EFD 800 User manual

Operating Guide
Model 800 Dispenser
®
A NORDSON COMPANY
US: 800-556-3484 In the UK: 0800 585733 In Mexico: 001-800-556-3484

☎
Introduction
Model800fluiddispenserprovidesyearsoftrouble-free,productive
service. ThisOperatingGuidewillhelpyoumaximizetheusefulness
of your new dispenser.
Pleasespendafewminutestobecomefamiliarwiththecontrolsand
features of your new dispenser. Follow our recommended testing
procedures. Reviewthehelpfulinformationwehaveincludedbased
on over 30 years of industrial dispensing experience.
Mostquestions youwill haveare answeredin thisGuide. However,
ifyouneedassistance,pleasedonothesitatetocontactEFDoryour
authorized EFD distributor.
In the US, call 800-556-3484.
In Mexico, call 001-800-556-3484.
In the UK, ring free 0800 585733.
The EFD Pledge
We pledge that you will be completely satisfied with our products.
We endeavor to ensure that every EFD product is produced to our
no-compromise quality standards.
If you feel that you are not receiving all the support you require,
orifyouhaveanyquestionsorcomments, I invite you towriteorcall
me personally.
Our goal is to build not only the finest equipment and components,
butalsotobuild long-term customer relationships foundedonsuperb
quality, service, value and trust. Randall Richardson, President
Model 800 Specifications
Input voltage: Selectable
100/120/220 VAC 50/60Hz 26/20 VA
Air input: 80 to 100 psi (5.5 to 6.9 bar)
Internal voltage: 24 VAC
Foot pedal voltage: 24 VAC
800
7¼x 8½x 2⅝" 3 lb 4 oz
(18.4 x 21.6 x 6.7 cm) (1.48 kg)
Air output: 0 to 100 psi (0 to 7.0 bar)

First: Unpackandusethechecklistenclosedwith
the Dispenser Kit to identify all items. If there is
any discrepancy, please call us immediately.
Second: Powerandcompressedplantairshould
be available where the dispenser is to be set up.
Air pressure should be between 80 and 100 psi
(5.5and6.9bar). IfyouarenotusinganEFDfive-
micron filter regulator #2000F755, be certain
your plant air is properly filtered and dry.
Bottled nitrogen can be used.
Warning: Ifhighpressurebottledair or nitrogen is
used,a high pressure regulator must be installed
onthebottleandsetupat100psimaximum.The
#2000F755 filter regulator is not required.
Check the voltage label to be certain it is set to
the available power.
Third: Now is a good time to ACTIVATE your
extendedTwo Year Limited Warranty. Please fill
inandreturn thepostagepaidWarrantycard. Or
ifyou prefer, call the appropriate toll-free number
listed below, provide the serial number of your
dispenser and respond to a few short questions.
You are then assured of complete protection for
two years.
US, call 800-556-3484.
In Mexico, call 001-800-556-3484.
In the UK, ring free 0800 585733.
ThismanualisfortheexpressandsoleuseofEFDdispenserpurchasers
andusers, andno portionof thismanualmaybereproducedinany form.
EFD, ULTRA System, LV Barrier, SmoothFlow, ZeroDraft, SafetyLok,
SnapLokandDispenStand are trademarksofEFD Inc. ©2001 EFDInc.
Contents
Dispenser Hookup.................................... 4-5
Controls & Connections .............................. 6
Setup for Testing......................................... 7
Testing the Dispenser ................................. 8
Using the Vacuum Control .......................... 9
ULTRA Dispensing System.................. 10-11
Loading the Barrel Reservoirs.............. 12-13
Suggestions & Reminders......................... 14
Components Reorder................................ 15
Two Year Limited Warranty....................... 16
Meets applicable CSA and CE requirements.
Reference CSA LR File Number 84105
First Steps
☎

800
Plant air, 125 psi maximum to
regulator. Output from regulator
should be a minimum of 80 psi,
maximum 100 psi.
❶
❷
Check voltage label
on dispenser
❸
❼
Male quick-connect,
insert and twist to lock
❹
❻
❺
Air input
hose
Power cord
Adapter
assembly
Foot pedal
assembly
Blue test
fluid

