Elko SHT-6 User manual

1
SHT-6
E
N
Time switch
with DCF control

2
3
4
5
6
8
9
10
11
12
14
18
20
22
23
24
25
Contents
Warning ..........................................................................................................
Characteristics ...............................................................................................
Technical parameters ....................................................................................
Device description .........................................................................................
Symbol, Connection, Load ............................................................................
Mode precedence, Language settings .........................................................
Menu overview ..............................................................................................
Control description .......................................................................................
Time and date setting ...................................................................................
Time program ................................................................................................
Setting the switching modes ........................................................................
Setting options ..............................................................................................
Overview of time zones ................................................................................
Reset ...............................................................................................................
An example of SHT-6 programming ............................................................
Battery replacement .....................................................................................

3
E
N
Warning
Device is constructed for connection in 1-phase
main alternating current voltage and must be in-
stalled according to norms valid in the state of
application. Connection according to the details
in this direction. Installation, connection, setting and servic-
ing should be installed by qualied electrician sta only, who
has learnt these instruction and functions of the device. This
device contains protection against overvoltage peaks and
disturbancies in supply. For correct function of the protection
of this device there must be suitable protections of higher de-
gree (A, B, C) installed in front of them. According to standards
elimination of disturbancies must be ensured. Before installa-
tion the main switch must be in position “OFF” and the device
should be de-energized. Don´t install the device to sources of
excessive electro-magnetic interference. By correct installation
ensure ideal air circulation so in case of permanent operation
and higher ambient temperature the maximal operating tem-
perature of the device is not exceeded. For installation and set-
ting use screw-driver cca 2 mm. The device is fully-electronic
- installation should be carried out according to this fact. Non-
problematic function depends also on the way of transporta-
tion, storing and handling. In case of any signs of destruction,
deformation, non-function or missing part, don´t install and
claim at your seller it is possible to dismount the device after its
lifetime, recycle, or store in protective dump.
Internal circuits and sensor circuits are not galvanically isolated
from the mains. No product circuits, including sensor circuits,
can be considered as ELVs.
Cable shield to the sensor, fullls a functional purpose in terms
of EMC does not fulll any protection or safety function and it
is not associated with any EP protection. It is not possible to
touch the shield as well as the other product wiring circuits!
Security against electric shock is ensured by reinforced insula-
tion product, cable, sensors and their correct and professional
installation.
The cable must be of a suitable dimension to meet the pa-
rameters to provide protection in the area of the over-voltage
category III.

4
Characteristics
Time switch with DCF control is used for the automatic real-
time controlling of appliances. The timer operates all year round
without the need for continuous maintenance, with minimum
operating costs and maximum savings of electrical energy (for
example for turning on heating, pumps, ventilators, public light-
ing etc.). Appliances can be controlled in regular time cycles or
based on a pre-set programme.
Time switch SHT-6 is synchronized by a DCF77 signal using ex-
ternal receiver DCRF-1. Time switch can operate independently
without a DCF receiver. In the case of a power supply interrup-
tion, the timer retains all set values required for its reliable activa-
tion after power is restored.
- Switching modes:
- Auto – automatic switching mode:
- Programme – switching based on a programme (astro or
time).
- Random – switches randomly in a 10–120 minute interval.
- Holiday – holiday mode – option of setting up a period for
which the timer will be blocked, i.e. will not switch based on
the set programmes.
- Manual – manual mode – option of controlling the indi-
vidual output relay manually
- Options of the automatic switching programme:
- Time programme – switching based on a pre-set time pro-
gramme
- Memory capacity for 100 time programmes (common for both
channels).
- Programming can be performed both when power is on or in
backup mode.
- Output relays only operate with a supply voltage of AC 230 V.
- Menu display selection – CZ / SK / EN / ES / PL / HU / RU (default
factory setting EN).
- Selection of automatic switching between summer / winter
time based on location.
- Backlit LCD display.
- Simple and easy setup using 4 control buttons.
- Sealable transparent cover on the front panel.
- The timer has a backup battery that preserves data in case of a
power supply failure (reserve backup time up to 3 years).
- Supply voltage: AC 230 V.
- 2-module, mounted onto a DIN rail, clamping terminals.
- After plugging the timer in for the rst time, the current time,
date and geographic location must be set for correct opera-
tion of the clock.
Settings can be done:
- manually: only if the DCF signal is disabled
- automatically: if the receiver DCFR-1 is connected and DCF
signal is enabled.

