Electrolux air-o-chill
Blast Chiller/Freezers 100kg 20GN1/1
Chilling means bringing the temperature of cooked food from +90ºC to +3°C in a short time lap which does not allow
bacterial growth. Electrolux Blast Chillers/Freezers reduce temperature from +90ºC to +3°C at food core in less than 90
minutes and down to -18ºC in less than four hours: the model detailed on this sheet performs this cycle up to a 100 kg
full load. After the Blast Chilling/freezing process a holding cycle starts automatically to respectively maintain food at +3
and -18 °C. Blast freezed food has a solid 6 months/1 year shelf life without loss of flavour, nutritional values and weight.
The opportunity to prepare in a single shot the food to be used in different times during the week enables a better work
scheduling and therefore a sensible reduction in labour costs.
726292
OPERATING MODES
• Cruise: the chiller automatically sets
the parameters for the quickes and
best chilling (it works by probe).
• Soft Chilling (Air temperature –2°C).
• Hard Chilling (Air temperature
–20°C).
• Shock freezing (Low air temperature
adjustable up to -41ºC).
• Holding at +3°C or -18ºC
(automatically activited at the end of
each probe driven cycle).
• All the probe-driven cycles feature
ARTE (Algorithm for Remaining Time
Estimation) to make planning the
activities easier.
• Holding at +3°C (automatically
activated at the end of each cycle).
• Turbo cooling: the chiller works
continuously at the desired
temperature. Ideal for continuous
production.
• It is possible to operate by time or
by probe.
• The control unit provides several
operating settings: time/core
temperature according to NF and UK
regulations, time/air
temperature/probe personalised
according to national regulations,
sterilizing cycle: UV lamps built-in (on
request), 3 single sensor core
temperature probes (as accessory),
ideal for meats, automatic defrosting
and manual defrosting. All parameters
are programmable.
• 3-sensor core probe as standard.
• The control unit provides two large
displays to read out: time, core
temperature, cycle countdown,
alarms, service information.
• Two specialized cycles, P1 brings
down the ice-cream temperature to
-14°C (measured at the core when
probe is inserted). Once set
temperature is reacheed, the
temporary maintenance phase
automatically begins, holding the
-14°C temperature. P2 sets
temperature to -36°C / -40°C for an
indefinite amount of time, maintaining
the ventilation active. Temperature is
adjustable up to -40°C without
interrupting the cycle, allowing
ice-cream to be kept longer in the
freezer.
• All information related to the
different operating models are
recorded: date, time, cycle, core
temperature, holding temperature,
HACCP accordance.
• An audible alarm starts when the
cycle ends or terminates abnormally.
Electrolux air-o-chill
Blast Chiller/Freezers 100kg 20GN1/1
Internet: http://www.electrolux.com/foodservice
HDBB0302011-07-14Subject to change without notice
WATER REMOTE UNIT FOR C/FREEZER CW 100KG 880035
TROLLEY TRAY RACK 20X1/1GN,63MM PITCH-LW 922007
TROLLEY TRAY RACK 16X1/1GN,80MM PITCH-LW 922010
RILSAN COATED GRID 881061
PRINTER FOR HACCP BASIC VERSION 881532
PASTRY TROLLEY 16(400X600)80MM-20 1/1 LW 922068
PAIR OF 1/1 GN AISI 304 S/S GRIDS 921101
KIT HACCP EKIS 922166
KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW 880183
BANQ.TROLLEY-54PLATES-74MM PITCH-20GN1/1 922016
AIR/WATER REMOTE UNIT F.BC+BCF LW 100KG 880059
AIR REMOTE UNIT CHILL+C/FREEZER CW 100KG 880031
3-POINT-SENSOR PROBE-BL.C/FREEZERS LW 880212
3 SINGLE-SENSOR PROBES-BL.C/FREEZERS LW 880215
2 SINGLE-SENSOR PROBES-BL.C/FREEZERS LW 880214
1 SINGLE-SENSOR PROBE-BL.C/FREEZERS LW 880213
ACCESSORIES
3-POINT-SENSOR PROBE-BL.C/FREEZERS LW 1
INCLUDED ACCESSORIES
Net weight - kg. 200
installed-electric 0.88
Power - kW
at evaporation temperature - °C -30
Refrigerant power
Refrigeration power - W 5350
Refrigerant type R404a
N° defrost in 24 hrs. 6
Max load capacity - trays h 65 mm - n° 20
Trays type GN 1/1
Door hinges Left
height 1783
depth/with open doors 895, 1422
width 1040
External dimensions - mm
Thermometers Digital
Thermostat Electronic
Control type Electronic
Cooling unit Remote
UK Guide lines - chilling / freezing 100, 85
NF Regulations - chilling / freezing 72, 72
Productivity per cycle - kg.
Type Blast freezer - 100 kg
TECHNICAL DATA
AOFPS201CR
726292
PERFORMANCE
• Blast Chilling cycle: 100 kg from
+90°C up to + 3°C in less than 90
minutes.
• Blast Freezing cycle : 85 kg from
90ºC up to -18ºC in less than four
hours.
• Chilling and freezing times can vary
according to food quantity, density,
moisture contents and type of
containers. Chilling capacity
according to NF regulations is 72 kg.
CONSTRUCTION
• Automatic heated door frame.
• Internal and external finishing in 304
AISI stainless steel and back panel in
stainless steel.
• High density polyurethane
insulation, 60 mm tickness, HCFC
free.
• Environmentally friendly: R404a as
refrigerant fluid.
• Developed and produced in ISO
9001 and ISO 14001 certified factory.
• Inner cell with fully rounded corners.
• Door equipped with removable
magnetic gasket with hygienic design.
• All motors and fan waterproof
protected IP23.
• Evaporator with anti rust protection.
• Ventilator (fan) swinging hinged
panel for access to the evaporator for
cleaning.
• Hot gas defrosting system.
• Solenoid valves.
• 1 thermostatic expansion valve.
• Feet 200 mm high.
• Stand alone printer as optional, built
in on request.
• PC connection on request, gate RS
485.
INSTALLATION
• No water connections required.
• Waste can be plumbed into drain,
but can also be collected in optional
waste container.
Installation diagram:

EQ - Equipotential screw
RO - Refrigerant outlet
EH - HACCP
Electrolux air-o-chill
Blast Chiller/Freezers 100kg 20GN1/1
Internet: http://www.electrolux.com/foodservice
HDBB0302011-07-14Subject to change without notice
RI - Remote refrigeration connection ●
EI - Electrical connection 400 V, 3N, 50
ED - Remote electrical connection ●
D - Water drain 1/2"
LEGEND
AOFPS201CR
726292
726292

This manual suits for next models

1

Other Electrolux Chiller manuals

Electrolux HDAA030 User manual

Electrolux

Electrolux HDAA030 User manual

Electrolux ZANUSSI EasyChill BCFW102 User manual

Electrolux

Electrolux ZANUSSI EasyChill BCFW102 User manual

Electrolux 10 GN 2/1 User manual

Electrolux

Electrolux 10 GN 2/1 User manual

Electrolux EID60010X User manual

Electrolux

Electrolux EID60010X User manual

Electrolux Air-O-Chill AOFP061C User manual

Electrolux

Electrolux Air-O-Chill AOFP061C User manual

Electrolux KBB5X User manual

Electrolux

Electrolux KBB5X User manual

Electrolux 726622 User manual

Electrolux

Electrolux 726622 User manual

Electrolux air-o-convect 20 GN 2/1 User manual

Electrolux

Electrolux air-o-convect 20 GN 2/1 User manual

Electrolux 11 User manual

Electrolux

Electrolux 11 User manual

Electrolux Air-O-Chill 727151 User manual

Electrolux

Electrolux Air-O-Chill 727151 User manual

Electrolux EAT1AX User manual

Electrolux

Electrolux EAT1AX User manual

Electrolux Air-O-Chill 727154 User manual

Electrolux

Electrolux Air-O-Chill 727154 User manual

Electrolux 726620 User manual

Electrolux

Electrolux 726620 User manual

Electrolux BLAST CHILLER LW User manual

Electrolux

Electrolux BLAST CHILLER LW User manual

Electrolux Air-O-Chill 726865 User manual

Electrolux

Electrolux Air-O-Chill 726865 User manual

Electrolux 10 GN 1/1 User manual

Electrolux

Electrolux 10 GN 1/1 User manual

Popular Chiller manuals by other brands

Olimpia splendid Ci1 Sries Technical manual

Olimpia splendid

Olimpia splendid Ci1 Sries Technical manual

KKT chillers SC Series Operating	 instruction

KKT chillers

KKT chillers SC Series Operating instruction

Trane Airfinity XL IC140 manual

Trane

Trane Airfinity XL IC140 manual

United Technologies Carrier Touchpilot 30XW-V Installation, operation and maintenance instructions

United Technologies

United Technologies Carrier Touchpilot 30XW-V Installation, operation and maintenance instructions

Lauda UC 2 Operation manual

Lauda

Lauda UC 2 Operation manual

Dunham-Bush WCFX-E Series manual

Dunham-Bush

Dunham-Bush WCFX-E Series manual

KIRLOSKAR KAC Installation, start-up, operation

KIRLOSKAR

KIRLOSKAR KAC Installation, start-up, operation

Modena CC 3180 User manual book

Modena

Modena CC 3180 User manual book

SMC Networks HRS-R Series Operation manual

SMC Networks

SMC Networks HRS-R Series Operation manual

York YVAM INSTALLATION PROCEDURE

York

York YVAM INSTALLATION PROCEDURE

York YK-EP Operation and maintenance manual

York

York YK-EP Operation and maintenance manual

Carrier 30GX Series Installation, operation and maintenance instructions

Carrier

Carrier 30GX Series Installation, operation and maintenance instructions

Trane Symbio CVRF installation instructions

Trane

Trane Symbio CVRF installation instructions

York YCAS0685 manual

York

York YCAS0685 manual

Carrier 19FA Series installation instructions

Carrier

Carrier 19FA Series installation instructions

Telemark Cryogenics instruction manual

Telemark

Telemark Cryogenics instruction manual

AIREDALE TurboChill TCC1 Series installation manual

AIREDALE

AIREDALE TurboChill TCC1 Series installation manual

Lennox ECOLOGIC Series Installation, operation & maintenance manual

Lennox

Lennox ECOLOGIC Series Installation, operation & maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.