eks EL-100-X User manual

Bedienungsanleitung Manual
MAN_EL-100-X
Version:
3.8
/ 19.06.2020
Freigabe:
U.A.
Seite 1 von 5
EL-100-X
Art.-Nr.: 0 4800 01 XX XX
eks Engel FOS GmbH & Co. KG
Schützenstraße 2-4
57482 Wenden-Hillmicke
Germany
Tel: +49 (0) 2762 9313-600
Fax: +49 (0) 2762 9313-7906
Internet: www.eks-engel.de
Rechtliche Hinweise
Legal Notice
Diese Anleitung enthält wichtige Anmerkungen und Warnungen, deren Nichtbe-
achtung zu ernsthaften Personen- oder Anlageschäden führen kann. Bitte lesen
Sie die Anleitung vor Inbetriebnahme der EL-100-X Geräte aufmerksam durch.
Ordnungsgemäßer Transport, korrekte Lagerung und Installation sowie sorgfältige
Bedienung und Instandhaltung der EL-100-X sind entscheidend für den sicheren
Betrieb.
This manual contains important notes and warnings. Their ignoration can cause
serious injuries or damages to the system. Please read the manual carefully
before using the equipment EL-100-X. Correct transport, proper storage and
installation as well as careful operation and maintenance of EL-100-X are critical
for safe operation.

