1
Room temperature controller with hu-
midity and CO2equivalent regulator
Codes: EK-ET2-TP (for round and square wall box)
EK-ET2-TP-R (for rectangular wall box)
Main functional characteristics
The common features to all versions are documented as
follows:
• Temperature, relative humidity and air quality (CO2
equivalent) measuring through the integrated sensors,
with possibility of sending the read valued on the bus;
• Two-point (ON/OFF) or proportional (PWM or conti-
nuous) room temperature regulation;
• Seasonal modes: heating and cooling with possibility of
either local or via bus seasonal changeover;
• Operating modes: comfort, standby, economy and bu-
ilding protection with different setpoint for heating and
cooling functions;
• Automatic switching of the operating modes through
presence sensor or window contact;
• Weighted average of two temperature values;
• Dew-point temperature computation;
• Temperature regulation (measured and setpoint, as
°C), relative humidity (measured and setpoint in per-
centage), air quality (as CO2equivalent concentration,
in ppm), alarms and errors (with alphanumeric coding);
• Relative humidity thresholds setting;
• CO2equivalent thresholds setting;
• Floor temperature limitation and antincondensation (for
radiant panels);
• Delayed start of a fan (“hot-start”) with time-scheduling
or depending on the water temperature measured at
the coil for thermal exchange.
Other characteristics
• Plastic casing for wall mounting
• Integrated temperature, relative humidity and air quality
(CO2equivalent) sensors
• Protection degree IP20 (according to EN 60529)
• Classication climatic 3K5 and mechanical 3M2 (accor-
ding to EN 50491-2)
• Pollution degree 2 (according to IEC 60664-1)
Technical data
• Power supply 30 Vdc from KNX bus line
• Current consumption < 13 mA
• CO2output values: 400 ÷ 60000 ppm
Environmental conditions
• Operating temperature: −5 ... +45°C
• Storage temperature: −25 ... +55°C
• Transport temperature: −25 ... +70°C
• Relative humidity: 95% not condensing
Accessories
A metallic support, the xing screws and the terminal for
connection of the KNX bus line are delivered with the de-
vice. This has to be completed with the following items:
• a square rocker 60 x 60 mm, with set code EK-T1Q-...,
to be lled with the specic colour and material exten-
sion;
• a single plate and a frame, to be ordered separately,
except for the ‘NF (No Frame) version, which do not
require any frame.
Plate
The room temperature controller may be completed by a
square 1-fold plate or by a rectangular 2-fold plate. In both
cases the plate must be necessarily provided with a 60 x
60 mm window for the mounting of the device.
KNX thermostat with temperature, relative humidity and
CO2equivalent sensors, for the independent thermal re-
gulation of a room or a zone. It has to be used in KNX
installations for control of homes and buildings.
Description
The ekinex®EK-ET2-TP... room temperature controller
is a KNX S-mode device for the independent tempera-
ture regulation of a room or a zone in a building. It can
be installed in houses and buildings (e.g., ofces, hotels,
private house, etc.). The room temperature controller is
equipped with 3 sensors: temperature, relative humidity
and air quality (as CO2equivalent). It can also work as a
controller for these 3 parameters, that are available for a
single zone to be managed. Up to 8 LEDs can be con-
gured, in order to display the operating thresholds for the
CO2 equivalent, the activation of the humidication/dehu-
midication functionality and the cooling/heating working
modes. The device is equipped with an integrated KNX
bus communication module and is designed for wall in-
stallation on a ush mounting box. Both the programming
button and LED are located in the front of the device be-
low the rocker, as well as the 3 sensors. The device is
powered by the KNX bus line and does not require any
auxiliary power supply.
Note. The rocker and the frame (when necessary)
for the completion of the device must be ordered se-
parately. For more information on materials, colors
and nishes available, see also the ekinex®product
catalog or browse www.ekinex.com
i
Datasheet STEKEQ2TP_EN
TP1
S
REFLEKET2TP
REFLEKET2TPR

