manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Electrolux
  6. •
  7. Chiller
  8. •
  9. Electrolux 726622 User manual

Electrolux 726622 User manual

Electrolux Blast Chillers
Blast Chillers - 28 kg
Chilling means bringing the temperature of cooked food from +90ºC to +3°C in a short time lap which does not
allow bacterial growth. Electrolux Blast Chillers reduce temperature from +90ºC to +3°C at food core in less
than 90 minutes: the models detailed on this sheet performs this cycle up to a 28 kg full load. After the Blast
Chilling a holding cycle starts automatically to maintain food at +3°C. Blast chilled food has a solid 5 days shelf
life without loss of flavour, nutritional values and weight. The opportunity to prepare in a single shot the food to
be used in different times during the week enables a better work scheduling and therefore a sensible reduction
in labour costs. The range of Electrolux Blast Chillers crosswise consists of 5 models with built in or remote
refrigerating unit that offer an excellent all-round performance.
Model 726622
OPERATING MODES
• Soft Chilling (Air temperature –2°C).
• Hard Chilling (Air temperature
–12°C).
• All the probe-driven cycles feature
ARTE (Algorithm for Remaining Time
Estimation) to make planning the
activities easier.
• Holding at +3°C (automatically
activated at the end of each cycle).
• Turbo cooling: the chiller works
continuously at the desired
temperature. Ideal for continuous
production.
• Automatic recognition of the
insertion of the food probe (cycles
piloted either by food probe
temperature or by time).
• The control unit provides several
operating settings: time/core
temperature according to NF and UK
regulations, time/air
temperature/probe personalised
according to national regulations,
sterilizing cycle: UV lamps built-in (on
request), 3 single sensor or 3-sensor
temperature probes (as accessory),
ideal for meats, automatic defrosting
and manual defrosting. All parameters
are programmable.
• Single sensor core probe as
standard.
• The control unit provides two large
displays to read out: time, core
temperature, cycle countdown,
alarms, service information.
• Two customizable cycles (P1 & P2)
for each operating mode, allowing to
set the time and air temperature.
These programs can be converted
into ice-cream specialized cycles
(shape maintainance and holding).
• All information related to the
different operating models are
recorded: date, time, cycle, core
temperature, holding temperature,
HACCP accordance.
• An audible alarm starts when the
cycle ends or terminates abnormally.
PERFORMANCE
• Chilling times can vary according to
food quantity, density, moisture
contents and type of containers.
Chilling capacity according to NF*
regulations is 18 kg.
Electrolux Blast Chillers
Blast Chillers - 28 kg
Internet: http://www.electrolux.com/foodservice
HDAA0202011-05-10Subject to change without notice
TROLLEY FOR 10XGN1/1 ROLL IN RACK 922130 922130
TROLLEY FOR 10X1/1 & 2/1 ROLL IN RACK 922128 922128
ROLL-IN RACK SUPPORT BC+BCF 28KG 10GN1/1 881518 881518
RILSAN COATED GRID 881061 881061
PRINTER FOR HACCP BASIC VERSION 881532 881532
PLASTIC COATED GRID-600X400 MM 880864 880864
PAIR OF 1/1 GN AISI 304 S/S GRIDS 921101 921101
KIT TO CONVERT TO 10X1/1 SLIDE-IN RACK 922201 922201
KIT HACCP EKIS 922166 922166
KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW 880183 880183
80 MM PITCH SIDE HANGERS 10X1/1 GAS 0VEN 922116 922116
80 MM PITCH SIDE HANGERS 10X1/1 ELE.OVEN 922115 922115
60 MM PITCH SIDE HANGERS 10X1/1 GAS OVEN 922122 922122
60 MM PITCH SIDE HANGERS 10X1/1 ELE.OVEN 922121 922121
4 WHEELS FOR BLAST CHILLERS 881097
3-POINT-SENSOR PROBE-BL.C/FREEZERS LW 880212 880212
1 SINGLE-SENSOR PROBE-BL.C/FREEZERS LW 880213 880213
ACCESSORIES
1 SINGLE-SENSOR PROBE-BL.C/FREEZERS LW 1 1
INCLUDED ACCESSORIES
Net weight - kg. 124 114
installed-electric 1.1 0.12
Power - kW
at evaporation temperature - °C -5 -5
Refrigerant power
Refrigeration power - W 1436 1700
Refrigerant quantity - g. 1530
Refrigerant type R134a R134a
N° defrost in 24 hrs. 6 6
Compressor power - HP 3/4
Max load capacity - trays h 65 mm - n° 6 6
Trays type GN 1/1; 600x400 GN 1/1; 600x400
Door hinges Right Side Right Side
N° and type of door 1 1
height 1640 1640
depth/with open doors 760, 1500 770, 1450
width 760 760
External dimensions - mm
Cooling unit Built-In Remote
Gross capacity (D.I.N. 8952) - l. 210 210
UK Guide lines - chilling / freezing 28 28
NF Regulations - chilling / freezing 21.6 21.6
Productivity per cycle - kg.
Type C - 28 KG CHILLER C - 28 KG CHILLER
TECHNICAL DATA
RBC101
726622
RBC101R
726623
CONSTRUCTION
• Internal and external finishing in 304
AISI stainless steel and backpanel in
galvanized steel.
• High density polyurethane
insulation, 60 mm tickness, HCFC
free.
• Environmentally friendly: R404a as
refrigerant fluid.
• Developed and produced in ISO
9001 and ISO 14001 certified factory.
• Inner cell with fully rounded corners.
• Door equipped with removable
magnetic gasket with hygienic design.
• Motors and fan waterproof
protected IP21.
• Evaporator with antirust protection.
• Ventilator (fan) swinging hinged
panel for access to the evaporator for
cleaning.
• Automatic heated door frame.
• Thermostatic expansion valve to
optimize the cooling unit efficiency.
• Adjustable feet 150 mm high.
• Stand alone printer as accessory.
• PC connection on request, gate RS
485.

