manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Elko
  6. •
  7. Timer
  8. •
  9. Elko SHT-1 User manual

Elko SHT-1 User manual

Auto
0 6 12 18 24
Prog Man
31 2 4 5 6 7
SHT-1, SHT-1/2,
SHT-3, SHT-3/2
cos φ ≥ 0.95 M M HAL.230V
KM M
AC12
x
DC14
x
AC1
250V / 16A
AC13
x
AC2
250V / 5A
AC14
250V / 6A
AC3
250V / 3A
AC15
250V / 6A
AC5b
1000W
DC5
24V / 2A
AC6a
x
DC12
24V / 6A
AC7b
250V / 3A
DC13
24V / 2A
02-71/2017 Rev.: 2
SHT-1/2
SHT-3/2
Un
A2 26 25 28
A1 16 15 18
Un
A2
A1 16 15 18
SHT-1
SHT-3
SHT-1
SHT-3
SHT-1/2
SHT-3/2
15 25
16
A2
A1 18 26 28
1 5
16
A2
A1 18
8
9
10
11
12
13
14
15
16
17
18
19
20
5
1
2
3
4
6
7
1/4
Made in Czech Republic
ELKO EP, s.r.o.
Palackého 493
769 01 Holešov, Všetuly
Czech Republic
Tel.: +420 573 514 211
e-mail: elko@elkoep.com
www.elkoep.com Digital time switch clock
Characteristics
Description
Symbol
Connection
Type of load
Mat. contacts AgSnO2,
contact 16A
Type of load
Mat. contacts AgSnO2,
contact 16A
AC5a
uncompensated
230V / 3A (690VA)
DC1
24V / 10A
AC5a
compensated
230V / 3A (690VA)
to max. input C=14uF
DC3
24V / 3A
EN
- Serves for controlling of various types of appliances in dependance on real time
(automation-switching of heating, pumps, ventilation etc.). Appliances can be op-
erated in concrete periodic time cycles or according a pre-set program (depends
on type, see the chart Versions of time switches).
- SHT-1, SHT-3: 1-channel version.
- SHT-1/2, SHT-3/2: 2-channel version (to each channel can be assigned an individual
program).
- Possibility to control two independent circuits.
- By SHT-3, SHT-3/2 is not possible to integrate daily and night mode on one channel.
By SHT-3/2 is possible to set a dierent mode on each channel.
- Setting of switching by:
- program (PROG) - switching according programs set in SET 1 . Possibility to set the
repeat every minute or every hour.
- random (AUTO ) - random switching in 10-120 min interval.
- permanently manualy .
- Switching modes (OUT):
- OUT ON - normal - 2 positions in memory (close /open), shortest time of closing
is 1 min.
- OUT ON - cyclic - 2 positions in memory (pulse/delay), range 1-99s.
- OUT ON - pulse - 1 position in memory, range 1-99s.
- OUT OFF - turn o the switching mode.
- Set time of pulse/delay is on one channel the same for all programs (it is not pos-
sible to set more pulses with dierent durations on one channel).
- “Holiday mode #“ - possibility to choose the period, when the device will be not
switching according a standard program and will be blocked for the pre-set time.
- 100 memory positions (by SHT-1/2 and SHT-3/2 are those 100 positions common
for both channels).
- Programming of device can be realize even under voltage and also even in back-up
mode.
- Output relays operates only under voltage.
- Automatic change-over between summer/winter time (setting is for time zone
GTM+1:00).
- Back-lighted LCD display.
- Easy and quick setting by 4 control buttons.
- Sealable transparent cover of the front panel.
- Time switch is back-up with in-built lithium element, which saves data during volt-
age failure. Back-up time reserve - up to 3 years.
- Supply voltage: AC 230V or AC/DC 12-240V.
- 2-Module, DIN rail mounting, saddle terminals.
- Device is delivered with pre-programmed actual time, which is permanently dis-
played also in back-up mode.
1. Supply voltage terminal (A1)
2. Display with back-light
3. Place for seal
4. Supply voltage terminal (A2)
5. Output - channel 1 (16-15-18)
6. Control buttons
7. Output - channel 2 (26-25-28)
8. Indicates the day in the week
9. Operating modes indication
10. Indication (1st channel)
11. Indication of time/date/setting menu
12. Bargraf
13. Control button PRG / +
14. Reset
15. Control button MAN1 / -
16. Indication (2nd channel)
17. Indicates 12 / 24 mode
18. Indicates summer / winter mode
19. Control button MAN2 / ESC
20. Control button OK
CONTROL OF A DISPLAY WITH BACKLIGHT
Display is illuminated with a back-light for
10 s from last button press.
Permanent on / o is activated by
synchronic press of buttons MAN, ESC, OK.
After permanent on/o activation, display
will ash shortly.
All manuals and user guides at all-guides.com
all-guides.com
SHT-1 SHT-3 SHT-1/2 SHT-3/2
230 UNI
0 6 12 18 24
Prog