Dispenser Hookup
❶Connect the air input hose to a plant air source.
Setplantairsupplywithin80to100psi(5.5to6.9
bar). Where required, use an EFD five-micron
filter regulator #2000F755 (see Warranty).
❷Attachtheairinputhosecouplingtothedispenser.
Pull back metal ring to attach to dispenser.
❸Plug in the polarized, foot pedal connector.
❹Check the voltage label on the input voltage
selector cartridge. To change the voltage,
remove the voltage selector from the cartridge,
rotate it and position the correct voltage to show
through the cartridge window. Replace the
cartridge into the power cord receptacle and
insurethatbothsidessnapsecurelyintoposition.
Install the power cord.
Spare Fuse
Cartridge Window
(check voltage indicated)
Voltage Value
❺Attach the 10cc barrel prefilled with blue,
nontoxic test fluid (included with the
dispenser) to the 10cc adapter head.
❻Take the 10cc barrel adapter assembly
(#5150 on the adapter head) and insert the
black,malequick-connectintotheairoutput
fitting on the front panel and turn clockwise
to lock. Place the barrel in the barrel stand.
❼Duringtheinitialtesting, you will notusethe
vacuum control. Keep this control shutoff
(turnedcompletelyclockwise—donotforce).
220
120
100
Note: The dispenser is shipped with the fuse
cartridge set for 120 VAC input.

Controls & Connections
❹
Foot pedal
receptacle
Air input Power input
receptacle
Vacuum
transducer Voltage selector and
fuse cartridge
Barrel
vacuum control
Air output
quick-connect
Power
switch
❸❷
Air pressure
regulator
❶
Air gauge
120

Power switch ❶ should be off.
The amount of material dispensed each cycle depends on the
combinationofairpressure,viscosityofmaterial,dispensingtipsize
and the length of time the foot pedal is pressed.
Thefirststepis toremovethetipcapfromthe prefilledbarrelofblue
test material (twist and pull). Replace it with an 18 gage (green)
tapered dispensing tip. Press the tip on and twist clockwise to lock.
Pull out air pressure regulator knob ❷until it "clicks" into the
unlockedposition. Turnclockwisetoadjusttheairpressureto10psi
(0.7 bar) for the initial tests.
Always set the pressure desired by turning the air regulator knob
❷clockwise. To reduce the pressure, turn the knob counterclock-
wiseuntiltheairgauge❸readsalowerpressurethandesired.Then
increase and stop at desired pressure. Push knob in to lock.
Be sure barrel vacuum control ❹is turned off (turn clockwise) for
initial tests.
Press power switch ❶to turn on the dispenser. It will light green.
Please continue to page 8 for test procedures.
model 800
Setup for Testing

You are now ready to test the dispenser using the prefilled barrel
of blue, nontoxic test material.
Begin with the following settings:
Thick fluid (blue) Thin fluid (clear)
Air gauge 10 psi (0.7 bar) 5 psi (0.4 bar)
Dispense tip 18 gage (green) 25 gage (red)
Vacuum control Off On (see page 9)
Press the power switch on. It will light green.
Holding the barrel as shown, rest the tip on a piece of paper. Press
the foot pedal until the tip fills and some fluid is pushed out onto the
paper. (Repeat this whenever you change to a new tip.)
Use the Dot Test Sheet supplied, and press the foot pedal to make
a dot or stripe. Make several more deposits, carefully applying the
tip at the angle shown and removing the tip as shown.
Remember - always bring the tip in contact with the work surface at
theillustratedangle. Afterthe tip is inposition,pressthefoot pedal.
A continuous flow of material will occur as long as the foot pedal is
pressed.
Trydifferentpressuresettings. Continuetoexperimentbyreplacing
the green tip with the blue (22 gage) tapered tip included in the Dot
TestKit. Notethe effects of airpressureand tip sizeonthe deposit.
Adjusting the Deposit Amount
The deposit size is determined by the tip diameter, the output air
pressure setting and the length of time the foot pedal is pressed.
Toincreasethedepositsize,slightlyincreaseoutputairpressure,or
increase tip size, or both. To decrease the deposit amount, use a
smaller tip size, or lower the air pressure.
Testing the Dispenser
Correct angle for making deposits.
Remember-alwaysbringthetipin
contact with the work surface at
theillustratedangle. Afterthetipis
in position, press the foot pedal.
Release pedal and remove tip by
lifting straight up.

