manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emerson
  6. •
  7. Surge Protector
  8. •
  9. Emerson PowerSure Panel TVSS User manual

Emerson PowerSure Panel TVSS User manual

This manual suits for next models

1

Other Emerson Surge Protector manuals

Emerson SOLAHD STV100K Series User manual

Emerson

Emerson SOLAHD STV100K Series User manual

Emerson Sola HD STV200K Series User manual

Emerson

Emerson Sola HD STV200K Series User manual

Emerson SOLAHD STCPOE65FF User manual

Emerson

Emerson SOLAHD STCPOE65FF User manual

Emerson Liebert Surge and Signal Protection User manual

Emerson

Emerson Liebert Surge and Signal Protection User manual

Emerson PowerSure 350-500VA User manual

Emerson

Emerson PowerSure 350-500VA User manual

Emerson SolaHD STC-642 Series User manual

Emerson

Emerson SolaHD STC-642 Series User manual

Emerson Liebert TYPE SS User manual

Emerson

Emerson Liebert TYPE SS User manual

Emerson Liebert XDF User manual

Emerson

Emerson Liebert XDF User manual

Emerson Liebert PSS NET 1080T User manual

Emerson

Emerson Liebert PSS NET 1080T User manual

Emerson Interceptor II TVSS User manual

Emerson

Emerson Interceptor II TVSS User manual

Emerson Liebert LM Series User manual

Emerson

Emerson Liebert LM Series User manual

Emerson PSS Surge Protector User manual

Emerson

Emerson PSS Surge Protector User manual

Emerson SolaHD STC-HSP Series User manual

Emerson

Emerson SolaHD STC-HSP Series User manual

Emerson IE Series User manual

Emerson

Emerson IE Series User manual

Emerson AccuVar NEMA 4X User manual

Emerson

Emerson AccuVar NEMA 4X User manual

Emerson SP-6TVN User manual

Emerson

Emerson SP-6TVN User manual

Emerson PanelGuard 65 User manual

Emerson

Emerson PanelGuard 65 User manual

Emerson PowerSure PST User manual

Emerson

Emerson PowerSure PST User manual

Emerson Islatrol RM-115-10R User manual

Emerson

Emerson Islatrol RM-115-10R User manual

Emerson SolaHD SPD200K Series User manual

Emerson

Emerson SolaHD SPD200K Series User manual

Emerson SOLAHD STCCAT6P0EI User manual

Emerson

Emerson SOLAHD STCCAT6P0EI User manual

Emerson SolaHD STC-DRS Series User manual

Emerson

Emerson SolaHD STC-DRS Series User manual

Emerson AccuGuide ACGY1110808 User manual

Emerson

Emerson AccuGuide ACGY1110808 User manual

Emerson STC-SLAC Series User manual

Emerson

Emerson STC-SLAC Series User manual

Popular Surge Protector manuals by other brands

Philips Theatre Director SPP4200WA/17 Owner's manual & warranty

Philips

Philips Theatre Director SPP4200WA/17 Owner's manual & warranty

M-system MMA instruction manual

M-system

M-system MMA instruction manual

CyberPower CSP600WSU user manual

CyberPower

CyberPower CSP600WSU user manual

UTP BALUN SP-VD08 user manual

UTP BALUN

UTP BALUN SP-VD08 user manual

ELAC ProteK PR91-W Setup guide

ELAC

ELAC ProteK PR91-W Setup guide

Tsubaki TSM4000M1 instruction manual

Tsubaki

Tsubaki TSM4000M1 instruction manual

CyberPower B1006T user manual

CyberPower

CyberPower B1006T user manual

QVS PP134C Specification sheet

QVS

QVS PP134C Specification sheet

Davis Instruments Radio Surge Protector user guide

Davis Instruments

Davis Instruments Radio Surge Protector user guide

CyberPower B300WRC1 user manual

CyberPower

CyberPower B300WRC1 user manual

M-system MGD-24 instruction manual

M-system

M-system MGD-24 instruction manual

Panamax MAX 5400-EX owner's guide

Panamax

Panamax MAX 5400-EX owner's guide

OBO Bettermann ÜSM-20-230I1PE65 installation instructions

OBO Bettermann

OBO Bettermann ÜSM-20-230I1PE65 installation instructions

CyberPower CSP604T user manual

CyberPower

CyberPower CSP604T user manual

CyberPower CSP706T user manual

CyberPower

CyberPower CSP706T user manual

Mitsubishi Electric LITOL LTM-125RF manual

Mitsubishi Electric

Mitsubishi Electric LITOL LTM-125RF manual

Intermatic PS3000 installation instructions

Intermatic

Intermatic PS3000 installation instructions

Siemens SICROWBAR 7VV3003 operating instructions

Siemens

Siemens SICROWBAR 7VV3003 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Surge Protection
For Business-Critical Continuity™
Liebert PowerSure®Panel
Low Exposure — Designed for use
on branch panels or equipment in