Bedienungsanleitung Manual
MAN_EL-100-X
Version:
3.8
/ 19.06.2020
Freigabe:
U.A.
Seite 2 von 5
Systembeschreibung
System description
Die Serie EL-100X sind 4-Port unmanaged Industrial Ethernet Layer 2
Switche. Sie zeichnen sich durch einfache Funktionalität und Bedienfreundlichkeit
wie Auto-Negotiation und Auto MDI/MDIX aus sowie einem erweiterten
Temperaturbereich aus.
Die kompakte Bauform im industriellen Design zeichnet sich vor allem durch ihre
hohe Flexibilität bei der Konfiguration aus. So können bis zu 2 FX-Ports beliebig
bestückt werden. Als optische Anschlussvariante stehen neben ST und SC auch
E-2000® zur Verfügung. Alle Systeme können sowohl über zwei Fasern als auch
über eine Faser durch BIDI-Technik mit SC-Anschluss kommunizieren
Als wichtige Leistungsmerkmale der Übertragung mit Kunststofffaser-, HCS,
Multimode- oder Singlemode-Lichtwellenleitern gelten die Unempfindlichkeit
gegenüber elektrischen und magnetischen Störungen, die Potenzialtrennung von
Sender und Empfänger sowie Reichweiten bis zu 40 km zwischen zwei LWL-
Systemen. LEDs und optional potenzialfreie Kontakte eines Fehlerrelais
signalisieren fehlerhafte Zustände.
Series EL-100X is 4-Port unmanaged Industrial Ethernet Layer 2 Switches
with Auto-Negotiation and Auto MDI/MDIX for extended temperature ranges.
The rugged and compact housing allows a flexible FX-Port configuration. Up to 2
FX-Ports are available, each having a ST, SC or an E-2000® fiber optic
connector. All systems can communicate via two or one fiber with the help of BIDI-
technology with SC port.
Important performance features of the transfer with POF, HCS, multimode or
singlemode fiber optic are the electromagnetic ruggedness, the potential
separation of transmitter and receiver, as well as ranges up to 40 km between two
fiber optic systems. LEDs and potential-free contacts (optional) of a fault detector
relay are able to signal defective states.
Anschlusshinweise
Hardware Installation
Achtung: Beim Betrieb elektrischer Betriebsmittel und Anlagen stehen zwangs-
läufig bestimmte Teile unter gefährlicher Spannung. Arbeiten an elektrischen
Anlagen oder Betriebsmitteln dürfen nur von einer Elektrofachkraft oder von
unterwiesenen Personen unter Anleitung und Aufsicht einer Elektrofachkraft,
den elektrotechnischen Regeln entsprechend, vorgenommen werden.
Schalten Sie die Systeme und Endgeräte spannungsfrei.
Rasten Sie das Gerät auf eine Tragschiene DIN EN auf, und überprüfen Sie den
sicheren Halt!
Achtung: Benutzen Sie nur die zugehörigen LWL-Anschlussstecker. Wir weisen
ausdrücklich daraufhin, dass der Anschluss mit falschen Steckverbinder
Schäden an den optischen Anschlüssen hervorrufen kann! Beachten Sie
zudem, dass die Stecker, die eine Verriegelung besitzen, nur in einer
definierten Position montiert werden können.
Achtung: Sehen Sie nicht in den optischen Sender! Das gebündelte und
abhängig von der Wellenlänge sichtbare oder unsichtbare Licht kann zu
Augenschäden führen!
Verbinden Sie den ankommenden Lichtwellenleiter mit dem optischen Empfänger
und den abgehenden LWL mit dem optischen Sender des LWL-System.
Benutzen Sie die beigefügten Stopfen um Sender und Empfänger des LWL-
System im nicht eingebauten oder nicht benutzten Zustand vor
Verunreinigungen oder Staub zu schützen.
Achtung: Knicken Sie das LWL-Kabel nicht zu stark und beachten Sie den
Biegeradius des Kabelherstellers. Andernfalls kann das Kabel beschädigt
werden und/oder die Kommunikation zwischen den LWL-Wandlern nicht mehr
gewährleistet werden
Schalten Sie die Betriebsspannung für die LWL-Systeme ein. Zur Versorgung der
Systeme wird eine Betriebsspannung von 24 VDC benötigt, die an die
Klemmen VDC1 oder VDC2 und GND angelegt wird. VDC1 und VDC2 sind
redundante Versorgungsspannungseingänge mit Verpolungsschutz.
Achtung bei Systemen mit BIDI: Bei Verwendung von Systemen mit optischem
BIDI-Anschluss müssen immer die optischen Anschlüsse (Transceiver) vom
Typ A mit Typ B verbunden werden. Bei Systemen mit 2 FX-Ports ist der
optische Anschluss (Transceiver) mit dem Typ A immer der obere Anschluss.
Funktion der Status-LEDs:
VDC :+24 V Versorgungsspannung liegt an VDC1 oder
VDC2
FAIL : Fehlerrelais geöffnet
Link/Act :Datenverkehr
10/100 : leuchtet grün bei Datenverkehr mit 100 Mbit/s
Funktion der Kontakte K1 - K2: Nicht belegt, nur auf Anfrage erhältlich.
Funktion der Kontakte K3 - K4: Nicht belegt, nur auf Anfrage erhältlich.
Die Systeme der Serie e-light verfügen über Auto-Negotiation und Auto
MDI/MDIX.
Power off the devices, which will be connected by using the fiber optic system.
Snap the system onto the DIN EN rail and check the correct holding!
Attention: Only use the correct optical connectors for the fiber optic system.
Using incorrect connectors can cause damage to the fiber optic system. Take
care that connectors with a latch can only be mounted in a defined position.
Attention: Don't stare into the optical cable or the transmitter of the fiber optic
system. Visible and non visible light (depending on its wavelength) of the
optical transmitter can cause eye-damages!
Connect the fiber optic system by using the correct fiber optic cable. Take care
that you always have to connect an optical transmitter and an optical receiver.
Use the plugs to save the unused optical receiver and transmitter against impurity.
Attention: Don't bend the fiber optic cable! Please refer to the manufacturer’s
specifications. Otherwise the fiber optic cable can be damaged and/or the
communication will be disturbed.
Power on the devices. Please use a power supply of 24 VDC, connected to the
terminals marked with VDC1, VDC 2 and GND. Note that VDC 1 and VDC 2 are
redundant power inputs with reverse voltage protection.
Attention: BIDI Switches must always be connected from transceiver type A to a
transceiver type B. Switches with 2 FX-Ports always have the transceiver type
A as the upper one.
Function of the Status-LEDs:
VDC :+24 V Power Supply at VDC1 or VDC2
FAIL : Failure relay opened
Link/Act :data traffic
10/100 : lights green at 100 Mbit/s
Function of K1 –K2: Not connected; only on request.
Function of K3 –K4: Not connected; only on request.
All switches of the e-light series features Auto-Negotiation und Auto MDI/MDIX.

