Operating Guide
900 Series Dispenser
US: 800-556-3484 In the UK: 0800 585733 In Mexico: 001-800-556-3484
900 900-15 900-CA
••

☎
2
Introduction
The 900 Series fluid dispensers provide years of trouble-free,
productiveservice. ThisOperatingGuidewillhelpyoumaximizethe
usefulness of your new dispenser.
Pleasespendafewminutestobecomefamiliarwiththecontrolsand
features of your new dispenser. Follow our recommended testing
procedures. Reviewthehelpfulinformationwehaveincludedbased
on over 30 years of industrial dispensing experience.
MostquestionsyouwillhaveareansweredinthisGuide. However,
ifyouneedassistance,pleasedonothesitatetocontactEFDoryour
authorized EFD distributor.
In the US, call 800-556-3484.
In Mexico, call 001-800-556-3484.
In the UK, ring free 0800 585733.
The EFD Pledge
We pledge that you will be completely satisfied with our products.
We endeavor to ensure that every EFD product is produced to our
no-compromise quality standards.
If you feel that you are not receiving all the support you require,
orifyou haveanyquestions orcomments,Iinviteyou towriteorcall
me personally.
Our goal is to build not only the finest equipment and components,
but also to build long-term customer relationships founded on
superb quality, service, value and trust.
Randall Richardson, President
Specifications
Input voltage: Selectable
100/120/220 VAC 50/60Hz 26/20 VA
Internal voltage: 24 VDC
Foot pedal voltage: 9 VDC
Air input: 80 to 100 psi (5.5 to 6.9 bar)
Air output: (900)
0 to 100 psi (0 to 6.9 bar)
Air output: (900-15, 900-CA)
0 to 15 psi (0 to 1.0 bar)
Cycle rate: >600/minute
Time repeat: ±0.1%
Time ranges: programmable (seconds)
0.005 to 0.04 sec.
0.01 to 1.0 sec.
0.1 to 10 sec.
0.2 to 20 sec.
0.3 to 31 sec.
900, 900-15, 900-CA
8⅝x 8½x 2⅝"4 lb 2 oz
(21.9 x 21.6 x 6.7 cm) (1.87 kg)

First: Unpackandusethechecklistenclosedwith
the Dispenser Kit to identify all items. If there is
any discrepancy, please call us immediately.
Second: Powerandcompressedplantairshould
be available where the dispenser is to be set up.
Air pressure should be between 80 and 100 psi
(5.5and6.9bar). IfyouarenotusinganEFDfive-
micron filter regulator #2000F755, be certain
yo r plant air is properly filtered and dry and
a reg lated, constant air press re is s pplied
to the dispenser.
Note: Model900-CAissuppliedwithanEFD five-
micron filter regulator with coalescing filter
(#2000F756).
Bottled nitrogen can be used.
Warning: If high pressure bottled air or nitrogen is
used,ahigh pressure regulator must be installed
on the bottle and set at 100 psi maximum. The
2000F755 filter regulator is not recommended.
Checkthevoltagelabeltobecertainitissettothe
available power.
Third: Now is a good time to ACTIVATE your
extendedTwo Year Limited Warranty. Please fill
inandreturn thepostagepaidWarrantycard. Or
ifyouprefer, call the appropriate toll-free number
listed below, provide the serial number of your
dispenser and respond to a few short questions.
You are then assured of complete protection for
two years.
In the US, call 800-556-3484.
In Mexico, call 001-800-556-3484.
In the UK, ring free 0800 585733. 3
Contents
Hookup .................................................... 4-5
Setup for Testing...................................... 6-7
Testing the Dispensers ............................ 8-9
Programmable Timer .................................. 9
How to Use the Vacuum Control.......... 10-11
ULTRA Dispensing System.................. 12-13
Loading the Barrel Reservoirs.............. 14-15
Schematic & Parts..................................... 16
Troubleshooting ........................................ 17
Suggestions & Reminders......................... 18
Reordering Components ........................... 19
Two Year Limited Warranty....................... 20
Meets applicable CSA and CE requirements.
Reference CSA LR File Number 84105
First Steps
ThismanualisfortheexpressandsoleuseofEFDdispenserpurchasers
andusers,and no portionofthis manual maybereproduced in anyform.
EFD, ULTRA System, LV Barrier, SmoothFlow, ZeroDraft, SafetyLok,
SnapLokand DispenStand aretrademarks of EFD Inc. ©2002 EFD Inc. ☎
Making Timed Deposits of Medium to Thick Fluids
Changing Deposit Size and Drawing Stripes
Making Timed Deposits of Watery-thin Fluids