INSTALLATION
• No water connections required.
• Waste water can be plumbed into
drain, but can also be collected in an
optional waste container.
*NF HYGIENE ALIMENTAIRE
certifying authority : AFAQ AFNOR
CERTIFICATION. Adress:11, Avenue
Francis de Pressense - 93571
Saint-Denis La Plaine Cedex - France.
Conformity with regulation NF031.
Certified guarantees: fitness for
cleaning, thermal performance.
Electrolux Blast Chillers
Blast Chillers - 28 kg
Internet: http://www.electrolux.com/foodservice
HDAA0202011-05-10Subject to change without notice
EI - Electrical connection 230 V, 1N, 50
LEGEND
RBC101
726622
726622
Electrolux Blast Chillers
Blast Chillers - 28 kg
Internet: http://www.electrolux.com/foodservice
HDAA0202011-05-10Subject to change without notice
RI - Remote refrigeration connection ●
EI - Electrical connection 230 V, 1N, 50
ED - Remote electrical connection ●
D - Water drain 1/2"
LEGEND
RBC101R
726623
726623

This manual suits for next models

3

Other Electrolux Chiller manuals

Electrolux Air-O-Chill 726865 User manual

Electrolux

Electrolux Air-O-Chill 726865 User manual

Electrolux 10 GN 1/1 User manual

Electrolux

Electrolux 10 GN 1/1 User manual

Electrolux ZANUSSI EasyChill BCFW102 User manual

Electrolux

Electrolux ZANUSSI EasyChill BCFW102 User manual

Electrolux Air-O-Chill 727154 User manual

Electrolux

Electrolux Air-O-Chill 727154 User manual

Electrolux Air-O-Chill AOFP061C User manual

Electrolux

Electrolux Air-O-Chill AOFP061C User manual

Electrolux 10 GN 2/1 User manual

Electrolux

Electrolux 10 GN 2/1 User manual

Electrolux air-o-convect 20 GN 2/1 User manual

Electrolux

Electrolux air-o-convect 20 GN 2/1 User manual

Electrolux EID60010X User manual

Electrolux

Electrolux EID60010X User manual

Electrolux 726620 User manual

Electrolux

Electrolux 726620 User manual

Electrolux Air-O-Chill 727151 User manual

Electrolux

Electrolux Air-O-Chill 727151 User manual

Electrolux KBB5X User manual

Electrolux

Electrolux KBB5X User manual

Electrolux 11 User manual

Electrolux

Electrolux 11 User manual

Electrolux HDAA030 User manual

Electrolux

Electrolux HDAA030 User manual

Electrolux BLAST CHILLER LW User manual

Electrolux

Electrolux BLAST CHILLER LW User manual

Electrolux Air-O-Chill AOFP201CRR User manual

Electrolux

Electrolux Air-O-Chill AOFP201CRR User manual

Electrolux EAT1AX User manual

Electrolux

Electrolux EAT1AX User manual

Popular Chiller manuals by other brands

Gree LSQWRF35VM/NaA-M Service manual

Gree

Gree LSQWRF35VM/NaA-M Service manual

Cornelius CH1500 Operator's & installation manual

Cornelius

Cornelius CH1500 Operator's & installation manual

Johnson Controls YORK YCAL0043E Series Installation operation & maintenance

Johnson Controls

Johnson Controls YORK YCAL0043E Series Installation operation & maintenance

Carrier Sanyo 16TJ Operation and maintenance instructions

Carrier

Carrier Sanyo 16TJ Operation and maintenance instructions

SMC Networks HRS018-A Operation manual

SMC Networks

SMC Networks HRS018-A Operation manual

Trane RTAA Installation operation & maintenance

Trane

Trane RTAA Installation operation & maintenance

Aquacal TropiCool TC500 Brochure & specs

Aquacal

Aquacal TropiCool TC500 Brochure & specs

York YCAQ10 manual

York

York YCAQ10 manual

Gree T1/R22 Service manual

Gree

Gree T1/R22 Service manual

REMKO RVS Series Operating and installation instructions

REMKO

REMKO RVS Series Operating and installation instructions

Nordcap SKF 15 GN 1/1 Installation

Nordcap

Nordcap SKF 15 GN 1/1 Installation

Haier CA0035EAND Service manual

Haier

Haier CA0035EAND Service manual

Daikin EWWD120MBYNN Operation manual

Daikin

Daikin EWWD120MBYNN Operation manual

Midea Aqua Tempo Super Series Technical & service manual

Midea

Midea Aqua Tempo Super Series Technical & service manual

BICOLD WBA Series User instructions

BICOLD

BICOLD WBA Series User instructions

York YD Mod D Operation manual

York

York YD Mod D Operation manual

Yazaki WFC-SC Series Installation

Yazaki

Yazaki WFC-SC Series Installation

Moffat Friginox RC15-7A Specifications

Moffat

Moffat Friginox RC15-7A Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.