Electrolux air-o-chill
Blast Chillers 100 kg - 20 GN 1/1
Chilling means bringing the temperature of cooked food from +90ºC to +3°C in a short time lap which does not
allow bacterial growth .Electrolux Blast Chillers reduce temperature from +90ºC to +3°C at food core in less
than 90 minutes: the model detailed on this sheet performs this cycle up to a 100 kg full load. After the Blast
Chilling a holding cycle starts automatically to maintain food at +3°C. Blast chilled food has a solid 5 days shelf
life without loss of flavour, nutritional values and weight. The opportunity to prepare in a single shot the food to
be used in different times during the week enables a better work scheduling and therefore a sensible reduction
in labour costs.
OPERATING MODES
• Cruise: the chiller automatically sets
the parameters for the quickes and
best chilling (it works by probe).
• Soft Chilling (Air temperature –2°C).
• Hard Chilling (Air temperature
–20°C).
• All the probe-driven cycles feature
ARTE (Algorithm for Remaining Time
Estimation) to make planning the
activities easier.
• Holding at +3°C (automatically
activated at the end of each cycle).
• Turbo cooling: the chiller works
continuously at the desired
temperature. Ideal for continuous
production.
• It is possible to operate by time or
by probe.
• The control unit provides several
operating settings: time/core
temperature according to NF and UK
regulations, time/air
temperature/probe personalised
according to national regulations,
sterilizing cycle: UV lamps built-in (on
request), 3 single sensor core
temperature probes (as accessory),
ideal for meats, automatic defrosting
and manual defrosting. All parameters
are programmable.
• 3-sensor core probe as standard.
• The control unit provides two large
displays to read out: time, core
temperature, cycle countdown,
alarms, service information.
• Two customizable cycles (P1 & P2)
for each operating mode, allowing to
set the time and air temperature.
These programs can be converted
into ice-cream specialized cycles
(shape maintainance and holding).
• All information related to the
different operating models are
recorded: date, time, cycle, core
temperature, holding temperature,
HACCP accordance.
• An audible alarm starts when the
cycle ends or terminates abnormally.
PERFORMANCE
• Blast Chilling cycle: 100 kg from
+90°C up to + 3°C in less than 90
minutes.
• Chilling times can vary according to
food quantity, density, moisture
contents and type of containers.
Chilling capacity according to NF*
regulations is 70 kg.
Electrolux air-o-chill
Blast Chillers 100 kg - 20 GN 1/1
Internet: http://www.electrolux.com/foodservice
HDAB0302009-10-06Subject to change without notice
WATER REMOTE UNIT BLAST CHILLER CW 100KG 880034
TROLLEY TRAY RACK F.16X1/1GN,80MM PITCH 922010
TROLLEY TRAY RACK F. 20X1/1GN,63MM PITCH 922007
THERMAL COVER FOR 20X1/1GN 922014
RILSAN COATED GRID 881061
PRINTER FOR HACCP BASIC VERSION 881532
PASTRY TROLLEY 16(400X600)80MM-20 1/1 LW 922068
PAIR OF 1/1 GN AISI 304 S/S GRIDS 921101
KIT HACCP EKIS 922166
KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW 880183
KIT 3 SINGLE SENSOR PROBES FOR BC/BCF 880269
BANQ.TROLLEY-54PLATES-74MM PITCH-20GN1/1 922016
BANQ.TROLLEY-45PLATES-85MM PITCH-20GN1/1 922072
AIR/WATER REMOTE UNIT F.BC+BCF LW 100KG 880059
AIR REMOTE UNIT CHILL+C/FREEZER CW 100KG 880031
2 SINGLE SENSOR PROBES CHILLER+C/FREEZER 880096
1 SINGLE SENSOR PROBE CHILLER+C/FREEZER 880089
ACCESSORIES
3-SENSOR PROBE FOR CHILLER+C/FREEZER 1
INCLUDED ACCESSORIES
installed-electric 0.88
Power - kW
at evaporation temperature - °C -10
Refrigerant power
Refrigeration power - W 13480
Refrigerant type R404a
N° defrost in 24 hrs. 6
Max load capacity - trays h 65 mm - n° 20
Trays type GN 1/1; 600x400
Door hinges Left
N° and type of door 1
height 1783
depth/with open doors 895
width 1040
External dimensions - mm
Thermometers Digital
Thermostat Electronic
Cooling unit Remote
UK Guide lines - chilling / freezing 100
NF Regulations - chilling / freezing 72
Productivity per cycle - kg.
Type Blast Chiller - 100 kg
TECHNICAL DATA
AOCP201CRR
727151
CONSTRUCTION
• Model AOCP061T available for
tower configuration (with a six grids
air-o-steam oven).
• Internal and external finishing in 304
AISI stainless steel and back panel in
stainless steel.
• High density polyurethane
insulation, 60 mm tickness, HCFC
free.
• Environmentally friendly: R404a as
refrigerant fluid.
• Developed and produced in ISO
9001 and ISO 14001 certified factory.
• Inner cell with fully rounded corners.
• Door equipped with removable
magnetic gasket with hygienic design.
• Motors and fan waterproof
protected IP20.
• Evaporator with antirust protection.
• Ventilator (fan) swinging hinged
panel for access to the evaporator for
cleaning.
• Automatic heated door frame.
• Solenoid valves.
• 1 thermostatic expansion valve.
• Feet 200 mm high.
• Stand alone printer as optional, built
in on request.
• PC connection on request, gate RS
485.