900
4
Plant air, 125 psi maximum to
regulator. Output from regulator
should be a minimum of 80 psi,
maximum 100 psi.
❶
❷
Check voltage label
on dispenser
❸
❼
Male quick-connect,
insert and twist to lock
Blue test
fluid
❹
❻
❺
Air input
hose
Power cord
Adapter
assembly
Foot pedal
assembly
Note: For hookup purposes,
connections for the 900,
900-15 and 900-CA models
are identical.

5
Hookup
❶Connect the air input hose to a plant air source. Set plant air
supplywithin80to100psi(5.5to6.9bar). Whererequired,use
an EFD five-micron filter regulator #2000F755 (see Warranty).
❷Attach the air input hose coupling to the dispenser. Pull back
metal ring to attach to dispenser.
❸Plug in the polarized foot pedal connector.
❹Check the voltage label on the input voltage selector cartridge.
To change the voltage, remove the voltage selector from the
cartridge, rotate it and position the correct voltage to show
through the cartridge window. Replace the cartridge into the
powercordreceptacleandinsurethatbothsidessnapsecurely
into position. Install the power cord.
Note: For 900-15 and 900-CA dispensers, use the test barrel filled
with clear fluid and the red 25 gage tip. Refer to “Making Timed
Deposits of Watery-thin Fluids” on page 10.
❺Attach the 10cc barrel pre-filled with blue, nontoxic test fluid
(included with the dispenser) to the 10cc adapter head.
❻Take the 10cc barrel adapter assembly (#5150 on the adapter
head) and insert the black, male quick-connect into the air
outputfittingonthefrontpanelandturnclockwisetolock. Place
the barrel in the barrel stand.
❼During the initial testing, you will not use the vacuum control.
Keepthiscontrol shutoff (turnedcompletelyclockwise—donot
force).
Spare Fuse
Voltage Value
220
120
100
Cartridge Window
(check voltage indicated)
Note: The dispenser is
shipped with the f se cartridge
set for 120 VAC inp t.

6
Note: The controls for the 900, 900-15 and 900-CA dispenser models are identical.
Controls & Connections
Foot pedal
receptacle
Barrel
vacuum control
Air output
quick-connect Timer bypass
Power
switch
Air pressure
regulatorAir gauge
Cycle LEDTime control
120
Voltage selector and
fuse cartridge
Air input
Vacuum transducer Power input
receptacle
❸❷
❹
❶❺
❻

7
Power switch ❶should be off.
The amount of material dispensed each cycle depends on the
combination of air pressure, time of air pulse, viscosity of material
and dispensing tip size.
Note: The following steps refer to the 900 dispenser. For the
900-15 and 900-CA dispensers, refer to “Making Timed Deposits of
Watery-thin Fluids” on page 10.
Thefirststepistoremovethetipcapfromthepre-filledbarrelofblue
test material (twist and pull). Replace it with an 18 gage (green)
tapered dispensing tip. Press the tip on and twist clockwise to lock.
Pullout air pressureregulatorknob ❷until it “clicks”intothe unlocked
position. Turnclockwisetoadjusttheairpressureto30psi(2.1bar)
for the initial tests .
Always set the pressure desired by turning the air regulator knob ❷
clockwise. Toreduce the pressure, turn the knob counterclockwise
untilthegauge❸ readsalowerpressurethandesired. Thenincrease
and stop at desired pressure. Push knob in to lock.
Set time control ❹to #7. Dispense cycle time increases from 0.01
second minimum to 1.0 second as knob is turned clockwise.
Besurevacuumcontrol❺isturnedoff(turnclockwise)forinitialtests.
Press power switch ❶to turn on the dispenser. It will light green.
Press timer bypass switch ❻. It will light yellow. In this operation
mode,the timer will be bypassedtofill the dispensing tip beforeyou
begintesting. Acontinuousflowofmaterialwilloccuraslongasthe
foot pedal is pressed.
Please continue to page 8 for test procedures.
Setup for Testing