Using the Vacuum Control
The vacuum control allows low viscosity fluids,
even water, to be consistently dispensed without
dripping between cycles. The vacuum exerts a
negative pressure on the fluid in the barrel and
prevents dripping.
Forthesetests,youwillusethetestbarrelwiththe
clear fluid.
1. While holding the barrel upright in one hand,
remove the orange end cap and insert the
white SmoothFlow™piston. Carefully press
the piston down until it contacts the fluid.
Besuretopushitfarenoughtoremoveallair,
but not into the fluid, since this will force the
fluid up along the sides of the piston.
2. Attach the barrel to the yellow adapter head.
Snap the safety clip tightly closed to prevent
anydrippingorbubbling. Remove thetipcap
and attach the 25 gage (red) tip.
3. Set air pressure at 5 psi (0.4 bar).
4. With the barrel pointing downward over a
container, press the foot pedal to fill the tip.
Remove
tip cap
Insert
SmoothFlow™
piston
Remove
orange
end cap
5. If a drop begins to form at the end of the tip,
slowlyturn the vacuum control knob counter-
clockwise to stop the drop from growing.
Wipe the tip and slowly adjust vacuum as
necessary.
6. Take the barrel and place the tip on the Dot
TestSheet. Pressthefootpedalandrelease.
Check the deposit. You control the fluid flow
Regardless of the viscosity of the fluid you use,
youshouldtryusingtheSmoothFlow™piston(see
pages 10-11).
Ifyouchoosenottousethepiston,pleasereadthe
following points. rate by increasing the air pres-
sure output (higher flow) or decreasing the air
pressure output.
Do not tip the barrel
upside down or lay flat.
This will cause the fluid
to run into the dispenser.
When changing tips or attaching
a tip cap, snap the safety clip
completely closed to prevent any
dripping or bubbling.
Three things to remember
If you do not use the piston
when dispensing thin fluids:
Use an EFD filter trap
(#1000FLT-Y). This filter trap
will impede the flow should the
low viscosity fluid be sucked
back towards the dispenser.
Open
Closed

Advanced Dispensing System
TM
If you dispense thick fluids, several problems may
occur. First,therepetitiveaircyclescanboretunnels
through non-leveling fluids, causing spitting and
inconsistent deposits. Second, thick fluids contain
trapped air that leads to drooling and oozing.
TheseproblemsareeliminatedbyusingtheSmoothFlow™
piston. That's because the white pistons prevent
tunneling by providing a barrier to the pulsed-air
cycles, and prevent oozing by responding to the
pressure of trapped air with a slight suck-back
movement after the dispense cycle.
The white piston is used for most fluids.
However, if you are applying RTV silicone and find
thatthepistonbouncesandcausesstringing,switch
to the orange, flat wall piston.
TheSmoothFlow™pistonsmakebarrelfillingeasier,
too. As you load the fluid in, air is trapped in the
bottom and throughout the fluid. Simply insert a
SmoothFlow™piston and gently press down on the
fluid as far as possible. This action forces out most
of the air and results in consistent deposits.
For Thick Fluids
Air Pressure
OFF
Air Pressure
ON
No drip
or ooze.

Ifyouuselowtomediumviscosityfluids,thewhite
SmoothFlow™piston has several advantages.
First, vacuum adjustment is much less sensitive.
Second, the piston prevents fumes from the fluid
beingexhaustedintotheworkenvironment. Third,
the piston prevents fluid backflow into the dis-
penser if the barrel is inadvertently turned upside
down. Fourth,usingthepiston makesiteasyand
safe to change tips without dripping.
Note: Ifyouusewatery-thinfluidssuchassolvents,
cyanoacrylatesandanaerobics,specifytheULTRA
System™with the blue LV Barrier™
. Available in
3cc and 10cc sizes.
For Thinner Fluids
Fumes cannot escape.
For Cyanoacrylates
or Watery-thin Fluids
SmoothFlow™piston
prevents fluid backflow.
No air gap when using the
SmoothFlow™piston.
Note:
If you choose not to use the piston,
please refer to page 9 for instructions.
Blue LV Barrier
™
for improved
control of very low viscosity fluids.
Note: The LV Barrier
™
works best
with an air gap between the barrier
and fluid.
Maximum
1/2 fill