Bedienungsanleitung Manual
MAN_EL-100-X
Version:
3.8
/ 19.06.2020
Freigabe:
U.A.
Seite 3 von 5
Ansicht / Views
1 FX(ST) / 2TX
2 FX(SC) / 2 TX
2 FX(E-2000®) / 2
TX
2 FX(SC-BIDI) / 2
TX
2 FX
Anschlussbilder / Schematics
light
-
light
-
light
-
light
-
Systembeschreibung mit BIDI / System Description with BIDI
Bei Verwendung von Systemen mit optischem BIDI-Anschluss
müssen immer die optischen Anschlüsse (Transceiver) vom Typ
A mit Typ B verbunden werden. Bei Systemen mit 2 FX-Ports ist
der optische Anschluss (Transceiver) mit dem Typ A immer der
obere Anschluss.
BIDI-Switches always have to be connected from
transceiver type A to a transceiver type B. Switches with 2
FX-Ports always have the transceiver type A as the upper
one.
Entsorgungshinweis
Disposal notes
Die Geräte dürfen nicht über den normalen Hausmüll entsorgt werden,
sondern können bei eks Engel FOS GmbH & Co. KG entsorgt werden.
The units must not be disposed with normal household waste but can
be returned to eks Engel FOS GmbH & Co. KG for disposal.