Making Timed Deposits of Medium to Thick Fluids
(Model 900)
Youarenowreadytotestthepre-filled,nontoxic,bluetestfluid. This
material is representative of thick, non-leveling fluids like sealants,
pastes or greases.
Check your initial settings:
A) Air gauge reads 30 psi.
B) Timer is set at #7.
C) Green tapered tip is on the test barrel.
D) Power and timer bypass switches are on.
Holding the barrel as shown, rest the tip on a piece of paper. Press
the foot pedal until the tip fills and some fluid is pushed out onto the
paper. Repeat this whenever you change to a new tip.
With the tip filled, turn off the timer bypass switch (yellow light out).
Take the Dot Test sheet and put the tip on a 1/4" circle, holding the
barrel as shown. Press the foot pedal. Check the dot size. Make
several more similar dots and note the size consistency.
Remember–Whentheyellowtimerbypassswitchison,acontinuous
flow of material will occur as long as the foot pedal is pressed. The
yellow light must be off to make timed deposits.
8
Testing the Dispensers
Correct angle for consistent deposits.
Remember-alwaysbringthetipin
contact with the work surface at
theillustratedangle. Afterthetipis
in position, press the foot pedal.
Release pedal and remove tip by
lifting straight up.
Timer
Pressure
30
2
7
6
8

9
Blue Tip Settings
Test Pressure Time Dot Size
G 30 psi #6
H 20 psi #6
I 20 psi #3
J 15 psi #3
K 10 psi #3
O
N
1234
0.3-31 seconds
0.2-20 seconds
(4) ON = Maintained pedal contact (hold foot pedal down during time cycle)
(4) OFF = Momentary pedal contact (press foot pedal once)
Caution: Always disconnect the power cord before removing the cover.
O
N
1234
1234
O
N
O
N
1234
Changing Deposit Size, Drawing Stripes
Thedotsizeisdeterminedbythetipdiameter,theairpressureoutput setting
andthepulsetime. Forlargedots,usealargetip,higherpressureandmore
time. Normally, you want to use as short a time pulse as possible. To
increase the dot size, slightly increase output air pressure, or increase tip
size, or both.
Dot Test with Green Tapered Tip
First, follow the settings illustrated on the right, and you will get dots about
the size shown. Try other times and pressures to see how easy it is to get
just the dot size you want.
Dot Test with Blue Tapered Tip
These tests show the effect of using a smaller diameter tip.
Replace the green tip with the blue (22 gage) tapered tip. Now, turn on the
timer bypass switch and press the foot pedal to fill the tip. Then, turn off the
timer bypass switch (yellow light out) and press the foot pedal.
Tomakestripes,pressthetimer bypassswitch(yellow lighton). Withthe tip
in contact with the test sheet, press and hold down the foot pedal while
making a bead or stripe.
Programmable Timer
Each900seriesdispenserhasadigitaltimerwithprogrammabletimeranges.
The DIP switch that controls the timer has been set at the factory for a time
range of 0.01 to 1.0 second, with the initiation set to MOMENTARY contact.
Ifalongertimerangeisrequired,orfootpedaloperationneedstobechanged
from momentary to maintained, choose the appropriate dip switch setting in
the chart below.
Green Tip Settings
Test Pressure Time Dot Size
A 30 psi #7
B 20 psi #7
C 10 psi #7
D 20 psi #3
E 15 psi #3
F 10 psi #3
0.01-1.0 second 0.1-10 seconds
DIP Switch Settings

10
How to Use the Vacuum Control
Making Timed Deposits of Watery-thin Fluids
(Models 900, 900-15, 900-CA)
The vacuum control allows low viscosity fluids, even water, to be
consistentlydispensedwithoutdrippingbetweencycles. Thevacuum
exerts a negative pressure on the fluid in the barrel and prevents
dripping.
Forthesetests,youwillusethetestbarrelsuppliedwiththeclearfluid.
1. Whileholdingthebarreluprightinonehand,removetheorange
end cap ❶and insert the blue LV Barrier™❷. Allow an air gap
as shown.
2. Attach the barrel to the 10cc adapter ❸. Snap the safety clip
tightly closed to prevent any dripping or bubbling. Remove the
tip cap ❹and attach the 25 gage (red) tip.
3. Set air pressure at 5 psi.
4. Press the timer bypass switch (yellow light on).
5. Withthebarrelpointingdownwardoveracontainer,unsnapthe
safety clip. Then press the foot pedal to fill the tip.
6. Set the timer at #5. Press the timer bypass switch again
(yellow light out).
7. If a drop begins to form at the end of the tip, slowly turn the
vacuum control knob counterclockwise to stop the drop from
growing. Wipe the tip and adjust vacuum as necessary.
8. Takethebarrelandplacethetiponthetestsheet. Pressthefoot
pedalandrelease. Checkthedotsize. Increaseordecreaseby
adjusting pressure or time.
Insert LV
Barrier™
Remove
tip cap
Air gap
Remove
orange
end cap
❸
❶❷
❹
Attach
10cc adapter

