manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emerson
  6. •
  7. Control Unit
  8. •
  9. Emerson Keystone PED Winn Hiseal Quick guide

Emerson Keystone PED Winn Hiseal Quick guide

Other Emerson Control Unit manuals

Emerson Keystone PED Quick guide

Emerson

Emerson Keystone PED Quick guide

Emerson Anderson Greenwood Quick start guide

Emerson

Emerson Anderson Greenwood Quick start guide

Emerson Anderson Greenwood 400 Series Quick guide

Emerson

Emerson Anderson Greenwood 400 Series Quick guide

Emerson Bettis Q series User manual

Emerson

Emerson Bettis Q series User manual

Emerson Fisher TBX User manual

Emerson

Emerson Fisher TBX User manual

Emerson SM-EZMotion Module P/N 400361-00 User manual

Emerson

Emerson SM-EZMotion Module P/N 400361-00 User manual

Emerson KTM Series User manual

Emerson

Emerson KTM Series User manual

Emerson FM-3 User manual

Emerson

Emerson FM-3 User manual

Emerson PACSystems RX3i User manual

Emerson

Emerson PACSystems RX3i User manual

Emerson FASANI User manual

Emerson

Emerson FASANI User manual

Emerson SEMPELL User manual

Emerson

Emerson SEMPELL User manual

Emerson Keystone Figure 969 Hopper User manual

Emerson

Emerson Keystone Figure 969 Hopper User manual

Emerson ANDERSON GREENWOOD PILOT 9300 Series User manual

Emerson

Emerson ANDERSON GREENWOOD PILOT 9300 Series User manual

Emerson 581 Series Installation instructions

Emerson

Emerson 581 Series Installation instructions

Emerson Mobrey MCU900 Series Installation instructions

Emerson

Emerson Mobrey MCU900 Series Installation instructions

Emerson ANDERSON GREENWOOD 5910C User manual

Emerson

Emerson ANDERSON GREENWOOD 5910C User manual

Emerson Anderson Greenwood 81P Technical specifications

Emerson

Emerson Anderson Greenwood 81P Technical specifications

Emerson Fisher EZL Series User manual

Emerson

Emerson Fisher EZL Series User manual

Emerson PACSystems VersaMax IC200CMM020 User manual

Emerson

Emerson PACSystems VersaMax IC200CMM020 User manual

Emerson XJ200 User manual

Emerson

Emerson XJ200 User manual

Emerson SEMPELL Quick guide

Emerson

Emerson SEMPELL Quick guide

Emerson Fisher 161 Series User manual

Emerson

Emerson Fisher 161 Series User manual

Emerson Fisher Baumann 24000F User manual

Emerson

Emerson Fisher Baumann 24000F User manual

Emerson Fisher EZ easy-e User manual

Emerson

Emerson Fisher EZ easy-e User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

KEYSTONE PED - OPERATING AND SAFETY INSTRUCTIONS
HigH Performance Butterfly ValVes (model Winn Hiseal)
© 2017 Emerson. All rights reserved.
STORAGE/PROTECTION/SELECTION
Storage
When valves are to be stored for some time
before being fitted, storage should be in
theoriginal delivery crates with any waterproof
lining and/or desiccant remaining in place.
Storage should be off the ground in a clean, dry,
indoor area. If storage is for a period exceeding
six months the desiccant bags (if supplied)
should be changed at this interval.
Protection
Valves are delivered with protection according to
customer’s specification, or in accordance with
the Quality Assurance Manual, to protect the
valve seats and closure member from damage.
Wrapping and/or covers should be left in place
until immediately before fitting to the pipe.
Selection
Ensure the valve’s materials of construction
and pressure/temperature limits shown on
the identification plate are suitable for the
process fluid and conditions. If in doubt contact
themanufacturer.
INSTALLATION
WARNING
For safety reasons, it is important to take
thefollowing precautions before you start work on
the valve:
1. Personnel making any adjustments to the
valves should utilize equipment and clothing
normally used to work with the process where
the valve is installed.
2. The line must be depressurized, drained and
vented before installing the valve.
3. Handling and Installation of all valves,
operators and actuators must be carried
out by personnel trained in all aspects of
installation and manual/mechanical handling
techniques.
4. Ensure the valve pressure/temperature
limitations marked on the identification label
are above or equal to service conditions.
Before installation these instructions must be fully read and understood
Installation
1. On-off valves are bi-directional as standard,
unless otherwise stated, and may be fitted
in either direction.
2. Installation may be carried out with stem
displaced through any angle permitted by
the bolting.
3. Spread the flanges to fit the valve easily
(donot use the valve as a crow bar).
4. Remove protective covers from valve faces.
5. Ensure that mating flanges and gaskets are
clean and undamaged.
6. Should there be any possibility of abrasive
particles (weld slag, sand etc.) within the
piping system, this could damage valve
seating areas. The system will need to be
flushed clean.
7. Ensure mating pipe flanges are aligned
correctly, bolting should be easily inserted
through mating flange holes.
8. Fit the valve into pipework ensuring easy
access of the lever/handwheel.
9. Tighten the flange bolts in a diagonal
pattern.
CE Mark in accordance with P.E.D. requirements
Valve identification
code (VIC)
Valve model/size
Works order
number
ASME/ANSI B16.34
Emerson.com/FinalControl VCOSI-01734-EN 18/01
2
!! Read all warning labels fitted to the valve
before operation or maintenance !!
OPERATION AND ROUTINE MAINTENANCE
Scope
These instructions relate to manual and
actuated valves. For special service designs,
typically cryogenic and fugitive emissions see
separate instructions.
Operation
All standard manually operated valves are
‘clockwise to close’. The closed position is
indicated by either the handlever or indicator
arrow being at 90° to the pipe/valve bore axis.
Routine maintenance
No routine maintenance is required other
than periodic inspection to ensure satisfactory
operation and sealing.
Any sign of leakage from the gland packing
should be addressed immediately by
depressurizing the valve and tightening
thegland screws gradually and evenly. If no
further adjustment is possible, or if seat or joint
leakage is suspected, the valve will require a
complete overhaul. This should be carried out
after depressurization and in accordance with
specific maintenance Instructions. Only original
spares should be used.
Spare parts
Valves are identified by a code, which is
stamped on the identification plate, located on
the valve neck. This reference should be quoted
in respect of any after sales queries, spare
parts or repair enquiries/orders.
KEYSTONE PED - OPERATING AND SAFETY INSTRUCTIONS
HigH Performance Butterfly ValVes (model Winn Hiseal)
Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product.
Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Keystone is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson
and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be
construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by
our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without
notice.
Emerson.com/FinalControl