2
\
Frame
The room temperature controller can be completed by a
square 1-fold frame or by a rectangular 2-fold frame of the
ank or form series. The ‘NF (No Frame) versions of the
pushbutton do not require any frame.
Mounting
The device has degree of protection IP20, and is therefo-
re suitable for use in dry interior rooms. The installation of
the device requires the following steps:
Mounting with frame, round ush-mounting box
Carry out the following steps:
• x the metallic support (h) with the screws (g) on a
ush-mounting box (i) provided with suitable xing ho-
les;
• snap a square frame (f) of the form or ank series, in-
serting it from the rear of the preassembled thermostat-
adapter (d+e);
• insert the bus terminal, previously connected to the bus
cable, in its slot on the rear side (see also: “Connection
of the KNX bus line”). At this point it is recommended
to carry out the commissioning of the pushbutton (see
also “Conguration and commissioning”) or at least the
download of the physical address;
min 0,3 m
Mounting with rectangular ush-mounting box
Carry out the following steps:
• insert the metallic support (f) on the adapter (g);
• for versions provided with frame only: snap a rectangu-
lare frame (f) of either form or ank series, starting from
the back side of the support-adapter group (f+g) ;
• x adapter and metallic support (f+g) (and eventually
the frame, h) with the screws (e) on a ush-mounting
box (i) provided with suitable xing holes;
• insert the bus terminal, previously connected to the bus
cable, in its slot on the rear side (see also: “Connection
of the KNX bus line”). At this point it is recommended
to carry out the commissioning of the pushbutton (see
also “Conguration and commissioning”) or at least the
download of the physical address;
• insert the thermostat (d) in the support-adapter (f+g).
Mounting the device follow the indication TOP (arrow
tip pointing up) on the rear side of the device;
• tighten the device on the support-adapter (f+g) with the
• insert thermostat and adapter (d+e), completed with
the frame (f), in the metallic support (h). Mounting the
pushbutton follow the indication TOP (arrow tip pointing
up) on the rear side of the device;
• tighten thermostat, adapter and frame (d+e+f) on the
metallic support (h) with the two screws (c);
• snap the plate (a);
• snap the rocker (b) to complete the installation.
Mounting with no frame, round ush-mounting box
Carry out the following steps:
• insert the metallic support (f) on the adapter (g);
• x adapter and metallic support (f+g) with the screws
(e) on a ush-mounting box (h) provided with suitable
xing holes;
• insert the bus terminal, previously connected to the bus
cable, in its slot on the rear side (see also: “Connection
of the KNX bus line”). At this point it is recommended
to carry out the commissioning of the pushbutton (see
also “Conguration and commissioning”) or at least the
download of the physical address;
• insert the thermostat (d) in the support-adapter (f+g).
Mounting the device follow the indication TOP (arrow
tip pointing up) on the rear side of the device;
• tighten the device on the support-adapter (f+g) with the
two screws (c);
• snap the plate (a);
• snap the rocker (b) to complete the installation.
a) 1-fold plate (square, with 60 x 60 mm window)
b) Rocker
c) Screws (for device)
d) Device
e) Adapter (delivered preassembled on the device)
f) Frame (square, form or ank series)
g) Screws (for metallic support)
h) Metallic support
i) Flush-mounting box (not delivered by ekinex®)
b c d e
h
g
f
a
i
Mounting with frame
ESEKET2TP
a b cd e
hgf
Mounting with no frame
a) 1-fold plate (square, with 60 x 60 mm window)
b) Rocker
c) Screws (for device)
d) Device
e) Screws (for metallic support)
f) Metallic support
g) Adapter for ‘NF series (delivered with the device)
h) Flush-mounting box (not delivered by ekinex®)
ESEKET2TPNF
Plate
code *Type Appearance Window
modularity [mm]
EK-PQS-... 1-fold ** 60 x 60
EK-PRS-... 1-fold ** 60 x 60
EK-P2G-... 2-fold *** 55 x 55 (1)
60 x 60 (1)
EK-P2S-... 2-fold *** 60 x 60 (2)
(*) To be completed with the extension for colour, material and nishing
(**) For mounting without frame (‘NF) it requires the EK-TAQ adapter
(***) For mounting without frame (‘NF) it requires the EK-A71-... adapter