11
☎
IMPORTANT
Regardless of the fluid viscosity, using the correct EFD piston will give you better results.
White SmoothFlow™piston for most fluids, blue LV Barrier™for watery-thin fluids and
orangeflatwall pistonforthick, stringyfluids.Seepages12 -13foracomplete description
of how EFD pistons work and the benefits they can bring to your operation.
Open
Closed
Ifyouchoosenottousethepiston,pleasefollowtheseinstructions
carefully:
1. Whileholdingthebarreluprightinonehand,twistonanorange
tipcap. Usingthesmallfunnel,fillabout2/3fullwithyourfluid.
2. Openthesafetyclipandattachthebarreltothe10ccadapter.
3. Close the safety clip as tight as possible.
4. Increase vacuum by turning vacuum control knob counter-
clockwise and set to 1.5 on the vacuum pressure gauge.
5. Then, without tipping the barrel upside down, remove the tip
cap and attach the 25 gage (red) tip.
6. Open the safety clip. Your material may begin to bubble.
Reduce vacuum by turning vacuum control knob clockwise.
7. If a drop begins to form at the end of the tip, slowly turn the
vacuumcontrol knob counterclockwise to stop the drop from
growing. Wipe the tip and adjust vacuum as necessary.
Now the fluid is in proper balance. It does not bubble or drip.
Repeat tests as before, keeping the air pressure low and adjust-
ing the time for different deposit sizes. Contact EFD if you have
any questions.
In the US, call 800-556-3484.
In Mexico, call 001-800-556-3484.
In the UK, ring free 0800 585733.
Do not tip the barrel upside down
or lay flat. This will cause the
liquid to run into the dispenser.
When changing tips
or attaching a tip cap,
snap the safety clip
completely closed to
prevent any dripping
or bubbling.
Three things to remember
If you do not use the piston
when dispensing thin fluids:
Use an EFD filter trap
(#1000FLT-Y). This
filter trap will impede
the flow should the
low viscosity liquid be
sucked back towards
the dispenser.

12
Advanced Dispensing System
If you dispense thick fluids, several problems may
occur. First, the repetitive air cycles can bore
tunnels through non-leveling fluids, causing spit-
tingandinconsistentdeposits. Second,thickfluids
contain trapped air that leads to drooling and
oozing.
These problems are eliminated by using the
SmoothFlow™piston. That's because the white
pistons prevent tunneling by providing a barrier to
the pulsed-air cycles, and prevent oozing by
responding to the pressure of trapped air with a
slight suck-back movement after the dispense
cycle.
The white piston is used for most fluids.
However,ifyouareapplyingRTVsiliconeandfind
that the piston bounces and causes stringing,
switch to the orange, flat wall piston.
TheSmoothFlow™pistonsmakebarrelfillingeasier,
too. As you load the fluid in, air is trapped in the
bottom and throughout the fluid. Simply insert a
SmoothFlow™pistonandgentlypressdownonthe
fluidasfaraspossible. Thisactionforcesoutmost
of the air and results in consistent deposits.
For Thick Fluids
Air Pressure
OFF
Air Pressure
ON
No drip
or ooze.
TM

Ifyouuselowtomediumviscosityfluids,thewhite
SmoothFlow™piston has several advantages.
First, vacuum adjustment is much less sensitive.
Second, the piston prevents fumes from the fluid
beingexhaustedintotheworkenvironment. Third,
the piston prevents fluid backflow into the dis-
penser if the barrel is inadvertently turned upside
down. Fourth,usingthepistonmakesiteasyand
safe to change tips without dripping.
Note: Ifyouusewatery-thinfluidssuchassolvents,
cyanoacrylatesandanaerobics,specifytheULTRA
System™with the blue LV Barrier™
. Available in
3cc and 10cc sizes.
13
Fumes cannot escape.
For Thinner Fluids
SmoothFlow™piston
prevents fluid backflow.
No air gap when using the
SmoothFlow™piston.
For Cyanoacrylates
or Watery-thin Fluids
Blue LV Barrier™for improved
control of very low viscosity fluids.
Note: The LV Barrier ™works best
with an air gap between the barrier
and fluid.
Maximum
1/2 fill
Note: If you choose not to use a piston,
please refer to page 11 for instructions.