0 6 12 18 24
0 6 12 18 24
Man
0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
















0 6 12 18 24
4
0 6 12 18 24
4


0 6 12 18 24
Man
4


0 6 12 18 24
Man
4






2/4
Technical parameters
A1 - A2
AC/DC 12-240V (AC 50-60Hz)
AC 0.5 - 2VA / DC 0.4 - 2W
AC 230V / 50 - 60Hz
AC max. 14VA / 2W
-15 %; +10 %
yes
automatic
1 x changeover (AgSnO2) 2 x changeover (AgSnO2)
16A / AC1
4000 VA / AC1, 384W / DC
30A / <3s
250V AC1 / 24V DC
> 3x107
> 0.7x105
up to 3 years
max. ±1s/ day at 23°C
1 min.
min. 10 years
1-99s
1-99s
100
daily, weekly
daily, weekly, monthly, yearly
(up to year 2095)
LCD display, with back light
-20.. +55 °C
-30.. +70 °C
4 kV (supply - output)
any
DIN rail EN 60715
IP10 clips, IP40 from front panel
III.
2
solid wire max. 2x 2.5 or 1x 4
with sleeve max. 1x 2.5 or 2x 1.5
90 x 35.6 x 64 mm
(UNI)-130 g, (230)-110 g
(UNI)-143 g, (230)-125 g
EN 61812-1, EN 61010-1
Supply terminals:
Supply voltage:
Consumption:
Supply voltage:
Consumption:
Supply voltage tolerance:
Real time back-up:
Summer/winter time:
Output:
Number of contacts:
Rated current:
Switching capacity:
Peak current:
Switching voltage:
Mechanical life:
Electrical life (AC1):
Time circuit
Real time back-up when de-
energi.:
Accuracy:
Minimum interval:
Data stored for:
Cyclic output:
Pulse output:
Program circuit
Number of memory places:
Program (SHT-1, SHT-1/2):
Program(SHT-3, SHT-3/2):
Data readout:
Other information
Operating temperature:
Storage temperature:
Electrical strength:
Operating position:
Mounting:
Protection degree:
Overvoltage category:
Pollution degree:
Max. cable size (mm2):
Dimensions:
Weight
- SHT-1, SHT-3:
- SHT-1/2, SHT-3/2:
Standards:
Versions of time switches
Type of product
output time program
1 channel 2 channels day week month year
SHT-1 zzz
SHT-1/2 zzz
SHT-3 z zzzz
SHT-3/2 zzzzz
Precendence of controlling
modes
display output mode
 ON / OFF manual control
 ON / OFF #holiday mode
 ON / OFF auto random mode for switching
 ON / OFF / pulse-cyclic mode
ON / OFF normal mode Prog
highest priority of
controlling mode
lowest priority of
controlling mode
Mode precendence
setting, adjustment and program deleting
setting of programmed /random mode
holiday mode
exit from menu
date and time setting
Control
Device diers short and long button press. In the manual marked as:
- short button press (<1s)
- long button press (>1s)
c/d- number indicates button press sequence
After 30s of inactivity (from the last press of any button) will device automatically returns into
starting menu.
- entrance into programming menu
- browsing in menu
- setting of values
- quick shifting during setting of values
- entrance into required menu
- conrmation
- entrance into chosen program (EDIT)
- one level up
- back to the starting menu
setting of pulse /cyclic mode interval
- is superior to other set modes
Manual output control
- controls channel 1
- controls channel 2
(by SHT-1/2 and SHT-3/2)
relay orelay on
Warning
Device is constructed for connection in 1-phase main alternating current voltage and must
be installed according to norms valid in the state of application. Connection according to the
details in this direction. Installation, connection, setting and servicing should be installed by
qualied electrician sta only, who has learnt these instruction and functions of the device.
This device contains protection against overvoltage peaks and disturbancies in supply. For
correct function of the protection of this device there must be suitable protections of higher
degree (A, B, C) installed in front of them. According to standards elimination of disturbancies
must be ensured. Before installation the main switch must be in position “OFF” and the device
should be de-energized. Don´t install the device to sources of excessive electro-magnetic in-
terference. By correct installation ensure ideal air circulation so in case of permanent opera-
tion and higher ambient temperature the maximal operating temperature of the device is not
exceeded. For installation and setting use screw-driver cca 2 mm. The device is fully-electronic
- installation should be carried out according to this fact. Non-problematic function depends
also on the way of transportation, storing and handling. In case of any signs of destruction,
deformation, non-function or missing part, don´t install and claim at your seller it is possible to
dismount the device after its lifetime, recycle, or store in protective dump.
All manuals and user guides at all-guides.com