3
two screws (c);
• snap the plate (a);
• snap the rocker (b) to complete the installation.
• Red LED (8) for indication that the measured CO2equi-
valent exceeds threshold 3;
• Blue LED (9) for indication that the measured CO2 equi-
valent lies between threshold 2 and 3;
• Blue LED (10) for indication that the measured CO2
equivalent lies between threshold 1 and 2;
• Blue LED (11) for indication that the measured CO2
equivalent lies below threshold 1;
• Red LED (12) for indication of the active operating
mode (on = programming, off = normal operation).
For measuring purposes the device is provided with:
• a temperature sensor (not visible, positioned behind
the passage 15);
• a relative humidity sensor (14);
• a CO2equivalent air quality sensor (16).
1,50 m
Mounting position
For optimum regulation the device has to be preferably
installed on an internal wall at the height of 1.5 m and at
least 0.3 m far from doors. The device cannot be installed
close to heat sources such as radiators or domestic ap-
pliances or in positions subject to direct sunlight. If neces-
sary, for the regulation may be used a weighted average
between two values selected among the following ones:
value measured by the internal sensor, value measured
by a temperature sensor connected to a device input, va-
lue received via bus by another KNX device (e.g. from
ekinex pushbuttons).
Switching, display and measuring elements
The device is equipped with a programming LED, 8 di-
splaying LEDs with lightguides for feedback status and
3 sensors.
Switching elements
• Pushbutton (13) for switching between the normal and
programming operating mode.
Display elements
• White / red LED (4) for indication of the heating mode
functionality active / heating ON;
• White / blue LED (5) for indication of the cooling mode
functionality active / cooling ON;
• Blue LED (6) for indication of the dehumidication fun-
ctionality ON;
• Green LED (7) for indication of the humidication fun-
ctionality ON;
i
a) 1-fold plate (square, with 60 x 60 mm window)
b) Rocker
c) Screws (for device)
d) Device
e) Screws (for metallic support)
f) Metallic support
g) Plastic adapter
h) Rectangular frame (not for NF version)
i) Flush-mounting box (not delivered by ekinex®)
a b cd
e hgf
1) Terminal block for KNX bus line
2) Product label
3) Adapter
4) White (heating mode active) or red (heating ON) LED
5) White (cooling mode active) or blue (cooling ON) LED
6) Blue LED (dehumidication ON)
7) Green LED (humidication ON)
8) Red LED (CO2 equivalent concentration > threshold 3)
9) Blue LED (CO2 eq. concentration between threshold 2 and 3)
10) Blue LED
(CO2eq. concentration between threshold 1 and 2)
11) Blue LED (
CO2equivalent concentration < threshold 1
)
12) Programming LED
13) Programming pushbutton
14) Relative humidity sensor
15) Temperature sensor
16) CO
2
equivalent sensor
i
Note. Programming pushbutton and LED are ac-
cessible from the front side of the device. The de-
vice addressing may be easily carried out after the
assembly of the frame, removing the rockers. Once
the addressing has been done, the device congu-
ration can be later downloaded without pressing the
programming pushbutton.
9
15 16
10
11
2
1
6
7
4
5
14
13
12
8

4
Connection of the KNX bus line
The connection of the KNX bus line is made with the ter-
minal block (black/red) included in delivery and inserted
into the slot of the housing.
Characteristics of the KNX terminal block
• spring clamping of conductors
• 4 seats for conductors for each polarity
• terminal suitable for KNX bus cable with single-wire
conductors and diameter between 0.6 and 0.8 mm
• recommended wire stripping approx. 5 mm
• color codication: red = + (positive) bus conductor,
black = − (negative) bus conductor
Commissioning
For commissioning the device the following activities are
required:
• make the electrical connections as described above;
• turn on the bus power supply;
• switch the device operation to the programming mode
by pressing the programming pushbutton located on
the front side in the area for the mounting of the ro-
ckers. In this mode of operation, the programming LED
is turned on;
• download into the device the physical address and the
conguration with the ETS®program.
At the end of the download the operation of the device
automatically returns to normal mode; in this mode the
programming LED is turned off. Now the bus device is
programmed and ready for use.
Dimensions [mm]
Warning! In order to supply the KNX bus lines use
only KNX bus power supplies (e.g. ekinex EK-AB1-
TP or EK-AG1-TP). The use of other power supplies
can compromise the communication and damage
the devices connected to the bus.
!
Warning! The electrical connection of the device
can be carried out only by qualied personnel. The
incorrect installation may result in electric shock or
re. Before making the electrical connections, make
sure the power supply has been turned off.
!
Code Application program
(## = release)
Comm.
objects
(max nr.)
Group
addr.
(max nr.)
EK-ET2-TP
APEKET2TP##.knxprod
137 254
Note. The conguration and commissioning of KNX
devices require specialized skills. To acquire these
skills, you should attend the workshops at KNX cer-
tied training centers.
i
+-
Bus
KNX
ELEKET2TP
L13 9
21
43
H
DQEKET2TP
Thermostat for round ush-mounting box
Version Dimensions L x H [mm]
frame mounting 81 x 77
no-frame mounting 80 x 80
Version Dimensions L x H [mm]
frame mounting 122 x 77
no-frame mounting 121 x 80
L
H
12 9
21
43
DQEKET2TPR
Thermostat for rectangular ush-mounting box
Conguration and commissioning
Conguration and commissioning of the device require
the use of the ETS®(Engineering Tool Software) program
V4 or later releases. These activities must be carried out
according to the design of the building automation system
done by a qualied planner.
Conguration
For the conguration of the device parameters the corre-
sponding application program or the whole ekinex®pro-
duct database must be loaded in the ETS program. For
detailed information on conguration options, refer to the
application manual of the device available on the website
www.ekinex.com.

