
393800‐2Rev1:02.058.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.noPage11
SupplyandExtractairshouldhavethesame
valueastheMAXvalueunder4.5.1.3(Setto
100%fromfactory.)
Evenifitisinstalledan"active"kitchen
ventilatorwithpipingnotconnectedtowards
theunit,theKVplugmustgetthesignalto
seethatkitchenventilatorisactivated.This
canbedonebyusingaapressureswitchin
theexhausttubefromtheventilator.Then
Extractsetdowntoaround50%orlessto
compensatefortheextractairinthehood.
Note!IfKVsignalplugisnotinusefor
cookerhoodthenyoucanusethesignaltoget
moresupplyairwhentofireupafireplace.
Thenadjustsothatsupplyairdeliversmore
airthanextractairfan.Inthiscaseyoumust
useaswitchandnotimpulseswitch.
4.5.1.6Externalarm
Iftheunithasbeenconnectedtoanexternal
humiditysensorormotionsensor.UsetheD2
connectorontopoftheunit.(Seepage23in
thismanual).Note!Inorderforthisfeatureto
work,youneedtheone‐poleswitchmarked
RH%ON/OFFinsidetheunittobesetin
position1.(Seepage2ofthismanualforthe
locationofthisswitch).
SupplyandExtractairshouldhavethesame
valueastheMAXvalueunder4.5.1.3(Setto
100%fromfactory.)
4.5.1.7Absent
Menuforsettingthedesiredvaluesby
activatingaway/homefunction.
UsetheD3connectorontopoftheunit.(See
page23inthismanual)Functionisoperated
viaanexternalswitch.
Setvalueofthedesiredtemperaturewill
showinthedisplayafteractivatingthe
function.
4.5.1.8Calibration
Menureadingofembeddedtemperature
sensors.
Thesetemperaturesensorsare
deliveredcalibratedfromthe
manufacturerandshouldnotbeattempted
changeinhere.
The«Outsideair»sensornormally
shows3‐6°Chightertemperaature
thenthereeloutsidetemperature.Thisisdue
toheatingoftheairintheductnetworkfrom
theintakegrilletotheintakeoftheunit
wherethesensorareplaced.