0 6 12 18 24
Man
4


0 6 12 18 24
Man
4
0 6 12 18 24
Prog


0 6 12 18 24


0 6 12 18 24


06
0 6 12 18 24
d
c



0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
d
c



0 6 12 18 24
0 6 12 18 24
d
c



SET 1
0 6 12 18 24

d
c


0 6 12 18 24
Prog


0 6 12 18 24
o

c




0 6 12 18 24
406
0 6 12 18 24
d
c



0 6 12 18 24
0 6 12 18 24
d
c



0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
d
c



0 6 12 18 24
0 6 12 18 24
Prog
0 6 12 18 24
0 6 12 18 24
d
c



0 6 12 18 24
7
24
6
24
24
5
4
24
3
24
2
24
06
1
0 6 12 18 24
d
c



0 6 12 18 24
d
c



0 6 12 18 24
d
c



0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
d
c



0 6 12 18 24
0 6 12 18 24
7
24
6
24
24
5
4
24
3
24
2
24
06
1
0 6 12 18 24
d
c



0 6 12 18 24


0 6 12 18 24
Man
4
0 6 12 18 24
............


0 6 12 18 24


0 6 12 18 24

d
c


0 6 12 18 24
Prog


0 6 12 18 24
o

c


0 6 12 18 24
Man
4





0 6 12 18 24


0 6 12 18 24
4
0 6 12 18 24
Man
4


0 6 12 18 24
Man
4


0 6 12 18 24
Man
4
0 6 12 18 24
0 6 12 18 24
d
c



0 6 12 18 24
d
c



0 6 12 18 24
d
c



0 6 12 18 24
d
c



0 6 12 18 24
d
c



0 6 12 18 24
Prog



0 6 12 18 24


0 6 12 18 24
0 6 12 18 24
d
c



0 6 12 18 24
0 6 12 18 24
d
c





0 6 12 18 24
Man
4
0 6 12 18 24
Man
06 18 24
0 6 12 18 24
d
c



Auto
0 6 12 18 24
0 6 12 18 24
Prog
d
c



0 6 12 18 24
Prog





0 6 12 18 24
Man
SET 2
SET 3
3/4
Program setting
ADD - add a new
program
only by daily mode:
ON/OFF - setting
of the program
activity in concrete
day of the week
setting of hour and
minute of program
start /end *
only by yearly mode:
setting of year,
month and day
OUT - setting of
switching mode
- OUT ON - normal
- OUT ON - cyclic
- OUT ON - pulse
- OUT OFF - turn o the
switching mode
by SHT-3 and SHT-3/2
- selection of daily /
night mode
by SHT1/2 and
SHT3/2 - selection
of channel
Program adjustment
only by daily mode:
ON/OFF - selection /
adjustment of program
activity in concrete day
of the week
time adjustment
(hours / minutes)
OUT - selection /
adjustment of
switching mode
- by SHT-3 and
SHT-3/2 selection /
adjustment of set
mode
- by SHT-1/2 and
SHT-3/2 selection /
