manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Elko
  6. •
  7. Timer
  8. •
  9. Elko ATS-2D User manual

Elko ATS-2D User manual

1 / 2
ATS-2D, ATS-2DR, ATS-2WR
02-6/2021 Rev.: 0
Made in Czech Republic
1
2
3
4
5
6
7
0´
13245
CNC NO M
16 (4)A 250V 230V
50/60 Hz
M
0´
ELKO EP, s.r.o.
Palackého 493
769 01 Holešov, Všetuly
Czech Republic
Tel.: +420 573 514 211
e-mail: [email protected]
www.elkoep.com
Characteristics Description
EN
Connection
1. Output contact (1-2-3)
2. Direction of rotation of the
programming dial
3. Operating mode switch
4. Supply voltage terminals (4-5)
5. Transparent opening cover
6. Time indicator
7. Sealing spot
Example: 3 = Wednesday, 2:45 p.m.
Do not turn counter clockwise
Time setting - daily program Day / time setting - weekly program
Do not turn counter clockwise
• The mechanical time switch is a simple and inexpensive alternative to digital
time switches for controlling heating, ventilation, cooling, lighting systems
or pumps depending on real time.
• Daily or weekly program
• Selection of operating modes using the switch on the panel:
switches automatically according to the set program
permanently closes
permanently opens
• Power reserve after power o for up to 150 hours after fully charged.
• Sealable transparent front panel cover.
Analog time switch
with daily/weekly program
2 / 2
ATS-2D ATS-2DR ATS-2WR
123
1
2
3
4
19
20
21
22
24
23
8
x
Warning
Device is constructed for connection in 1-phase main alternating current voltage and must be installed according to norms valid in the state of application. Connection according to the details in
this direction. Installation, connection, setting and servicing should be installed by qualied electrician sta only, who has learnt these instruction and functions of the device. This device contains
protection against overvoltage peaks and disturbancies in supply. For correct function of the protection of this device there must be suitable protections of higher degree (A, B, C) installed in front
of them. According to standards elimination of disturbancies must be ensured. Before installation the main switch must be in position “OFF” and the device should be de-energized. Don´t install
the device to sources of excessive electro-magnetic interference. By correct installation ensure ideal air circulation so in case of permanent operation and higher ambient temperature the maximal
operating temperature of the device is not exceeded. For installation and setting use screw-driver cca 2 mm. The device is fully-electronic - installation should be carried out according to this fact.
Non-problematic function depends also on the way of transportation, storing and handling. In case of any signs of destruction, deformation, non-function or missing part, don´t install and claim at
your seller it is possible to dismount the device after its lifetime, recycle, or store in protective dump.
Technical parameters
Supply
Supply terminals:
Supply voltage:
Power consumption (max.):
Supply voltage tolerance:
Time circuit
Program:
Number of switching segments:
Minimum switching interval:
Operating accuracy:
Power reserve:
Output
Number of contacts:
Rated current:
Breaking capacity:
Switching voltage:
Mechanical life:
Electrical life (AC1):
Other information
Operating temperature:
Storage temperature:
Dielectric strength:
Operating position:
Mounting:
Protection degree:
Overvoltage category:
Pollution degree:
Max. cable size
(mm2):
Dimensions:
Weight:
Standards:
4,5
AC 230V (50/60 Hz)
1W (1.5 VA)
-10%, +10%
daily daily weekly
48
1s/day
max. 150h
1x switching (AgNi)
16A/AC1
3500 VA/AC1
250 V AC
1.000.000 operations
50.000 operations
-10 to +50°C (14 to 122°F)
-10 to +50°C (14 to 122°F)
4kV (supply - output)
any
DIN rail EN 60715
IP20
III.
2
max. 1x 4, max. 2x 1.5 /
s dutinkou max. 1x 4, max. 2x 1.5 (AWG 12)
90 x 35 x 60 mm (3.5˝ x 1.4˝ x 2.4˝)
117 g (4.1 oz.)
EN 61812-1, EN 60669-1, EN 63044-1
Setting
Example:
06:00 ... 12:00 ON
12:00 ... 14:00 OFF
14:00 ... 19:30 ON
19:30 ... 06:00 OFF
= OFF
= ON
= OFF = ON
Minimum switching interval:
- daily 30 minutes (1 segment)
- weekly 210 minutes (1 segment)
High temperatures can aect the accuracy of the time switches
Lower the segments all the way down
ON
OFF
30 min 30 min 3.5 hour
Power reserve (models only ATS-2DR, ATS-2WR)
The time switch starts working approx. 5 minutes after being connected to the
power supply. After approximately 72 hours from the connection to the power
supply, the power reserve, reaches it´s complete charge of 150 hours.
1= switches automatically according to the set program
2=
3=
permanently closes
permanently opens
Operating mode
+
-

This manual suits for next models

2

Other Elko Timer manuals

Elko SHT-6G User manual

Elko

Elko SHT-6G User manual

Elko SHT-1 User manual

Elko

Elko SHT-1 User manual

Elko SHT-13 User manual

Elko

Elko SHT-13 User manual

Elko SHT-4 User manual

Elko

Elko SHT-4 User manual

Elko SHT-4 User manual

Elko

Elko SHT-4 User manual

Elko SHT-4 User manual

Elko

Elko SHT-4 User manual

Elko EKO05986 User manual

Elko

Elko EKO05986 User manual

Elko SHT-1 User manual

Elko

Elko SHT-1 User manual

Elko SHT-1 User manual

Elko

Elko SHT-1 User manual

Elko SHT-1 User manual

Elko

Elko SHT-1 User manual

Elko SHT-7 User manual

Elko

Elko SHT-7 User manual

Elko SHT-6 User manual

Elko

Elko SHT-6 User manual

Elko SHT-6 User manual

Elko

Elko SHT-6 User manual

Popular Timer manuals by other brands

Tork 701U quick start guide

Tork

Tork 701U quick start guide

Conrad 61 81 95 operating instructions

Conrad

Conrad 61 81 95 operating instructions

Intermatic DT27 instructions

Intermatic

Intermatic DT27 instructions

Traceable 99M/59S instructions

Traceable

Traceable 99M/59S instructions

Prince Castle 840-T series operating instructions

Prince Castle

Prince Castle 840-T series operating instructions

finder 12.A4 manual

finder

finder 12.A4 manual

Gira 0385 Series installation instructions

Gira

Gira 0385 Series installation instructions

Advantage Controls NanoTron Installation maintenance repair manual

Advantage Controls

Advantage Controls NanoTron Installation maintenance repair manual

Qotom QTW-01 user manual

Qotom

Qotom QTW-01 user manual

hager EG210 Instructions for use

hager

hager EG210 Instructions for use

Somogyi TD 01 manual

Somogyi

Somogyi TD 01 manual

Broan NuTone CD60W manual

Broan

Broan NuTone CD60W manual

UltraPro 45184 user manual

UltraPro

UltraPro 45184 user manual

Omron H5BR Series manual

Omron

Omron H5BR Series manual

LORUS Y704 instruction manual

LORUS

LORUS Y704 instruction manual

Sunlite t300 PROGRAMING & SAFETY INSTRUCTIONS

Sunlite

Sunlite t300 PROGRAMING & SAFETY INSTRUCTIONS

Rain Bird SST-600in Setup & operation instructions

Rain Bird

Rain Bird SST-600in Setup & operation instructions

Diivoo WT-04 user manual

Diivoo

Diivoo WT-04 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.