6
TEST FUNCTION verification of function (signal transmission test)
Push the Fce button, with the /button choose the tE:St function and
confirm it with the i. The Ad:r message appears on the display; push the
ibutton to send out a signal (the On: and OF:F messages alternate on
the display). The relay will be switched on/off several times in the receiver
(indicated by orange LED).
If communication fails, the Er:r1 message appears on the display within
2 minutes.
Check the receiver connection and repeat the procedure!
Anti-freeze protection
If the room temperature falls below 3 °C, the thermostat automatically switches the outlet and
the symbol appears on the display. In this way, BPT 102 prevents the heating system from
freezing. As soon as the temperature rises, it gradually resumes the preset mode.
Child lock
It enables locking of the keyboard as a protection against undesired
operation. Push the Fce button, then simultaneously the and .
The keyboard will be locked (keys inoperative).
LO:C message appears on the display shortly. Cancellation (unlocking) can be done by
simultaneously pushing the and buttons (keys are operative again).
In case of guarantee
or post-guarantee
service, send the
thermostat to the
distributor’s or manu-
facturer’s address.
CERTIFICATE OF GUARANTEE
(guarantee period for the product amounts to 2 years)
product No.: date of sale:
stamp of shop:
examined by:
DECLARATION OF CONFORMITY
We, ELEKTROBOCK CZ s.r.o., herewith declare that the product BPT102
conforms to the basic requirements and other corresponding provisions
of the Directive 1999/5/EC.
Issued: 01.05.2012 see www.elbock.cz
TECHNICAL PARAMETERS
ELEKTROBOCK CZ s.r.o.
Blanenská 1763
Kuřim 664 34
Tel.: +420 541 230 216
www.elbock.cz
MADE IN CZECH REPUBLIC
Receiver
Power supply 230 V/ 50 Hz
Communication type two-way
Frequency 433,92 MHz
Range 300 m (free area)
35 m (built-up area)
Sensitivity < -102 dBm
Output relay, max. 16 A
Protection IP20
Protection class II
Working temperature 0 °C to +40 °C
Dimensions (H×L×W) 110x80x31mm
Transmitter
Power supply
2 x1.5V alkaline AA
batteries (not included in
the delivery)
Communication type two-way
Hf power < 10 mW
Frequency 433,92 MHz
Hysteresis 0.5 °C
Adjustable temp. range +3 °C to 40 °C
Temperature setting by 0.5 °C
Measurement accuracy ± 0,5 °C
Protection IP20
Battery life heating season
Working temperature 0 °C to +40 °C
Dimensions (H×L×W) 76x114x25 mm
Operating hours
The sum total of the thermostat operating hours appears if you push three times the ibutton;
the LCD shows a value, such as 00:10, which means that the thermostat was switched on for
10 hours. The hours are set to zero if the thermostat is reset.
Pb
LEAD FREE
in compliance with s RoHS