Make sure to connect the (longer) 2-wire cord from the power supply
unit (24V or 110/230V) in the right compartment to the power connector
(2). For more information about PSU, please see manual for CMip2110/
WZU-AC230-xx.

Remove the red flap inside the meter. If the right compartment for
power supplies is equipped, remove that battery or power supply unit.
For the meter supply, a Landis+Gyr WZU-BC+GUM battery has to be
inserted into the left compartment. Mount the Landis+Gyr WZU-NB-
IoT-BAT (battery+holder) in the right compartment. Battery operation
is available from FW 1.03. Models with earlier FW can be remotely
updated.

• The battery supplying the meter must be connected before
connecting the battery supplying the CMi6110.
• Removing the meter’s red flap is only allowed for this purpose!
• The battery holder (made of isolating material) substitutes the
function of the red flap. Once inserted into the meter it cannot be
removed.

Make sure to connect an external antenna (released by the supplier)
with MCX connector to the module in the UH50/UC50. The image
below illustrates how the antenna cable should be routed. Push the
connector gently into the socket on the module.

• The antenna should be mounted at least 0.5 meter away from the
meter to avoid interference.
• The rubber gromets may not be cut.
• Punch a small hole with 3mm diameter through the gromet.
A 3mm hex key (Allen key), for example, is a suitable tool.
• Make sure to remove the strain relief (metallic clip) and do not
remount it due to the risk of damaging the antenna cable. If
you want to add additional strain relief, mount a cable tie on the
antenna cable, close to the cable entry inside the enclosure.
MOUNTING
Before mounting the module in the meter, make sure that a SIM card is
installed in the SIM card slot (7) as illustrated below.
 

CMi6110 is mounted in module slot 2 of a Landis+Gyr UH50/UC50 with
software version 5.15/8.07 or higher. Grab the device by the outer edges
and gently press it into position.

• Electrostatic-sensitive devices. Please observe the
necessary ESD protective measures when installing
the device.

CMi6110 is an integrated meter connectivity module mounted inside
a Landis+Gyr UH50 heat meter/UC50 heat calculator to deliver
meter data to a receiving system via a NB-IoT network. For a complete
description of the product, or for information in other languages, please
visit the Elvaco AB website, https://www.elvaco.com.

 

1. Meter Interface
2. PSU Power Connector
3. Battery Power Connector*
4. Push Button
5. Antenna Connector (MCX)
6. NFC Antenna
7. SIM Card Holder
8. Green LED
9. Red LED
*Option
SIM

 


 

© 2020, Elvaco AB. All rights reserved. The documentation and product are provided on an “as is” basis only and may contain deciencies or in-
adequacies. Elvaco AB takes no responsibility for damages, liabilities or other losses by using this product. No part of the contents of this manual
may be transmitted or reproduced in any form by any means without the written permission of Elvaco AB. Printed in Sweden.
CMi6110 Quick manual English
Version: 1.8.1

The warranty does not cover damage to the product caused by usage in
any other way than described in this manual. Elvaco AB can not be liable
for personal injury or property damage caused by usage in any other way
than described in this manual.

Upon delivery, CMi6110 has a standard conguration. If you would like
to change conguration, please download the Elvaco OTC Application
(One-Touch commissioning) for Android, available in Google Play store.
The Elvaco OTC connects to the module via NFC.
By default, the product is set to passive mode, which means no
messages will be transmitted from the device. There are two ways to
activate the product:
1. Press and hold down the push button (4) for at least 5 seconds until
the green LED (8) lights up.
2. Read the meter via NFC to activate the Apply tab in the Elvaco
OTC app. Go to the Apply tab, set the Power mode to “Active”, push
“Apply” and place the phone on the right side of the meter, next
to the module. Make sure to hold the phone still until the phone
vibrates.
Upon start-up, the module will attempt to connect to the mobile
network. The phase is indicated by short flashes on the green LED.
After successfully connecting to the mobile network, the green LED will
lighten up for 8 seconds, as indicated by the gure below.

• Make sure to locate the NFC antenna on your phone. When you
scan or write new congurations to the module, you should place
the phone’s NFC antenna as close as possible to the NFC antenna
of the module (6). The best place is on the right side of the meter.


Dimensions (w x h x d) 84 x 37 x 12 mm
Mounting In Landis+Gyr UH50/UC50 module slot 2
External antenna
connector
MCX female
SIM card Slide, size Nano

Mains supply 
CMip2110

WZU-AC230-xx
24 V supply 
CMip2110

WZU-ACDC24-00
Battery supply 
Landis+Gyr battery+holder: WZU-NB-
IoT-BAT

Landis+Gyr: WZU-BC+GUM
Battery life time 7+1 year
The battery life time is based on ECL0 and
hourly reading sent once / day.

