KEYSTONE OPERATING AND SAFETY INSTRUCTIONS
PED - RESILIENT SEATED BUTTERFLY VALVES F320/322
Please read these instructions carefully.
HAZARD POTENTIALS
• Disregarding of instructions
• Improper use of product
• Insufficiently qualified personnel
PRECAUTIONS
WARNING
For safety reasons, it is important to take the
following precautions before you start work on
the valve:
1.
Personnel making any adjustments to the valves
should utilize suitable equipment. All required
personal protection means should be worn.
2.
The line must be depressurized before installing
the valve. In case of dangerous pipeline fluids,
the pipeline should be drained and flushed
properly with an appropriate cleaning fluid.
3. Personnel trained in all aspects of manual and
mechanical handling techniques must carry
out handling of all valves.
4. Misuse of the valve is not allowed.
For example: the valve, handles, actuators or
other parts may not be used as ‘climbing tools’.
5. Ensure the valve pressure/temperature
specification as indicated on the identification
label, is within the pressure/temperature
limits of the application. A full pressure/
temperature diagram can be obtained from
the Product Manual. With the use of the figure
and trim number on the valve’s identification
label, the correct diagram can be found.
6. Ensure that valve materials are compatible
with the pipeline fluid.
7. The body material is ductile iron, which is a
known brittle material and heavy impacts such
as blows with a steel headed hammer should
be avoided. This is particularly important for
applications between 0 °C and -28 °C.
8.
The normal shelf life of the F320/322 valve
seat is 5 years under clean, dry ambient and
conditions with UV exposure prior to installation.
9. Tighten all flange bolts as per the nominated
flange standards using the diagonal sequence
method.
Before installation, these instructions must be fully read and understood
Product designation
Max. permissible working pressure
Explosive equipment classification
Nominal
diameter
Trim number
Body material
Min/Max
temperature
limits in °C
Mass
Year of construction
Identification number of
notified body
TAGPLATE - for NBR seated valves
TAGPLATE - for EPDM seated valves
© 2017 Emerson. All Rights Reserved.Emerson.com/FinalControl VCOSI-00771-EN 19/06
Ensure that valve materials are compatible with
the pipeline fluid.
Valve application to be within the pressure/
temperature limits indicated in the P/T diagram
of the Product Manual.
If in doubt contact factory.
Check the valve’s functionality on a regular basis.
2
INSTALLATION
1. Handling and lifting should be performed
according the Maintenance and Installation
Instructions.
2. Keystone valves are bi-directional unless
fitted with a Flow Direction Arrow.
If a directional arrow is fitted then the valve
must be installed with the arrow pointing in
the direction of the flow.
3. For detailed installation instructions
refer to the Maintenance and Installation
Instructions for the specific product.
4. Preferred installation position of butterfly
valves is the shaft horizontal and the lower
disc-edge opening downstream.
5. Do not use the valve to spread the flanges.
6. Instructions whether to use or to omit flange
gaskets are stated in the Maintenance and
Installation Instructions.
7. In case the valve is used as spool piece
during erection of piping, do not finish weld
the flanges to the pipes with the valve bolted
between the flanges as this will result in
serious heat-damage to the seat.
8. Valve operation should be checked for
open - close positions. The disc should have
enough clearance from the pipeline in all
positions.
MAINTENANCE
!! Read all warning labels fitted to the valve
before operation or maintenance !!
Check the valve’s functionality on a regular
basis.
No additional routine maintenance is required.
REPAIR
WARNING
The line must be depressurized before carrying
out any repairs to the valve. In case of dangerous
pipeline fluids, the pipeline should be drained and
flushed with an appropriate cleaning fluid. Failure
to do so may cause serious personal injury and/
or equipment damage. Before disassembling the
valve ensure the valve has been decontaminated
correctly from any harmful gasses or liquids
and that it is within a safe temperature range for
handling. Personnel making any adjustments
to the valves should utilize suitable equipment.
All required personal protection means should
be worn. Only qualified personnel trained in all
aspects of manual and mechanical handling
techniques must carry out lifting and handling of
valves.
Use Keystone original spare parts only.
For detailed information on valve (dis)assembly
and part replacement, refer to the Maintenance
and Installation Instructions.
KEYSTONE OPERATING AND SAFETY INSTRUCTIONS
PED - RESILIENT SEATED BUTTERFLY VALVES F320/322
Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product.
Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Keystone is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions,
Emerson and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed
as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and
conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.
Emerson.com/FinalControl