5
E
N
Technical parameters
Supply terminals:
Supply voltage:
Supply voltage tolerance:
Output
Number of contacts:
Rated current:
Switching capacity:
Peak current:
Switching voltage:
Mechanical life:
Electrical life (AC1):
Time circuit
Real time back-up:
Accuracy
- without DCF receiver:
Minimum interval:
Data stored for:
Program circuit
Number of memory places:
Program:
Data readout:
A1 - A2
AC 230V / 50 - 60Hz
-15 %; +10 %
1x changeover (AgSnO2)
16 A / AC1
4000 VA / AC1, 384 W / DC
30 A / <3s
250 V AC1 / 24 V DC
> 3x107
> 0.7x105
up to 3 years
max. ±1s/ day at 23°C
1 min.
min. 10 years
100
daily, yearly (up to year 2099)
LCD display, with back light
-10.. +55 °C
-30.. +70 °C
4 kV (supply - output)
any
DIN rail EN 60715
IP10 clips, IP40 from front panel
III.
2
solid wire max. 2x 2.5 or 1x 4
with sleeve max. 1x 2.5 or 2x 1.5
90 x 35.6 x 64 mm
121 g (without battery)
EN 61812-1, EN 61010-1
Other information
Operating temperature:
Storage temperature:
Electrical strength:
Operating position:
Mounting:
Protection degree:
Overvoltage category:
Pollution degree:
Max. cable size (mm2):
Dimensions:
Weight
Standards:

6
Supply voltage terminal A1
Display with back-light
Place for seal
Connectors for the DCFR-1 receiver
Control buttons
Output - channel (16-15-18)
Supply voltage terminal A2
Device description
Plug-In with battery backup

7
SHT-6
ManProgAuto + t
E
N
Indicates the day in the week
Indication
Indication of date/setting menu*
Control button PRG / +
Control button MAN1 / -
Control button OK
Control button MAN2 / ESC
Reset
CONTROL OF A DISPLAY WITH BACKLIGHT
Power on: Display is illuminated with a backlight for 10 seconds from the
last button press. The display continuously shows the settings – date,
time, day of the week, contact state and programme. Permanent on / o
is activated by simultaneous presses of the MAN, ESC, OK buttons. After
activating the permanent on/o, the display will ash briey.
Backup mode: After 2 minutes, the display switches to the sleep mode, i.e.
shows no information. The display can be activated by pressing any button.
* Displaying the date or status of DCF signal (switches after 4 s) status of
DCF signal:
Prohibited DCF reception: DCF Flashes OFF
Allow DCF reception: good signal - DCF OK
bad or no signal - DCF BAD
** If the time is not set, the time indication is ashing. If the time is set
(manually or automatically), the time indication lights permanently.
Time display**
Operating modes indication
12/24 hours format /
sunset - sunrise
Indication of the switch
program

8
cos φ ≥ 0.95 M M
M M
HAL.230V
K
AC12
x
AC1
250V / 16A
AC2
250V / 5A
AC3
250V / 3A
AC5b
1000W
AC6a
x
AC7b
250V / 3A
DC14
x
AC13
x
AC14
250V / 6A
AC15
250V / 6A
DC1
24V / 10A
DC5
24V / 2A
DC12
24V / 6A
DC13
24V / 2A
DC3
24V / 3A
DCF
15
16
A2
A1B2B1 18
A2 16 15 18
A1 G B1 B2
DCFR-1
N
L
Load
AC5a
Uncompensated
230V / 3A (690VA)
AC5a
Compensated
230V / 3A (690VA)
max. input C=14uF
Type of load
Contact material AgSnO2
Contact 16A
Type of load
Contact material AgSnO2
Contact 16A
Type of load
Contact material AgSnO2
Contact 16A
ConnectionSymbol
↯Sensing sensor on potential network
mains supply voltage.