5
DQTASTI71
2,5
29,5
29
60
29
2,5
14,5
58
2,5
60
58
2,5
Rocker
94
80
8
86 8
86
Square frame of
Form
EK-FOQ-... series
Square frame of
Flank
EK-FLQ-...series
80
80
3
60
60
Square plate
EK-PQS-...
126
86
8
Rectangular frame
form
EK-FOR-... serie
8
80
135
Rectangular frame
ank
EK-FLR-... serie
121
80
3
60
60
Rectangular
plate
EK-PRS-...
13 11
24
13 11
24
EK-ET2-TP Thermostat for no-frame
mounting (‘NF series), completed with
rocker and plate EK-PQS-...
EK-ET2-TP Thermostat of either Form
or Flank series, completed with rocker
and plate EK-PQS-...
Marks
• KNX
• CE: the device complies with the Low Voltage Directive
(2014 / 35 / EU) and the Electromagnetic Compatibility
Directive (2014 / 30 / EU). Tests carried out according
to EN 50491-5-1:2010 and EN 50491-5-2:2010
Maintenance
The device is maintenance-free. To clean use a dry cloth.
It must be avoided the use of solvents or other aggressive
substances.

6
Documentation
This datasheet refers to the release A1.0 of the ekinex®
device EK-ET2-TP... is available for download at www.
ekinex.com as a PDF (Portable Data Format) le.
File name Device release Updating
STEKET2TP_EN.pdf A1.0 02 / 2018
Disposal
At the end of its useful life the product de-
scribed in this datasheet is classied as wa-
ste from electronic equipment in accordance
with the European Directive 2012 / 19 / EU
(WEEE recast), and cannot be disposed to-
gether with the municipal undifferentiated so-
lid waste
Warning! Incorrect disposal of this product may
cause serious damage to the environment and hu-
man health. Please be informed about the correct
disposal procedures for waste collecting and pro-
cessing provided by local authorities.
!
Warnings
• Installation, electrical connection, conguration and
commissioning of the device can only be carried out by
qualied personnel in compliance with the applicable
technical standards and laws of the respective countri-
es
• Opening the housing of the device causes the imme-
diate end of the warranty period
• In case of tampering, the compliance with the essential
requirements of the applicable directives, for which the
device has been certied, is no longer guaranteed
• ekinex® KNX defective devices must be returned to the
manufacturer at the following address: Ekinex®S.p.A.
Via Novara 37, I-28010 Vaprio d’Agogna (NO) Italy
Other information
• This datasheet is aimed at installers, system integra-
tors and planners
• For further information on the product, please contact
the ekinex®technical support at the e-mail address:
com
• Each ekinex®device has a unique serial number on
the label. The serial number can be used by installers
or system integrators for documentation purposes and
has to be added in each communication addressed to
the ekinex®technical support in case of malfunctioning
of the device
• KNX®and ETS® are registered trademarks of KNX As-
sociation cvba, Brussels
© Ekinex®S.p.A. The company reserves the right to make changes to this
documentation without notice.