low exposure locations. Available
up to 100kA/phase surge current
capacity. LED status indication and
Form C contacts for remote
indication are standard.
Liebert PowerSure®Panel
Medium Exposure — Offers
protection from transients on
distribution panels or any medium
exposure location.
Available in 100kA/phase and
160kA/phase, all mode and two
mode protection, small footprints,
NEMA 12 enclosure, silver link
fusing with thermal protection, all
voltage and phase configurations,
5-year warranty.
Surge Suppression Solutions For Distribution Panels
Liebert®PowerSure®Panel TVSS
Electric power line disturbances such as
high voltage transients can disrupt or
damage sensitive electronic equipment —
causing a major loss in productivity and
money. Liebert understands this problem
and offers the Liebert PowerSure®Panel
Low and Medium Exposure surge
suppression systems — the reliable way to
keep these power problems from getting
into your facility in the first place.
Liebert PowerSure®Panel TVSS Technical Specifications
Low Exposure Medium Exposure
Connection Type Parallel Parallel
Operating Voltage Range ±15% ±15%
Surge Current Capacity 25kA, 50kA or 100kA 100kA or 160kA
Fault Current Rating (AIC) 14kAIC 65kAIC
Dimensions 4.72"x4.72"x2.36" (160 kA units) 8"x6"x4"
(100 kA units) 6"x4"x3"
Operating Frequency Range 47–63 Hz 47–63 Hz
Capacity Continuous Continuous
EMI/RFI Attenuation 40 dB typical 40 dB typical
Response Time <0.5 nanoseconds <0.5 nanoseconds
Dry Contract rating 125 VAC, 8.0A, 1.0pf 125 VAC, 8.0A, 1.0pf
Operating Temperature -40°C to +50°C -40°C to +50°C
Operating Humidity 0% to 95% 0% to 95%
Status Indication LED, Dry Contacts LEDs, Dry Contacts
Certifications UL 1449, CUL(CE-optional) UL 1449, CUL
Warranty 5-Years 5-Years
UL 1449 (second edition) Classification
Low Exposure Medium Exposure
120 Volt systems 400 Volts all modes 400 Volts all modes
208 through 277 Volt systems 800 Volts all modes 800 Volts all modes
480 Volt systems 1,500 Volts all modes 1,500 Volts all modes
Ordering Information
Building a Low and Medium Exposure Model Number:
Examples
LP L 123 (Low Exposure Unit)
LP M 1 2 3 (Medium Exposure Unit)
Surge Current Capacity Model ID
(Low Exposure)
100 kA/Phase 100
(L-N: 50 kA + L-G: 50 kA; N-G: 50 kA)
50 kA/Phase 50
(L-N: 25 kA + L-G: 25 kA; N-G: 25 kA)
25 kA/Phase25-2
(L-N: 25 kA; N-G: 25 kA)
(Medium Exposure)
160 kA/Phase160
(L-N: 80 kA + L-G: 80 kA; N-G: 80 kA)
100 kA/Phase 100-2
(L-N: 100 kA; N-G: 100 kA)
System Configuration Model ID
Single (2 Wire + Gnd) N or L
Split (3 Wire + Gnd) S
Wye (4 Wire + Gnd) Y
Delta Hi-Leg (4 Wire + Gnd) H
Delta (3 Wire + Gnd) D
Nominal Voltage Requirements Model ID
L-N L-L L-G
120 N/A 120 120
120 208 120 120
120 240 240 120
N/A 208 208 208
230 400 230 230
N/A 240 240 240
277 480 277 277
N/A 400 400 400
N/A 480 480 480
(use Model ID column when
determining 1, 2, 3 portion
of Model Number)
{
1 3
2
Emerson Network Power.com
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity™.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
Liebert Corporation
1050 Dearborn Drive
P.O. Box 29186
Columbus, Ohio 43229
800 877 9222 Phone (U.S. &
Canada Only)
614 888 0246 Phone (Outside U.S.)
614 841 6022 FAX
Via Leonardo Da Vinci 8
Zona Industriale Tognana
35028 Piove Di Sacco (PD)
Italy
39 049 9719 111 Phone
39 049 5841 257 FAX
Emerson Network Power Asia Pacific
7/F., Dah Sing Financial Centre
108 Gloucester Rd, Wanchai
Hong Kong
852 25722201 Phone
852 28029250 FAX
liebert.com
Technical Support
800 288 6169 Toll-Free
607 724 2484 Phone
607 722 8713 Fax
While every precaution has been taken to ensure accuracy and
completeness in this literature, Liebert Corporation assumes no
responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions.
© 2008 Liebert Corporation. All rights reserved throughout
the world. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks
of their respective owners.
® Liebert is a registered trademark of the Liebert Corporation.
SL-22034 (R06/08) Printed in USA
Business-Critical Continuity™, Emerson Network
Power and the Emerson Network Power logo are
trademarks and service marks of Emerson
Electric Co. ©2008 Emerson Electric Co.
800 288 6169 Toll-Free
607 721 8865 Phone
607 722 8713 Fax