-15V DC can be used for dual source DC input
11
PXES4P Switches Installation and User Guide (10/06)
12
Note 2: Internal DC power floats, user may ground “+” or “-” if desired.
Port Connectors:
RJ-45 Port: Auto-cross(MDIX), 100BASE-TX and 10BASE-T:shielded 8-pin
female. Three RJ-45 ports provided in front, and one on the rear. Supports shielded
(STP) and unshielded (UTP) Cat 3, 4, 5 cable.
LED Indicators (Dual- front and end, port #4 has front only)
POWER: Steady ON when power applied (PXES4P model)
10/100: = 100Mbps; OFF = 10 Mbps
LK/ACT: Steady ON for LINK with no traffic, blinking indicates port
is transmitting / receiving.
F/H: ON = full-duplex, OFF = half-duplex
Mounting option for PXES4P Family of Switches: