manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emerson
  6. •
  7. Control Unit
  8. •
  9. Emerson Keystone 952 User manual

Emerson Keystone 952 User manual

Other Emerson Control Unit manuals

Emerson Fisher Baumann 24000F User manual

Emerson

Emerson Fisher Baumann 24000F User manual

Emerson numatics E22 User manual

Emerson

Emerson numatics E22 User manual

Emerson CV4-7 Series User manual

Emerson

Emerson CV4-7 Series User manual

Emerson Fisher N100 Series User manual

Emerson

Emerson Fisher N100 Series User manual

Emerson 850 User manual

Emerson

Emerson 850 User manual

Emerson Asco Bio-Pure User manual

Emerson

Emerson Asco Bio-Pure User manual

Emerson Fisher 1808 User manual

Emerson

Emerson Fisher 1808 User manual

Emerson Spence K5 User manual

Emerson

Emerson Spence K5 User manual

Emerson BM6X Series User manual

Emerson

Emerson BM6X Series User manual

Emerson Copeland 3290262 Manual

Emerson

Emerson Copeland 3290262 Manual

Emerson SW46 User manual

Emerson

Emerson SW46 User manual

Emerson Crosby JOS-E Series User manual

Emerson

Emerson Crosby JOS-E Series User manual

Emerson Rosemount 68 Series User manual

Emerson

Emerson Rosemount 68 Series User manual

Emerson Fisher TBX User manual

Emerson

Emerson Fisher TBX User manual

Emerson Fisher A11 User manual

Emerson

Emerson Fisher A11 User manual

Emerson Sempell series User manual

Emerson

Emerson Sempell series User manual

Emerson RAIMONDI User manual

Emerson

Emerson RAIMONDI User manual

Emerson PACSystems IC695ACC302 User manual

Emerson

Emerson PACSystems IC695ACC302 User manual

Emerson FISHER CV500 User manual

Emerson

Emerson FISHER CV500 User manual

Emerson Daniel 762 User manual

Emerson

Emerson Daniel 762 User manual

Emerson ES-805 Series User manual

Emerson

Emerson ES-805 Series User manual

Emerson Tescom ER5K User manual

Emerson

Emerson Tescom ER5K User manual

Emerson TopWorx PD200 Instruction manual

Emerson

Emerson TopWorx PD200 Instruction manual

Emerson C471 User manual

Emerson

Emerson C471 User manual

Popular Control Unit manuals by other brands

Festo Compact Performance CP-FB6-E Brief description

Festo

Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

Elo TouchSystems

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation MPC3034A user manual

JS Automation

JS Automation MPC3034A user manual

JAUDT SW GII 6406 Series Translation of the original operating instructions

JAUDT

JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum Air Module System manual

Spektrum

Spektrum Air Module System manual

BOC Edwards Q Series instruction manual

BOC Edwards

BOC Edwards Q Series instruction manual

KHADAS BT Magic quick start

KHADAS

KHADAS BT Magic quick start

Etherma eNEXHO-IL Assembly and operating instructions

Etherma

Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations Attenuverter Assembly guide