7
Annex 1. Installation
The EK-ET2-TP... room temperature controller comes with
an integrated KNX communication module. It is suitable
for mounting into a ush-mounting box, either round (t)
or square (u), provided with xing holes 60 mm apart.
It can also be installed into a rectangular wall mounting
box (v) 3-seater according to the Italian installation
standard provided with xing holes 83,5 mm apart.
Each thermostat is delivered with its metal support (i, k)
which, in case of necessity, can also be ordered sepa-
rately. A plastic adapter and a terminal block complete
the supply.
The thermostat must be nished off with an operation
surface (rocker), a plate with 60 x 60 mm window and a
frame. The rocker (i) is available in a square shape, in
plastic material and in three different colours.
Each device has integrated eight displaying LEDs with
lightguides for feedback status and 3 sensors.
The square (r, r1) and rectangular (s, s1) frames are
available in two stylish alternatives (form and ank) and
share the same choice of materials, colours and ni-
shings as for rocker.
The ‘NF versions of the device are mounted without
frame and are provided with a side prole in white or
black colour.
Description Code
a) Thermostat EK-ET2-TP for square ush-mounting box EK-ET2-TP
b) Thermostat EK-ET2-TP-R for rect. ush-mounting box EK-ET2-TP-R
c) Square plate Surface series* EK-SQS-...
d) Square plate* EK-PQS-...
e) Square plate Deep series* EK-DQP-...
f) Rectangular plate Deep series* EK-DRS-...
g) Rectangular plate* EK-PRS-...
h) Rectangular plate Surface series* EK-SRS-...
i) Square rocker EK-T1Q-...
j) Metal mounting support EK-SMQ-71
k) Metal mounting support with adapter EK-SMR-71**
l) Adapter for square Surface plate EK-TAS-Q-...-NF
m) Adapter for square plate** EK-TAQ-...
Description Code
n) Adapter for square plate ‘NF and Deep series EK-TAQ-...-NF
o) Adapter for rectangular plate ‘NF and Deep series EK-TAR-...-NF
p) Adapter for rectangular plate** EK-TAR**
q) Adapter for Surface rectangular plate EK-TAS-R-...
r) Square frame Flank series EK-FLQ-...
r1) Square frame Form series EK-FOQ-...
s) Rectangular frame Flank series EK-FLR-...
s1) Rectangular frame Form serie EK-FOR-...
t) Round ush-mounting box not delivered by ekinex®
u) Square ush-mounting box not delivered by ekinex®
v) Rectangular ush-mounting box (3 modules) not delivered by ekinex®
*) 60 x 60 mm window
**) Included in the supply of the thermostat
Legenda
g
f
e
lj
n
m
h
b
a
c
d
i
o
q
r
s
s1
t
u
v
k
p
r1

8
Annex 2. Finalising
form
ank
‘NF
60 x 60 mm 60 x 60 mm
55 x 55 mm 60 x 60 mm
60 x 60 mm
60 x 60 mm 60 x 60 mm
55 x 55 mm 60 x 60 mm
60 x 60 mm
60 x 60 mm 60 x 60 mm
55 x 55 mm 60 x 60 mm
60 x 60 mm
Square form frame,
square plate
Rectangular form frame,
rectangular plate
Double form frame,
double plate
Square ank frame,
square plate
Rectangular ank frame,
rectangular plate
Double ank frame,
double plate
Square plate
Rectangular plate Double plate
Other manuals for EK-ET2-TP
1
This manual suits for next models
1
Table of contents
Other Ekinex Controllers manuals

Ekinex
Ekinex EK-HH1-TP Instructions for use

Ekinex
Ekinex EK-HE1-TP User manual

Ekinex
Ekinex 71 Series User manual

Ekinex
Ekinex EK-AG1-TP User manual

Ekinex
Ekinex KNX FF Series User manual

Ekinex
Ekinex EK-HA1-TP User manual

Ekinex
Ekinex EK-FE1-TP User manual

Ekinex
Ekinex EK-ES2-TP Instructions for use

Ekinex
Ekinex EK-GC1-TP User manual

Ekinex
Ekinex EK-HH1-TP User manual