MASTER/SLAVE CONTROL
The MASTER functions as a master as long as it’s not in DMX mode (and ideally no cable plugged into the DMX
more than 20 lamps or 60m of DMX cable.
Only one light can be set as a master, but multiple lights can be set as slaves.
CABLE CONNECTION
A standard XLR connection is used for the DMX 512 protocol:
DMX512 does not include automatic error checking and correction, and so is not an appropriate control for
electromagnetic interference, static electricity discharges, improper cable termination, excessively long cables, or
poor quality cables.
NOTE
In order to avoid failures and signal interference, it is
recommended to connect a 120Ω resistor (1/4W) at
the end of the DMX connection as shown on right. If
using 5-pin DMX, please use a
5-pin to 3-pin cable adapter. Details on
configuration below:
Termination reduces signal errors and avoids
signal transmission problems and interference. It
is always advisable to connect a DMX terminal,
(Resistance 120 Ohm 1/4 W) between PIN 2
1
2
3
3-PIN XLR to 5-PIN XLR Conversion
Conductor
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
PIN 1
PIN 2
PIN 3
Not Used
Not Used
PIN 1
PIN 2
PIN 3
Do Not Use
Do Not Use
3-PIN XLR Female (Out) 5-PIN XLR Male (In)