adjustment of
channel
selection /
entrance into
chosen program
EDIT - adjustment
of already saved
programs
- long press (>1s)
- short press (<1s)
c/d- press sequence
If the program memory is full, display announces it by notice FULL.
* If “- -” (2 dashes) is set as the hour or minute value instead of a numerical value, the start / end of the program will be repeated every hour or every minute.
only by yearly
mode: adjusting of
date (year, month
and day)
Program deleting Deleting of all programs
DEL - deleting of
individual programs
program selection
- long press OK - deleting of
chosen program
in starting menu (time is shown
on display) - press simultaneously
button PRG and OK and display
announces a notice ALL
press button OK to
complete the deleting of
all set programs
Date and time setting
activation of
changeover between
summer/winter time
minutes settinghour settingsetting of time in 24
or 12 hour format
day settingmonth settingyear setting
Setting of programmed / random mode
In starting mode by chosen channel ashs symbol Prog or on display (automatically preset switching according PROG).
PROG - relay is switching according
programs set in menu SET 1
AUTO - relay is switching
randomly in 10-120 min interval
by SHT-1/2 and SHT-3/2
- selection of channel
All manuals and user guides at all-guides.com


0 6 12 18 24
Man
4
0 6 12 18 240 6 12 18 24
d
c



0 6 12 18 24
d
c



0 6 12 18 24
Prog





0 6 12 18 24
06
0 6 12 18 24
d
c



0 6 12 18 24
Prog



SET 5
0 6 12 18 24
24
0 6 12 18 24
d
c



0 6 12 18 24
d
c



0 6 12 18 24
d
c



0 6 12 18 24
d
c



0 6 12 18 24
d
c



0 6 12 18 24
d
c



0 6 12 18 24
d
c





0 6 12 18 24
End
0 6 12 18 24
Prog





0 6 12 18 24 0 6 12 18 24
Man
4


0 6 12 18 24
Man
4


0 6 12 18 24
Man
4
12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24
1


0 6 12 18 24
Man
4
0 6 12 18 24
Prog


0 6 12 18 24


0 6 12 18 24


0 6 12 18 24
d
c



0 6 12 18 24
d
c



0 6 12 18 24
d
c



0 6 12 18 24


0 6 12 18 24
d
c



0 6 12 18 24
............


0 6 12 18 24
Prog


0 6 12 18 24
4
d
c



0 6 12 18 24
0 6 12 18 24
............