PMFoundations

PMFoundations Attenuverter Assembly guide

GEA VARIVENT Operating	 instruction

GEA

GEA VARIVENT Operating instruction

Walther Systemtechnik VMS-05 Assembly instructions

Walther Systemtechnik

Walther Systemtechnik VMS-05 Assembly instructions

Altronix LINQ8PD Installation and programming manual

Altronix

Altronix LINQ8PD Installation and programming manual

Eaton Powerware Series user guide

Eaton

Eaton Powerware Series user guide

WAGO 750-407/040-000 manual

WAGO

WAGO 750-407/040-000 manual

Sony CCU-590 Operation manual

Sony

Sony CCU-590 Operation manual

Graco 25D614 instructions

Graco

Graco 25D614 instructions

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Task Force Tips

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Shini SPV-U Series manual

Shini

Shini SPV-U Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

7
6
12
10
2
9
20
21
5
8
14
16
4
13
1
3
11
19
17
18
15
KEYSTONE FIGURE 952 KNIFE GATE VALVES
INSTALLATION AND OPERATING MANUAL
© 2017 Emerson. All Rights Reserved.
Gland packing replacement instructions for DN 50 - 200 (NPS 2 - 8)
Figure 952 knife gate valves
PACKING REPLACEMENT
For optimum performance, the packing
material should be replaced whenever the
valve has been disassembled for routine
maintenance. This is a very simple procedure
which can be done leaving the valve in the
pipeline.
Correct packing is essential for leak-free
operation. Use Emerson’s preformed and pre-
cut packing replacement kits for best results.
Kits are available in the following types:
K-LON - Standard packing material.
D-LON - Food grade packing.
G-LON - High cyclic packing.
H-LON - Abrasive service packing.
Ensure packing material selected is suitable
forthe service.
DISASSEMBLY PROCEDURE
1. Ensure the pipeline is not pressurized and
any hazardous medium is drained away.
2. Close valve. Loosen gland box nuts (10)
toend of pillar (9) threads.
3. Remove clevis fastener (19).
4. Remove both bridge bolts (14).
5. Remove bridge sub-assembly (handwheel,
handwheel nut, spindle and bridge or
cylinder actuator and bridge).
NOTE
Heavy valves will require a chain block or crane to
assist.
6. Unscrew both pillars (9).
7. Unscrew gate guides approximately 2 turns
(Not applicable on polyurethane trim valves).
8. Withdraw gland box (3) and gate (2)
sub-assembly.
9. Remove scraper (7) (Not fitted on
polyurethane trim valves) and packing
segments (6) from the gland box (3), noting
the number of layers.
10. Clean gland box (3) and gate (2). Check gate
for irregularities or abrasion on the seating
side. If excessive, discard and replace.
Note: DN 50 - 200 (NPS 2 - 8) valve illustrated.
Emerson.com/FinalControl VCIOM-02046-EN 18/07
PACKING PROCEDURE
NOTE
Care should be taken to stagger the mitred joints
in each layer of packing to the opposite side of the
glandbox, e.g.;
• 1st packing layer joint to the front of the valve
• 2nd packing layer joint to the rear of the valve
• (on larger valves) 3rd packing layer joint to the front
of the valve.
1. Press first layer of gland packing (6) into
gland box (3) cavity by hand, then repeat
the process with the second layer ensuring
the joints of the two layers are on opposing
sides of the cavity
2. Push gate (2) (rounded edge first) gently
through top of gland box with packing
underneath, then turn upside down and
push gland box to 25 mm (1") from the
end of the gate. Firmly press packing in
with fingers around gate then fit the RTFE
scraper blade (7) (Not fitted on polyurethane
trim valves) in bottom of gland box.
2
7
6
12
10
2
9
20
21
5
8
14
16
4
13
1
3
11
19
17
18
15
KEYSTONE FIGURE 952 KNIFE GATE VALVES
INSTALLATION AND OPERATING MANUAL
ASSEMBLY PROCEDURE
1. With bevelled edge (Not applicable on
polyurethane trim valves) of gate up stream
and away from the seating face, place gland
box/gate sub-assembly into body and push
gate down until firmly wedged at bottom of
valve.
2.
Screw the gland box nuts (10) onto each
pillar (9), add washers (11) and (12). Coat
threads with anti-seize compound. Put each
pillar sub-assembly through gland box holes
and screw them into the valve body lug until
pillar is level with the bottom of the body lug.
Height of pillars (9) should be equal.
NOTE
For Polyurethane trimed valves ignore steps
3through5.
3. Screw in the gate guides (13) until they
contact the gate, do not over tighten.
4. With gate firmly wedged into bottom of
valve, push top of gate towards downstream
side to ensure it’s firmly up against seat (4),
thentighten pillar nuts.
5. Check gate alignment (gate closed).
If correctly fitted and aligned
• Gate will be fitting firmly and evenly up
against seating face in valve body.
• Gate and gland box will be approximately
centred with the valve body viewed from
frontand sides.
• Gate will be true and parallel to valve body
axis viewed from the side.
• Gate will not have significant movement
when rocked backwards and forwards
(upstreamand downstream, not sideways).
Note: DN 50 - 200 (NPS 2 - 8) valve illustrated.
If not fitted correctly
• Gate is not seating properly into the wedges
in the base of the valve and/or the gate guides
in the upper body of the valve are badly worn,
missing or incorrectly adjusted - repair as
necessary.
6.
Fit bridge sub-assembly (handwheel,
handwheel nut, spindle and bridge or
cylinder actuator and bridge) to the top of the
pillars and secure using bridge bolts (14).
7. To fit the clevis pin (19) adjust the spindle (5)
until the holes in the spindle and the gate
are aligned.
8. Assembly is complete, actuate to check all
is functioning as desired and gate reseats
itself into the wedges at bottom of the valve
body. If re-seating does not occur, loosen
gland box nuts (8) and remove gland box,
clean and repeat steps.
NOTE
1. At commissioning or plant start-up, open
and close valve to check it is operating
correctly - gland nuts (8) may require adjustment.
Pleaseensure to tighten equally.
2. To minimize risk to personnel, Emerson
recommend the use of purpose built guards
and shrouds. Refer to the Emerson data sheet
orconsult factory for details.
CAUTION
Do NOT over tighten gland packing as it will cause
excessive resistance to gate movement.
Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product.
Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Keystone is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson
and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be
construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by
our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without
notice.
Emerson.com/FinalControl