Caution: Do not completely fill barrels. The optimum fill is a maxi-
mum 2/3 of the barrel capacity and 1/2 of the barrel capacity when
using the LV Barrier™.
If the fluid you are dispensing is pourable, take the barrel, twist on
atipcapandpouryourfluidin. Ifappropriate,inserttheSmoothFlow™
piston (see pages 10-11). Carefully press the piston down until it
contacts the fluid. The barrel is now ready for use.
Ifyouaredispensingwaterysolvents,cyanoacrylatesoranaerobics,
use the LV Barrier™
. Place barrier in the top of the barrel reservoir.
Allowair between barrierand fluid. Donot contact thebarrier to the
fluid.
If your fluid is thick or non-leveling, you can spoon it into the barrel
withaspatula Or,ifthefluidcomespackedina1/10galloncartridge,
try loading the barrel with a caulking gun. Then press in the
SmoothFlow™pistontomovethefluidtothebottomofthebarreland
to remove trapped air.
Loading the Barrel Reservoirs
Fill procedure for
pourable fluids
White
SmoothFlow™
piston
Fill procedure for thick fluids
(shown: caulking gun)
2/3
maximum
fill Fill procedure for cyanoacrylates
or watery-thin fluids
LV Barrier™
Air gap
1/2 maximum fill
2/3
maximum
fill

EFDoffersproductivealternativestotraditionalbarrel-loadingmeth-
ods. Hereare a few suggestions that can helpkeep your work area
clean,savetimeandreducethechanceofentrappedairin the fluid.
1. YoucouldusetheEFD#920BLbarrelloader. Packthefluidinto
the 12 ounce cartridge as shown. Then place the pre-filled
cartridge into the barrel loader. Using air pressure, the barrel
loader fills the barrel (with piston) from the bottom up.
Ifthefluidcomespackedina1/10gallon(300ml.)caulkingtype
cartridge, use the EFD #940BL barrel loader.
2. If you receive frozen epoxies or other fluids in medical type
syringes with a manual plunger, ask your fluid packager to use
EFD industrial grade barrels, or request our luer-to-luer fitting
#2160 to transfer the material.
Please call an EFD Fluid Application Specialist
for additional assistance.
Filling the cartridge
for the barrel loader.
2/3
Maximum
Fill
EFD #920BL Barrel Loader
(Specify #940BL for pre-filled 1/10 gallon caulking tubes)
Barrel Rack
#905BR holds (72) 3cc and 5cc barrels
#910BR holds (24) 10cc, 30cc and 55cc barrels
#2160 Luer-to-luer fitting

Suggestions & Reminders
1. Always use an EFD piston to make your barrel loading,
dispensing and handling cleaner, safer and more accurate.
Caution: Ifyoudispensewatery-thinfluidsandchoosenottouse
SmoothFlow™pistons –do not increase vacuum pressure
rapidlyanddonottipthebarrel. Vacuummaypullliquidintothe
airhose;orwhentipped,liquidmayflowbackintothedispenser.
2. Always use new barrels and tips. Carefully dispose of after
use. This procedure ensures maximum cleanliness, pre-
vents contamination and provides proper safety.
3. Donotcompletelyfillthebarrel. Formostfluids,optimumfill
isamaximum2/3ofthebarrelcapacity.Forcyanoacrylates
orwatery-thinfluids,optimumfillis1/2ofthebarrelcapacity.
4. Use the EFD #DS1200 DispenStand™to help organize
bench space. Adapter hose support keeps hose off of the
work area. See illustration.
5. Depending on the type of work you are doing, it may be
easier to bring the work to the barrel. Mount the barrel on a
stand such as the EFD #7300A.
6. To ensure smooth fluid flow and to make consistent depos-
its, always have the tip at about a 45°angle to the work
surface.
#7300A
Barrel Stand
#DS1200
DispenStand™