Nominal voltage PSU 100-230 VAC / 24VAC
Nominal voltage Battery 3 VDC
Current consumption
(max)
400 mA
Current consumption
(sleep mode)
6µA

Operating temperature +5 °C to +55 °C
Operating humidity 0 - 93 % RH, no condensation
Operating altitude 2000 m
Pollution degree Degree 1
Usage environment Indoors
Storage temperature -20 °C to +60 °C (Module)

Band 20, 8, 3
3GPP Release 14 (NB2)
Transmit power Maximum 23.0 dBm
Receiver sensitivity -135 dBm

Green LED Start-up, Network connection
Red LED Start-up, Error
Push button Start-up, Reboot
Conguration • NFC via Elvaco OTC App
• Via LwM2M (Elvaco Evo DM-system, or
third-party DM-system)
• Precong on delivery


Phone: +46 300 434300
E-mail: [email protected]
Online: www.elvaco.com

Other manuals for CMi6110

4

Other Elvaco Measuring Instrument manuals

Elvaco CMeX20w User manual

Elvaco

Elvaco CMeX20w User manual

Elvaco CMi4170 User manual

Elvaco

Elvaco CMi4170 User manual

Elvaco CMi6140 User manual

Elvaco

Elvaco CMi6140 User manual

Elvaco CMeX10S Installation guide

Elvaco

Elvaco CMeX10S Installation guide

Elvaco CMi4110 User manual

Elvaco

Elvaco CMi4110 User manual

Elvaco CMi4130 User manual

Elvaco

Elvaco CMi4130 User manual

Elvaco CMe3100 User manual

Elvaco

Elvaco CMe3100 User manual

Elvaco CMi6110 User manual

Elvaco

Elvaco CMi6110 User manual

Elvaco CMi4110 User manual

Elvaco

Elvaco CMi4110 User manual

Elvaco CMe2100 Installation guide

Elvaco

Elvaco CMe2100 Installation guide

Elvaco CMi6140 User manual

Elvaco

Elvaco CMi6140 User manual

Elvaco CMi4170 User manual

Elvaco

Elvaco CMi4170 User manual

Elvaco CMe2100 gen.3 User manual

Elvaco

Elvaco CMe2100 gen.3 User manual

Elvaco CMi4170 User manual

Elvaco

Elvaco CMi4170 User manual

Elvaco CMi6140 User manual

Elvaco

Elvaco CMi6140 User manual

Popular Measuring Instrument manuals by other brands

Nivel System CL3D user manual

Nivel System

Nivel System CL3D user manual

OptoTest OP415 instruction manual

OptoTest

OptoTest OP415 instruction manual

Sensit CO quick start guide

Sensit

Sensit CO quick start guide

Addi-Data MSX-E3711 Quick installation

Addi-Data

Addi-Data MSX-E3711 Quick installation

TUF HD 80 G operating manual

TUF

TUF HD 80 G operating manual

FLIR EXTECH HDV-WTX1 Informational sheet

FLIR

FLIR EXTECH HDV-WTX1 Informational sheet

Datum Systems VoidMate installation guide

Datum Systems

Datum Systems VoidMate installation guide

Seca 287 Instruction manual and guarantee

Seca

Seca 287 Instruction manual and guarantee

Landis+Gyr T450 Service manual

Landis+Gyr

Landis+Gyr T450 Service manual

Precision Digital Corporation Helios PD2-6300 instruction manual

Precision Digital Corporation

Precision Digital Corporation Helios PD2-6300 instruction manual

Spectrum FIELDSCOUT TDR 100 product manual

Spectrum

Spectrum FIELDSCOUT TDR 100 product manual

Schmidt MST Series instruction manual

Schmidt

Schmidt MST Series instruction manual

Autonics MP5S Series instruction manual

Autonics

Autonics MP5S Series instruction manual

HODAKA HT-1200N operating manual

HODAKA

HODAKA HT-1200N operating manual

MONARCH INSTRUMENT Pocket Tach 99 instruction manual

MONARCH INSTRUMENT

MONARCH INSTRUMENT Pocket Tach 99 instruction manual

Hach TitraLab Basic user manual

Hach

Hach TitraLab Basic user manual

AEMC 6255 user manual

AEMC

AEMC 6255 user manual

SensaTronics U Device manual

SensaTronics

SensaTronics U Device manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.