Bedienungsanleitung Manual
MAN_EL-100-X
Version:
3.8
/ 19.06.2020
Freigabe:
U.A.
Seite 4 von 5
Typenauswahl und Technische Daten
Type Selection and Technical Data
Ausführung
Type
4TX
3TX-1FX
-ST-MM
2TX-2FX
-ST-MM
3TX-1FX
-ST-SM
2TX-2FX
-ST-SM
2TX-2FX-MM-
ST-SM-ST-L
Bestell-Nr. EL-100-X
Order No.
0 4800 01
0000
0 4800 01
00 31
0 4800 01
31 31
0 4800 01
00 51
0 4800 01
51 51
0 4800 01
31 51-MIX-L
-
100 FX ports
-
1 x ST
2 x ST
1 x ST
2 x ST
2 x ST
-
Ausführung
Type
-
3TX-1FX
-SC-MM
2TX-2FX
-SC-MM
3TX-1FX
-SC-SM
2TX-2FX
-SC-SM
2TX-2FX-MM-
SC-SM-SC-L
Bestell-Nr. EL-100-X
Order No.
-
0 4800 01
00 33
0 4800 01
33 33
0 4800 01
00 53
0 4800 01
53 53
-
0 4800 01
33 53-MIX-L
100 FX ports
-
1 x SC
2 x SC
1 x SC
2 x SC
-
2 x SC
Ausführung
Type
-
3TX-1FX
-SC-MM-BIDI
2TX-2FX
-SC-MM-BIDI
3TX-1FX
-SC-SM-BIDI
2TX-2FX
-SC-SM-BIDI
-
-
Bestell-Nr. EL-100-X BIDI
Order No.
-
0 4800 01 00 36
BIDIA
04800 01 00 37
BIDIB
0 4800 01 36 37
BIDI
0 4800 01 00 56
BIDIA
048000 1 00 77
BIDIB
0 4800 01 56 77
BIDI
-
-
100 FX ports
-
1 x SC
2 x SC
1 x SC
2 x SC
-
-
Faserart
Fiber
-
Multimode
Singlemode
Kanal 1 (K1): Multimode
Kanal 2 (K2): Singlemode
Fasertyp
Fiber type
-
50/125µm / 62,5/125µm
9/125µm
K1: 50/125µm 62,5/125µm
K2: 9/125µm
Faserspezifikation
Fiber specification
-
800 MHz*km / 500 MHz*km
Bandbreite / Bandwidth
3,5 ps/nm*km
Dispersionskoeffizient / Dispersion
K1: 500 (800) MHz*km
K2: 3,5 ps/nm*km
Wellenlänge
Wavelength
-
1300 nm
(BIDI: 1300 nm / 1550 nm)
1310 nm
(BIDI: 1310 nm / 1550 nm)
Budget
Budget
-
12 dB
3 dB Systemreserve
16 dB
3 dB Systemreserve
K1: 12 dB
K2: 16 dB
Distanzen max.
Distances max
-
5 km
(1 dB/km)
4 km
(1 dB/km)
30 km
(0,3 dB/km)
K1: 5 km (1 dB/km)
K2: 30 km (0,3 dB/km)
10/100Base T/TX Ports
4
3
2
3
2
-
RJ45 / Autonegotiation / Auto MDX/MDIX / unterstützt Längen bis 100 m / supports cable till 100 m (Cat5e)
Stromversorgung
Input power
12-30 VDC redundante Spannungsversorgung ( weitere Spannungen auf Anfrage)
12-30 VDC redundant power supply (other voltages on request)
Leistungsverbrauch
Power consumption
5 W
5,7 W
6,4 W
5,7 W
6,4 W
6,4 W
Potentialtrennung
Isolation
500 V
Abmessungen B x H x T
Dimensions W x H x D
B: 61 mm, H: 115 mm, T: 113 mm
W: 61 mm, H: 115 mm, D: 113 mm
Gewicht
Weight
500 g
Gehäuse / Schutzart
Enclosure / IP-Code
Edelstahl, pulverbeschichtet / IP 20
Stainless steel, lacked / IP 20
MTBF
MTBF
901753,9114 h / 102,9399442 Jahre
901753,9114 h / 102,9399442 years
Lagertemperatur
Temperature (storage)
-40 °C - +85 °C
Betriebstemperatur
Operation temperature
-40 °C - +70 °C (Multimode or Singlemode with ST or SC)
-20 °C - +55 °C (all others)
Feuchtigkeit
Humidity
Feuchtigkeit 5-95% RHD nicht kondensierend
Humidity 5-95% RHD non-condensing
EMV
EMC
EN61000-6-2 / EN55022 Class B +A1 + A2
LED Anzeige
LED indications
Systemfehler (rot) / Port LEDs (gelb/grün) / Stromversorgung (grün)
System failure (red) / Port LEDs (green/ yellow) / power supply (green)

Bedienungsanleitung Manual
MAN_EL-100-X
Version:
3.8
/ 19.06.2020
Freigabe:
U.A.
Seite 5 von 5
Fehlerrelais
Failure relay
potentialfreier Relaiskontakt (schaltet bei internem Spannungsfehler)
Potential Free Relay (switches if internal power supply fails)
Technische Änderungen vorbehalten. Für Irrtümer und Druckfehler keine Haftung. © eks Engel FOS GmbH & Co. KG
Reserve technical changes. No liability is accepted for errors and printing errors. © eks Engel FOS GmbH & Co. KG
This manual suits for next models
17
Table of contents
Other eks Switch manuals

eks
eks e-light-1000-4G User manual

eks
eks EL1100-4AC Series User manual

eks
eks e-Light2 EL100-2U Series User manual

eks
eks e-light 2M User manual

eks
eks e-light 2M User manual

eks
eks EL1000-2G User manual

eks
eks e-light 2MA User manual

eks
eks PE-LIGHT-2 User manual

eks
eks e-light2 EL100U2 Operating and installation instructions

eks
eks EL100X User manual
Popular Switch manuals by other brands

Moxa Technologies
Moxa Technologies EtherDevice EDS-828 Series Quick installation guide

ORiNG
ORiNG TGPS-9168GT-M12 Quick installation guide

Renkforce
Renkforce 1208454 operating instructions

Siemens
Siemens SENTRON 3NJ621 operating instructions

3Com
3Com Switch 4500 Family datasheet

Swedstyle
Swedstyle LOGIClink manual