14
Caution: Do not completely fill barrels. The optimum fill is a max-
imum 2/3 of the barrel capacity and 1/2 of the barrel capacity when
using the LV Barrier™.
If the fluid you are dispensing is pourable, take the barrel, twist on
atipcapandpouryourfluidin. Ifappropriate,inserttheSmoothFlow™
piston (see page 13). Carefully press the piston down until it
contacts the fluid. The barrel is now ready for use.
If you are dispensing solvents, cyanoacrylates or anaerobics, use
theLVBarrier™
. Placebarrierinthetopofthebarrelreservoir. Allow
airbetweenbarrierand fluid. Do not contact the barrier to the fluid.
If your fluid is thick or non-leveling, you can spoon it into the barrel
with a spatula Or, if the fluid comes packed in a 1/10 gallon
cartridge, try loading the barrel with a caulking gun. Then press in
theSmoothFlow™pistontomovethefluidtothebottomofthebarrel
and to remove trapped air.
Loading the Barrel Reservoirs
2/3
maximum
fill
2/3
maximum
fill
Fill procedure for thick fluids
(shown: caulking gun)
Fill procedure for cyanoacrylates
or watery-thin fluids
LV Barrier™
Air gap
1/2 maximum fill
Fill procedure for
pourable fluids
White
SmoothFlow™
piston

15
EFDoffersproductivealternativestotraditionalbarrelloadingmeth-
ods. Hereare a few suggestions that can help keep your work area
clean,savetime andreducethechanceof entrappedairinthefluid.
1. YoucouldusetheEFD#920BLbarrelloader. Packthefluidinto
the 12 ounce cartridge as shown. Then place the pre-filled
cartridge into the barrel loader. Using air pressure, the barrel
loader fills the barrel (with piston) from the bottom up.
Ifthefluidcomespackedina1/10gallon(300ml.)caulkingtype
cartridge, use the EFD #940BL barrel loader.
2. If you receive frozen epoxies or other fluids in medical type
syringes with a manual plunger, ask your fluid packager to use
EFD industrial grade barrels, or request our luer-to-luer fitting
#2160 to transfer the material.
Please call an EFD Product Specialist for additional assistance.
#2160 Luer-to-luer fitting
Filling the cartridge
for the barrel loader.
2/3
Maximum
Fill
EFD #920BL Barrel Loader
(Specify #940BL for prefilled 1/10 gallon caulking tubes)
Barrel Rack
#905BR holds (72) 3cc and 5cc barrels
#910BR holds (24) 10cc, 30cc and 55cc barrels

16
Replacement Parts List
1. 1000INP-AKIT* Air input hose-mini coupler
2. 2-2002A-XL Regulator assembly 0 to 15 psi
2-2002-XL Regulator assembly 0 to 100 psi
3. 2-2003-1000 24 VDC solenoid assembly
4. 2-2004B Quick-connect assembly
5. 2-2007-XL Potentiometer assembly
6. 2-2011-24 Timer bypass switch assembly
7. 7111E Fuse .160A
8. 2-2017A-24XL Foot-pedal receptacle
9. 2-2031-1000 Transformer assembly multi input
10. 2-2170LV Vacuum transducer assembly
11. 2-2176-800 Barrel vacuum control
12. 2001B Gauge 0 to 15 psi, 0 to 1.0 bar
2001C Gauge 0 to 100 psi, 0 to 7.0 bar
13. 2002SCR* Replacement screen
for regulator
14. 2-2006-24PR Programmable timer
15. 2008A Time control knob with numbers
16. 2009-A24* Input cord, detachable
2009-G24* European cord, detachable
17. 2010-A24 Power switch 115 VAC
18. 2015A* Foot pedal assembly
19. 2019G Grey dispenser end panel
20. 2032 Fitting 1/8 NPTM x 1/4 barb, brass
21. 2-2033* Dispense indicator LED
22. 2037 Tubing .170 x 1/4" OD rigid - PE
23. 2081A Male mini air coupler-panel mount
24. 2084* Air restrictor
25. 2087 Fitting 1/8 NPTM x 1/4 barb elbow brass
26. 2088 Fitting 1/8 NPTF x 1/4 barb elbow brass
27. 2089 Fitting 1/8 NPTM x 1/4 barb tee brass
28. 2169 Fitting 1/8 NPTM x 1/8 FPT elbow
29. 2178 Fitting 1/8 NPTM x 1/4 barb elbow brass
30. 2086 Fitting 1/8 NPTM x 1/4 barb 90 brass
* Not Shown
Schematic & Parts
Input air
Regulated air
Vacuum
15
17 11
23
9
12 26
4
19
25
3030 3
10
7
8
26 29 28
5
20
24
22
14
27