General purpose precision tips
All EFD dispensing tips incorporate the unique
SafetyLok™color-coded polypropylene hubs.
Convenientlypackaged(50)tipspersee-through
box for easy part identification.
gage ID 1/2" length hub color
14 .061" 5114-B olive
15 .054" 5115-B amber
18 .033" 5118-B green
20 .024" 5120-B pink
21 .020" 5121-B purple
22 .016" 5122-B blue
23 .013" 5123-B orange
25 .010" 5125-B red
27 .008" 5127-B clear
30 .006" 5130-B lavender
Useful accessories
#2000F755: Five micron filter
regulator provides proper air
filtering for all dispensers.
Order if you do not have dry,
clean, filtered factory air supply.
#7300A: Barrel stand, fully
adjustable three axes.
#DS1200: Horizontal
stand tilts dispenser at
a 14°angle for convenient
viewing and operation.
#DS1400: DispenStand™
holds dispenser
vertically.
Barrel adapter assemblies
Molded one-piece, yellow, SnapLok™adapter head
with Buna N O-ring, flexible 5/32" O.D. hose, male
quick-connect and safety clip.
size with 3-ft hose with 6-ft hose
3cc 1000Y5148 1000Y5148-6
5cc 1000Y5149 1000Y5149-6
10cc 1000Y5150 1000Y5150-6
30cc/55cc 1000Y5152 1000Y5152-6
Each box contains the same quantity of barrels
and pistons. UV-block opaque sets/
size clear amber black box
3cc 5109CP-B 5109AP-B 5109UP-B 50
5cc 5110CP-B 5110AP-B 5110UP-B 40
10cc 5111CP-B 5111AP-B 5111UP-B 30
30cc 5112CP-B 5112AP-B 5112UP-B 20
55cc 5113CP-B 5113AP-B n/a 15
Smooth-flow tapered tips
Molded polyethylene with UV block. Packaged (50)
tips per see-through box for easy part identification.
gage ID tapered color
14 .063" 5114TT-B olive
16 .047" 5116TT-B grey
18 .033" 5118TT-B green
20 .023" 5120TT-B pink
22 .016" 5122TT-B blue
25 .010" 5125TT-B red
For complete selection and technical details, please refer to EFD Catalog and price list.
ULTRA System™Dispensing Components
2000F755
7300A
DS1400

EFD Two Year Limited Warranty
All components of EFD dispensers are warranted to the original end user
for two years from date of purchase.
Withinthe period of thiswarranty, EFDwill repairor replacefree ofcharge
any defective component on return of the part, or the complete dispenser,
prepaid to the factory.
Inno eventshallany liabilityorobligation ofEFDarisingfromthiswarranty
exceed the purchase price of the equipment. Before using, user shall
determine the suitability of the product for his intended use, and user
assumes all risk and liability whatsoever in connection therewith. This
warranty is valid only when clean, dry, filtered air is used.
EFD makes no warranty whatsoever of merchantability or fitness for
a particular purpose. In no event shall EFD be liable for incidental or
consequential damages.
©2001 EFD Inc. 800-MAN EFDInternationalInc.isincorporatedwith limited liability in the U.S.A.
Sales and service of EFD dispensers and
dispensing components is available
throughEFDauthorizeddistributorsinover
30 countries. Please contact EFD U.S.A.
for specific names and addresses.
Unit 14, Apex Business Centre, Boscombe Road
Dunstable, Bedfordshire LU5 4SB UK
Telephone: 01582 666334 Fax: 01582 664227
Freephone: 0800 585733 From Ireland: 00800 8272 9444
Headquarters: 977 Waterman Avenue, East Providence, RI 02914-1378 USA
US & Canada: 800-556-3484 Mexico: 001-800-556-3484
Telephone: 401-434-1680 Fax: 401- 431-0237
Printed on
recycled pape
r
®
A NORDSON COMPANY
EFD International Inc. is incorporated with limited liability in the U.S.A
Table of contents
Other EFD Dispenser manuals