9
PRG OK
+_OK
+_
ESC
Prog
OK
Auto Prog
time/date
Prog
options
Prog
language
Prog
Prog
Prog
Prog
ESPAnOL
Prog
Prog
E
N
Mode precendence
Mode precedence
display output mode
ON / OFF
manual control
ON / OFF holiday mode
ON / OFF time program Prog
mode with the highest
priority
Language settings
language
selection
language
options
- long press (>1s)
- short press (<1s)

10
Auto Prog Prog Prog
Menu overview
setting the display of
the time format
setting the display of
the date format
setting the display of
the week day
setting the switch from
summer to winter time
setting the date
setting the current time add a program
edit the program
delete a program
setting and adjusting
the time program
time
date
su-wi
week day
date form
time form
add
edit
delete
setting the time and date
manual mode
setting the holiday
mode
setting the auto switching
mode
switch modes
holiday
manual
AUTO
time/date time prog modes

11
Prog Prog E
N
PRG
enter the programming
menu
+_
browsing in menu
setting of values
+_
quick shifting during
setting of values
OK
enter the required
menu
conrmation
ESC
one level up
a step back
ESC
back to the starting
menu
Control description
Device diers short and long
button press. In the manual
marked as:
- short button press (<1s)
- long button press (>1s)
After 30s of inactivity (from the last
press of any button) will device
automatically returns into starting
menu.
setting the language
operating hours for
individual channels
setting time correction by
± 12.6 s / day
device options
language
operating ho
time correct
options end
the DCF mode settings
time zone settings
DCF signal
time zone

12
Auto
PRG OK OK
OK
OK
+_
+_
+_
+_
Prog Prog
ProgProg Prog
OKOK
+_+_+_
Prog Prog
OK
+_
Prog
OK
ESC
Prog Prog
OK
ESC
Prog Prog
ESC
Prog
Prog
Prog
Prog
OK
+_
Time and date setting
setting the hours
setting the
time
setting the
date
setting the
switch between
the summer /
winter time
setting the monthsetting the year setting the day
setting the minutes
setting the switch between the summer
and winter time depending on area
time/date time hour minute time
date year month day date
su-wi
su-wi eur
su-wi usa
su-wi rus
no su-wi
su-wi
time/date It is possible only if DCF signal
is not enabled (in the menu
OPTIONS set – DCF signal
enabled).

13
Prog
OK
OK
+_
+_
+_
ESC
Prog
Prog
Prog
Prog
Prog
Prog
Prog
Prog
OK
Prog
ESC
Prog
Prog
Prog
Prog
Prog
Prog
Prog
OK
+_
OK
Prog
Prog
OK
ESC
ESC
E
N
setting the
week day
date format
time format
week day
date form
16 sep 10
16/sep/10
16--sep--10
week day
date form
time form
time form
12h
24h
end
- long press (>1s)
- short press (<1s)

14
ProgAuto
PRG OK OK
+_
+_OK
Prog ProgProg Prog
Prog
OK
OK
+_
Prog
OK
Prog Prog
OK
+_
OK
+_
+_
OK
OK
Prog
Prog
OK
Prog
Prog
OK
Prog
Prog
add a program
Time program
program choice *
daily program
yearly program
adjusting the
daily program
edit program
time/date time prog add prog day prog
year prog
edit prog day prog
time program
display for channel
display for channel
display for channel
out
out
out
out
out
out