17
NO POWER
Troubleshooting
POWER, BUT NO LIGHT
POWER, LIGHT, BUT
MACHINE DOES NOT OPERATE
INCONSISTENT DOTS
MATERIAL SUCK-BACK
1. Check voltage at wall outlet.
2. Check fuse. Order replacement fuse #7111E.
3. Unplugfromwall,removetopcover,visuallyinspectforanyloose
or shorted connections.
Switch module must be replaced.
1. Unplug power input cord.
2. Check foot pedal connection, foot pedal and internal switch.
1. Check dispensing tip, barrel and material for possible clogging.
2. Check air gauge to be sure air pressure is not varying.
3. Check to see if there are air bubbles in the material being
dispensed.
1. Use SmoothFlow™pistons or LV Barriers™to prevent this. (See
pages 12-13.)
2. If it occurs, attach an empty barrel, (put timer bypass switch on),
put barrel in a cup and press the pedal to expel the sucked-back
fluid.
3. Ifproblemcannotbecorrected,contactanEFDProductSpecialist
for assistance. Dispensers can be returned to EFD for repair.
1. Check to be sure timer bypass switch is off (yellow light out).
2. Check DIP switch positions (see page 9).
Note: TheEFD timer is very reliable. Mostquestions about the timer
are resolved by simply turning the timer bypass switch off (yellow
light out).
TIMER SEEMS INOPERATIVE

Suggestions & Reminders
#7300A
Barrel Stand
18
1. AlwaysuseanEFDpistontomakeyourbarrelloading,dispens-
ing and handling cleaner, safer and more accurate.
Caution: If you dispense watery-thin fluids and choose not to use
SmoothFlow™pistons –do not increase vacuum pressure rapidly
and do not tip the barrel. Vacuum may pull liquid into the air hose;
or when tipped, liquid may flow back into the dispenser.
2. Alwaysusenew barrelsand tips. Carefullydisposeofafteruse.
This procedure ensures maximum cleanliness, prevents con-
tamination and provides proper safety.
3. Do not completely fill the barrel. For most fluids, optimum fill is
a maximum 2/3 of the barrel capacity. For cyanoacrylates or
watery-thin fluids, optimum fill is 1/2 of the barrel capacity.
4. Use the EFD #DS1200 DispenStand™(supplied with model
900-CA) to help organize bench space. Adapter hose support
keeps hose off of the work area. See illustration.
5. Depending on the type of work you are doing, it may be easier
tobring the work to thebarrel. Mountthe barrel on a standsuch
as the EFD #7300A.
6. To ensure smooth fluid flow and to make
consistent deposits, always have the tip at
about a 45°angle to the work surface.
#DS1200
DispenStand™