INSTALLATION
• No water connections required.
• Waste water can be plumbed into
drain, but can also be collected in an
optional waste container.
MOBILE RACK
• Model AOCP061 is compatible with
air-o-steam and air-o-cook ranges.

*NF HYGIENE ALIMENTAIRE
certifying authority : AFAQ AFNOR
CERTIFICATION. Adress:11, Avenue
Francis de Pressense - 93571
Saint-Denis La Plaine Cedex - France.
Conformity with regulation NF031.
Certified guarantees: fitness for
cleaning, thermal performance.

Installation diagram:

C - Water drain
I - Electrical connection
Y - Connection for appliance lifting
L - Remote electrical connection
N - Cooling water inlet
O - Cooling water outlet
Electrolux air-o-chill
Blast Chillers 100 kg - 20 GN 1/1
Internet: http://www.electrolux.com/foodservice
HDAB0302009-10-06Subject to change without notice
RI - Remote refrigeration connection ●
EI - Electrical connection 400 V, 3N, 50
ED - Remote electrical connection ●
D - Water drain 1/2"
LEGEND
AOCP201CRR
727151
727151

This manual suits for next models

2

Other Electrolux Chiller manuals

Electrolux 10 GN 1/1 User manual

Electrolux

Electrolux 10 GN 1/1 User manual

Electrolux Air-O-Chill AOFP061C User manual

Electrolux

Electrolux Air-O-Chill AOFP061C User manual

Electrolux 11 User manual

Electrolux

Electrolux 11 User manual

Electrolux KBB5X User manual

Electrolux

Electrolux KBB5X User manual

Electrolux EID60010X User manual

Electrolux

Electrolux EID60010X User manual

Electrolux 726622 User manual

Electrolux

Electrolux 726622 User manual

Electrolux air-o-convect 20 GN 2/1 User manual

Electrolux

Electrolux air-o-convect 20 GN 2/1 User manual

Electrolux BLAST CHILLER LW User manual

Electrolux

Electrolux BLAST CHILLER LW User manual

Electrolux HDAA030 User manual

Electrolux

Electrolux HDAA030 User manual

Electrolux Air-O-Chill 727154 User manual

Electrolux

Electrolux Air-O-Chill 727154 User manual

Electrolux ZANUSSI EasyChill BCFW102 User manual

Electrolux

Electrolux ZANUSSI EasyChill BCFW102 User manual

Electrolux EAT1AX User manual

Electrolux

Electrolux EAT1AX User manual

Electrolux Air-O-Chill 726865 User manual

Electrolux

Electrolux Air-O-Chill 726865 User manual

Electrolux 10 GN 2/1 User manual

Electrolux

Electrolux 10 GN 2/1 User manual

Electrolux 726620 User manual

Electrolux

Electrolux 726620 User manual

Electrolux Air-O-Chill AOFP201CRR User manual

Electrolux

Electrolux Air-O-Chill AOFP201CRR User manual

Popular Chiller manuals by other brands

Trane RTAA-70 Installation & maintenance guide

Trane

Trane RTAA-70 Installation & maintenance guide

Carrier Omnizone 50BVC Installation, Start-Up, Service and Controls Operation and Troubleshooting

Carrier

Carrier Omnizone 50BVC Installation, Start-Up, Service and Controls Operation and Troubleshooting

York YGWH 115 Installation, commissioning & operation

York

York YGWH 115 Installation, commissioning & operation

Galletti PERFORMA MPE Series Technical manual

Galletti

Galletti PERFORMA MPE Series Technical manual

SMC Networks HRR Series manual

SMC Networks

SMC Networks HRR Series manual

Daikin EWAQ016CAW Installation and operation manual

Daikin

Daikin EWAQ016CAW Installation and operation manual

Trane CVHE Troubleshooting

Trane

Trane CVHE Troubleshooting

Moffat Friginox TSR-11SC Specification sheet

Moffat

Moffat Friginox TSR-11SC Specification sheet

Gree GWH07AGA-K6DNA1C Service manual

Gree

Gree GWH07AGA-K6DNA1C Service manual

MP Systems PURGE Series manual

MP Systems

MP Systems PURGE Series manual

Penguin COLD THERAPY CHILLER owner's manual

Penguin

Penguin COLD THERAPY CHILLER owner's manual

Telemark TVP-2000 Operation, installation and service manual

Telemark

Telemark TVP-2000 Operation, installation and service manual

TICA MINI VRF CHR Series Installation & operation manual

TICA

TICA MINI VRF CHR Series Installation & operation manual

MAXA A68 Installation and operation manual

MAXA

MAXA A68 Installation and operation manual

AERMEC NRL FC 2000 installation manual

AERMEC

AERMEC NRL FC 2000 installation manual

SABROE ChillPAC operating manual

SABROE

SABROE ChillPAC operating manual

Aqua Optima Corona Instructions for use

Aqua Optima

Aqua Optima Corona Instructions for use

Nordcap SKF 5 GN 1 manual

Nordcap

Nordcap SKF 5 GN 1 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.