PRODUCT DATA SHEET
2-9SM PXD 1-E.3 GB
2.9 PXD 30 / OU8-30 R410A
Model Indoor Unit PXD 30
Model Outdoor Unit OU8-30
Installation Method of Pipe Flared
Characteristics Units Cooling Only Cooling Heating
Capacity (1) Btu/hr 29,100 29,100 29,500
kW 8.52 8.52 8.65
Power input (1) kW 2.99 2.99 2.79
EER (Cooling) or COP(Heating) (1) W/W 2.85 2.85 3.10
Energy efficiency class C C D
Power supply V/Ph/Hz 220-240V/Single/50Hz
Rated current A 12.2 12.2 11.3
Starting current A 80
Circuit breaker rating A 25
INDOOR
Fan type & quantity Centrifugal x 2
Fan speeds H/M/L RPM 1360/1200/1010
Air flow (2) H/M/L m3/hr 1020/895/700
External static pressure Min-Max Pa N/A
Sound power level (3) H/M/L dB(A) 68/64/60
Sound pressure level(4) H/M/L dB(A) 56/53/49
Moisture removal l/hr 3.4
Condensate drain tube I.D mm 16
Dimensions WxHxD mm 1200x630x190
Weight kg 32
Package dimensions WxHxD mm 1270x710x280
Packaged weight kg 36
Units per pallet units 7
Stacking height units 7 Levels
OUTDOOR
Refrigerant control Capillary
Compressor type, model Rotary, Mitsubishi NN33VAAMT
Fan type & quantity Propeller(direct) x 1
Fan speeds H/L RPM 850
Air flow H/L m3/hr 3150
Sound power level H/L dB(A) 69
Sound pressure level(4) H/L dB(A) 59
Dimensions WxHxD mm 900x860x340
Weight kg 78
Package dimensions WxHxD mm 985x907x435
Packaged weight kg 82
Units per pallet Units 6
Stacking height units 2 Levels
Refrigerant type R410A
Refrigerant chargless distance kg/m 2.42kg/15m
Additional charge per 1 meter g/m 30
Connections between units
Liquid line In.(mm) 3/8"(9.53)
Suction line In.(mm) 5/8"(15.88)
Max .tubing length m. Max.30
Max .height difference m. Max.15
Operation control type Remote control
Heating elements kW
Others Crankcase heater (50W)
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.