General purpose precision tips
All EFD dispensing tips incorporate the unique
SafetyLok™color-coded polypropylene hubs.
Convenientlypackaged(50)tipspersee-through
boxforeasypartidentification.
gage ID 1/2" length hub color
14 .061" 5114-B olive
15 .054" 5115-B amber
18 .033" 5118-B green
20 .024" 5120-B pink
21 .020" 5121-B purple
22 .016" 5122-B blue
23 .013" 5123-B orange
25 .010" 5125-B red
27 .008" 5127-B clear
30 .006" 5130-B lavender
Useful accessories
#2000F755: Five micron filter
regulator provides proper air
filteringforalldispensers.
Orderifyoudonothavedry,
clean,filteredfactoryairsupply.
#2000F756: Five micron filter
regulatorwithcoalescingfilter.
Removes liquid aerosols from
air supply for cyanoacrylate
applications. (Supplied with
the 900-CA dispenser.)
#7300A: Barrel stand, fully
adjustable three axes.
#DS1400: DispenStand™
holdsdispenser
vertically.
#DS1200: Horizontal
stand tiltsdispenserat
a14°angleforconvenient
viewingandoperation. 19
Barrel adapter assemblies
Molded one-piece, yellow, SnapLok™adapter head
with Buna N O-ring, flexible 5/32" O.D. hose, male
quick-connect and safety clip.
size with 3-ft hose with 6-ft hose
3cc 1000Y5148 1000Y5148-6
5cc 1000Y5149 1000Y5149-6
10cc 1000Y5150 1000Y5150-6
30cc/55cc 1000Y5152 1000Y5152-6
Each box contains the same quantity of barrels
and pistons.
Thin to thick fluids (white SmoothFlow™piston).
UV-block opaque sets/
size clear amber black box
3cc 5109CP-B 5109AP-B 5109UP-B 50
5cc 5110CP-B 5110AP-B 5110UP-B 40
10cc 5111CP-B 5111AP-B 5111UP-B 30
30cc 5112CP-B 5112AP-B 5112UP-B 20
55cc 5113CP-B 5113AP-B n/a 15
Cyanoacrylates/watery-thin fluids (blue LV Barrier™)
clear barrel,
size LV Barrier™& tip cap sets/box
3cc 5109LV-B 50
10cc 5111LV-B 30
Smooth-flow tapered tips
Molded polyethylene with UV block. Packaged (50)
tips per see-through box for easy part identification.
gage ID tapered color
14 .063" 5114TT-B olive
16 .047" 5116TT-B grey
18 .033" 5118TT-B green
20 .023" 5120TT-B pink
22 .016" 5122TT-B blue
25 .010" 5125TT-B red
For complete selection and technical details, please refer to EFD Catalog and price list.
ULTRA System™Dispensing Components
DS1400
2000F755
2000F756
7300A

EFD Two Year Limited Warranty
All components of EFD dispensers are warranted to the original end user
for two years from date of purchase.
Withinthe period of thiswarranty, EFD will repairor replace free ofcharge
any defective component on return of the part, or the complete dispenser,
prepaid to the factory.
Inno eventshallany liabilityorobligationof EFDarisingfrom thiswarranty
exceed the purchase price of the equipment. Before using, user shall
determine the suitability of the product for his intended use, and user
assumes all risk and liability whatsoever in connection therewith. This
warranty is valid only when clean, dry, filtered air is used.
EFD makes no warranty whatsoever of merchantability or fitness for
a partic lar p rpose. In no event shall EFD be liable for incidental or
conseq ential damages.
©2002 EFD Inc. 900-MAN EFDInternationalInc.is incorporated with limited liabilityintheU.S.A.
Sales and service of EFD dispensers and
dispensing components is available
throughEFDauthorizeddistributorsinover
30 countries. Please contact EFD U.S.A.
for specific names and addresses.
Unit 14, Apex Business Centre, Boscombe Road
Dunstable, Bedfordshire LU5 4SB UK
Telephone: 01582 666334 Fax: 01582 664227
Freephone: 0800 585733 From Ireland: 00800 8272 9444
E-mail: [email protected]
Headquarters: 977 Waterman Avenue, East Providence, RI 02914-1378 USA
US: 800-556-3484 Mexico: 001-800-556-3484
Fax: 401-431-0237 Telephone: 401-434-1680
E-mail: [email protected] www.efd-inc.com
Printed on
recycled pape
r
®
A NORDSON COMPANY
This manual suits for next models
2
Table of contents
Other EFD Dispenser manuals
Popular Dispenser manuals by other brands

FCI
FCI MagicRound ASD-0001 installation manual

Fast Mover
Fast Mover FMT4300 instruction manual

The Splash Lab
The Splash Lab TSL.R.010 Series Installation & maintenance

Franke
Franke RODX619 Installation and operating instructions

Georgia Pacific
Georgia Pacific ActiveAire 56764 reference guide

Metcal
Metcal DX-250 user guide