This manual suits for next models

1

Other Emerson Control Unit manuals

Emerson Keystone OM3 - EPI2 User manual

Emerson

Emerson Keystone OM3 - EPI2 User manual

Emerson PACSystems RX3i IEC 61850 User manual

Emerson

Emerson PACSystems RX3i IEC 61850 User manual

Emerson Spence Type N6 User manual

Emerson

Emerson Spence Type N6 User manual

Emerson EX4 User manual

Emerson

Emerson EX4 User manual

Emerson Micro Motion User manual

Emerson

Emerson Micro Motion User manual

Emerson Fisher EAD User manual

Emerson

Emerson Fisher EAD User manual

Emerson Fisher 8532 User manual

Emerson

Emerson Fisher 8532 User manual

Emerson MVME7616E Quick start guide

Emerson

Emerson MVME7616E Quick start guide

Emerson Fisher 92B User manual

Emerson

Emerson Fisher 92B User manual

Emerson VAREC 3600B Series Operation and maintenance manual

Emerson

Emerson VAREC 3600B Series Operation and maintenance manual

Emerson Daniel 762 User manual

Emerson

Emerson Daniel 762 User manual

Emerson AVENTICS NL1 User manual

Emerson

Emerson AVENTICS NL1 User manual

Emerson Fisher GX User manual

Emerson

Emerson Fisher GX User manual

Emerson Fisher EZ-C User manual

Emerson

Emerson Fisher EZ-C User manual

Emerson Fisher G101 Series User manual

Emerson

Emerson Fisher G101 Series User manual

Emerson ASCO 353 Series User manual

Emerson

Emerson ASCO 353 Series User manual

Emerson ANDERSON GREENWOOD 9300H User manual

Emerson

Emerson ANDERSON GREENWOOD 9300H User manual

Emerson Clarkson series User manual

Emerson

Emerson Clarkson series User manual

Emerson Fisher GX User manual

Emerson

Emerson Fisher GX User manual

Emerson COM Express Carrier Guide

Emerson

Emerson COM Express Carrier Guide

Emerson Bettis Q series User manual

Emerson

Emerson Bettis Q series User manual

Emerson YARWA 151 Series User manual

Emerson

Emerson YARWA 151 Series User manual

Emerson Fisher GX User manual

Emerson

Emerson Fisher GX User manual

Emerson ALCO Thermo TX6 User manual

Emerson

Emerson ALCO Thermo TX6 User manual

Popular Control Unit manuals by other brands

RAK WisDuo Series manual

RAK

RAK WisDuo Series manual

Siemens LMO14 Series manual

Siemens

Siemens LMO14 Series manual

Sharp NU-JC400B installation manual

Sharp

Sharp NU-JC400B installation manual

FlexiForce ForceIQ Series manual

FlexiForce

FlexiForce ForceIQ Series manual

Bibliotheca smartShelf BLD000010-000 user manual

Bibliotheca

Bibliotheca smartShelf BLD000010-000 user manual

Mitsumi WML-30 Series user manual

Mitsumi

Mitsumi WML-30 Series user manual

GHI electronics EMX user manual

GHI electronics

GHI electronics EMX user manual

Overkiz HATTARA DIN RAIL MR-ENO manual

Overkiz

Overkiz HATTARA DIN RAIL MR-ENO manual

Panasonic SF-C21 instruction manual

Panasonic

Panasonic SF-C21 instruction manual

Kohler GM77177-KP1-QS installation instructions

Kohler

Kohler GM77177-KP1-QS installation instructions

EOS EMOTEC L 09 Relay Assembly and operating instructions

EOS

EOS EMOTEC L 09 Relay Assembly and operating instructions

Quectel M80 user guide

Quectel

Quectel M80 user guide

moon MC824H Instructions and warnings for installation and use

moon

moon MC824H Instructions and warnings for installation and use

Sony DNUR-SY3 user manual

Sony

Sony DNUR-SY3 user manual

YOKOGAWA FN310 user manual

YOKOGAWA

YOKOGAWA FN310 user manual

Arbor Technology EmQ-i2200 Quick installation guide

Arbor Technology

Arbor Technology EmQ-i2200 Quick installation guide

Clearfield Clearview xPAK installation manual

Clearfield

Clearfield Clearview xPAK installation manual

EOS SBM App Module Setup and operation

EOS

EOS SBM App Module Setup and operation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.