15
ProgProg Prog
OKOK
+_+_+_
OK
+_
Prog Prog
OK
+_
OK OK
Prog
Prog
+_
Prog Prog
OK
+_
OK
OK
+_
ESC
ESC
Prog
Prog
Prog
Prog
Prog
Prog
Prog
Prog
+_
Prog Prog
OK
+_
OK OK
Prog
OK
+_
ESC
Prog
Prog
Prog
Prog
Prog
Prog
Prog
Prog
E
N
setting the minutessetting the hour setting the program
activity on a week day
setting the monthsetting the year setting the day setting the minutessetting the hours
adjusting the
setting of hours
adjusting the
setting of minutes
adjusting the setting of program
activity on a week day
hour
hour
hour
day
month
year
minute
minute
minute
on
on
add
add
add
- long press (>1s)
- short press (<1s)

16
Prog
ESC
+_
Prog
Prog
OK
+_
+_
OK
Prog
OK
+_
Prog
OK
OK
Prog
Prog
* By shortly pressing OK , you can toggle between the program number and the display of its settings. Use +_to toggle preset
programs. By holding OK you can proceed with the required step - CHANGE / DELETE. If you do not want to proceed, press ESC to go
to the main settings without any change.
If the program memory is full, you will see full on the display.
If the programs memory is empty and you want to change or erase a program, the display will read EMPTY
choosing the
program *
adjusting the
yearly program
delete the
program
delete delete
end
year prog
prog
display for channel
out
out

17
ProgProg Prog
OKOK
+_+_+_
OK
Prog
+_
Prog Prog
OK
+_
OK
ESC
E
N
adjusting the
setting of the month
adjusting the
setting of the year
adjusting the
setting of the day
adjusting the
setting of minutes
adjusting the
setting of hours
year month day hour minute add
- long press (>1s)
- short press (<1s)

18
ProgAuto
PRG OK
OK
+_
+_
+_
+_
Prog
Prog
ESC
Prog
OK Prog
+_
OK
ProgProg Prog
OKOK
+_+_+_
OK
Prog
Prog
OK
ESC
OK
Prog
Prog
Prog
Prog
ESC
OK
+_
ESC
+_
Prog
Prog Prog
Prog
automatic
switch mode
holiday mode
setting the start of the holiday mode
manual mode
choosing the switching
program
switching on the
manual mode
modes auto
holiday on
on
year
holiday
inactive
manual
manual
end
month day
prog
auto
random
time/date
Setting the switching modes
modes
off

19
OK
ProgProg Prog
OKOK
+_+_+_
OK
ESC
Prog
E
N
- long press (>1s)
- short press (<1s)
setting the end of the holiday mode
year month day holiday
What you see on the display:
- when a random mode is activated - Random - the symbol is lit .
- vacation mode HOLIDAY:
- the illuminated symbol indicates the vacation mode.
- the ashing symbol indicates the vacation mode.
- the symbol is not illuminated if the vacation mode is not set or has
- when the manual mode is activated, the symbol is lit and the manually controlled channel is ashing.

20
Prog
OK
+_
+
+
_
_
OK OK
ESC
ESC
Prog
Prog
Prog
Prog Prog
Prog
OK OK
Prog
Prog
+_
OK
ESC
Prog
+_
ProgAuto
PRG OK
+_OK
+_
ESC
Prog Prog Prog
OK
Prog
Prog
Prog
Prog
ESPAnOL
Prog
Prog
Settings options
Time correction:
The shift unit is 0.1s per day.
The numeric value refers to seconds per 10 days.
Time correction is factory-set and individual
for each product so that the real-time clock
would run with minimum deviation. The time
correction value can be arbitrarily adjusted, but
after product RESET, the value returns to factory
settings.
operating
hours
total number of hours of switching
when the device is connected to
the selected channel
time correction by
±12.6 s/day
time
correction
operating
time corr
time corr
time corr
time corr
clear operating
language
choice
time/date options language language
operating
show
options
Other manuals for SHT-6
3
Table of contents
Other Elko Timer manuals
Popular Timer manuals by other brands

Delta
Delta Digital timer User guide & warranty

Intermatic
Intermatic SS7 Series Installation and operating instructions

Full Gauge Controls
Full Gauge Controls Tempus E instruction manual

Redback
Redback A 2064 operating manual

Intermatic
Intermatic TB121C instructions

myTouchSmart