7
24
6
0 6 12 18 24
d
c



7
24
6
0 6 12 18 24
d
c



24
5
4
24
3
24
2
24
06
1
0 6 12 18 24


d
c



0 6 12 18 24
24
5
4
24
3
24
2
24
06
1
0 6 12 18 24


0 6 12 18 24
d
c



0 6 12 18 24
d
c



SET 4
4/4
Setting of pulse / cyclic mode interval
by SHT-1/2 and SHT-3/2
selection of channel
setting of pulse /
cycle duration
setting of delay /
cycle duration
(by - pulse mode
do not set)
Setting of time of pulse / cyclic mode switching is realized by SET 1 .
Holiday mode
In the starting mode during the activation of holiday mode, ashs symbol #on display.
holiday mode
ending day setting
holiday mode
ending month
setting
holiday mode
ending year setting
holiday mode
starting day setting
holiday mode
starting month
setting
holiday mode
starting year setting
holiday mode
setting
- return to the starting modeExit from menu
- long press (>1s)
- short press (<1s)
c/d- press sequence
Activated by, covered RESET button, short press with blunt spike (with max. 2 mm diameter).
After press, information about type of device and rmware version will displayed for 3 s and then
device performs in starting mode.
Reset will delete an actual time, set time of pulse/cyclic mode and all temporary functions (manual
or random switch output).
Reset will save all set programs.
Reset
Example of programming
Setting of SHT-3/2 to be activated from Monday till Friday at 8:00 by program 0 ( ) , and deactivated from Monday till Friday at 16:30 by program 1 ( ).
setting of switching on
program 0 channel 1 daily program turn on a
normal mode
time of
turning on
setting of activity
Mo-Fri
turning o the
activity Sat-Sun
savestarting menu programming add the program
setting of switching o
program 1 channel 1
daily program turn o a
normal mode
time of
turning o
setting of
activity Mo-Fri
turning o the
activity Sat-Sun
save return into
starting menu
All manuals and user guides at all-guides.com

Other manuals for SHT-1

7

This manual suits for next models

3

Other Elko Timer manuals

Elko SHT-4 User manual

Elko

Elko SHT-4 User manual

Elko SHT-6G User manual

Elko

Elko SHT-6G User manual

Elko SHT-1 User manual

Elko

Elko SHT-1 User manual

Elko ATS-2D User manual

Elko

Elko ATS-2D User manual

Elko SHT-1 User manual

Elko

Elko SHT-1 User manual

Elko SHT-13 User manual

Elko

Elko SHT-13 User manual

Elko SHT-1 User manual

Elko

Elko SHT-1 User manual

Elko SHT-6 User manual

Elko

Elko SHT-6 User manual

Elko SHT-7 User manual

Elko

Elko SHT-7 User manual

Elko SHT-4 User manual

Elko

Elko SHT-4 User manual

Elko EKO05986 User manual

Elko

Elko EKO05986 User manual

Elko SHT-4 User manual

Elko

Elko SHT-4 User manual

Elko SHT-6 User manual

Elko

Elko SHT-6 User manual

Popular Timer manuals by other brands

Somogyi Home 0760S instruction manual

Somogyi

Somogyi Home 0760S instruction manual

F&F AS-224 manual

F&F

F&F AS-224 manual

CEBEK I-22 quick start guide

CEBEK

CEBEK I-22 quick start guide

ADI T-Max 3W G2 user guide

ADI

ADI T-Max 3W G2 user guide

Xenios The Nano Timer user manual

Xenios

Xenios The Nano Timer user manual

axhess 2.440.007 manual

axhess

axhess 2.440.007 manual

Conrad 552443 operating instructions

Conrad

Conrad 552443 operating instructions

Siemens 7LF4 511-0 operating instructions

Siemens

Siemens 7LF4 511-0 operating instructions

Stanley TimerMax operating instructions

Stanley

Stanley TimerMax operating instructions

Meister TGE-20 operating instructions

Meister

Meister TGE-20 operating instructions

Parkside 393778 2104 Operation and safety notes

Parkside

Parkside 393778 2104 Operation and safety notes

Intermatic HB51RC supplementary guide

Intermatic

Intermatic HB51RC supplementary guide

Mitsubishi Electric PAC-SC32PTA Instruction book

Mitsubishi Electric

Mitsubishi Electric PAC-SC32PTA Instruction book

GEV LZV 6287 quick start guide

GEV

GEV LZV 6287 quick start guide

BRINKS 44-1021 manual

BRINKS

BRINKS 44-1021 manual

Bosch WT PSI 6 Series technical information

Bosch

Bosch WT PSI 6 Series technical information

Leifheit 21351 operating instructions

Leifheit

Leifheit 21351 operating instructions

Sony PT-D3 operating instructions

Sony

Sony PT-D3 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.