READ THIS FIRST:
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not,
contact the outlet where you bought this product.
This product contains glass, care must be taken when
assembling, tting or handling to prevent personal
injury or damage to the product.
This light tting must be installed by a competent
person in accordance with the Building Regulations
making reference to the current edition of the
IEE Wiring Regulations (BS7671). The Building
Regulations may be obtained from HMSO or viewed
and downloaded from www.communities.gov.uk
following the link for Building Regulations.
As the buyer, installer and/or user of this product it
is your own responsibility to ensure that this tting
is t for the purpose for which you have intended
it. Eterna Lighting cannot accept any liability for
loss, damage or premature failure resulting from
inappropriate use.
The lamps (bulbs/tubes) supplied with this tting are
consumable parts and therefore may be outside of
any warranty oered.
Switch o the mains before commencing installation
and remove the appropriate circuit fuse.
When working at heights, please use a suitable
platform.
Disconnect the tting from the electrical supply
before ash or high voltage testing.
Suitable for outdoor use.
This product is suitable for installation on surfaces
with normal ammability e.g. wood, plasterboard,
and masonry. It is not suitable for use on highly
ammable surfaces (e.g. polystyrene, textiles).
Before making xing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables.
The chosen location of your new tting should allow
for the product to be securely mounted and safely
connected to the mains supply (lighting circuit).
When choosing the location for your new tting,
ensure that the xings will be anchored in a solid
surface e.g. concrete, brick or a joist—do not x
directly onto panelling, cladding, plasterboard etc.
If the location of your new tting requires the
provision of a new electrical supply, the supply
must conform with the requirements of the Building
Regulations making reference to the current edition
of the IEE Wiring Regulations (BS7671).
This product is designed for permanent connection
to xed wiring: this should be either a suitable
lighting circuit (protected with a 5 or 6 Amp MCB or
fuse) or a fused spur (with a 3 Amp fuse) via a fused
connection unit.
We recommend that the supply incorporates a
switch for ease of operation.
Make connections to the electrical supply in
accordance with the following code:
Live - Brown or Red
Neutral - Blue or Black
Earth - Green and Yellow
When making connections, ensure that the terminals
are tightened securely and that no strands of wire
protrude. Check that the terminals are tightened
onto the bared conductors and not onto any
insulation.
This product must be connected to Earth.
IMPORTANT: Always switch o at the mains before
changing the lamp.
You are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation
there are electrical tests that should be carried out:
these tests are specied in the Wiring Regulations
(BS7671) referred to in the Building Regulations
CLEANING:
Disconnect the power and clean the exterior only of
this tting with a moist (not wet) cloth.
Do not use any chemical or abrasive cleaners.
EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Directive” eective August 2005—UK
WEEE Regulations eective 2nd January 2007).
Environment Agency Registered Producer: WEE/
GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF
ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE
RECYCLE IT WHERE FACILITIES EXIST DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return
it to the place where you bought it. Our Technical
Team will gladly advise on any Eterna Lighting
product, but may not be able to give specic
instructions regarding individual installations.
For breakage information visit:
www.eterna-lighting.co.uk
INSTALLATION:
01. Choose the location for your new oodlight
giving consideration to the points above.
02. Remove the bracket from the light by removing
the screws and nuts on each side.
03. Fix the bracket to the mounting surface using a
spirit level (if available) to ensure that the bracket
is xed level and using appropriate xings (not
supplied).
04. Attach the light tting to the bracket using the
screws, washers and nuts you removed earlier.
05. Rotate the tting in the bracket so that the light
faces directly downwards, this will give you easy
access to the connection box from above.
06. Remove the cover from the connection box by
removing the four screws and lifting o.
07. Remove the gland nut from the side of the
connection box and thread your supply cable
through.
08. Remove the rubber gland from the cable entry on
the side of the connection box and thread onto
the cable.
09. Thread the supply cable into the connection box
and make the connections according to the
colour code listed opposite and observing the
terminal identication markings inside the
connection box.
10. Push the rubber gland and nut back along the
cable until they locate in the threaded cable entry
and tighten the nut suciently to grip the cable
and make the entry water-tight.
Do not over-tighten.
11. Replace the connection box cover and replace the
four screws. Ensure that the sealing gasket is
correctly positioned.
12. Adjust the position of the light so that it
illuminates the desired area and limiting the
spread of light onto neighbouring property.
13. Tighten the bracket xing screws on the side of
the tting to lock in position.
14. Undo the screw at the top of the glass safety
shield on the front of the light tting and allow to
hang from the hinge.
15. Carefully remove the lamp from the box taking
care not to touch it with bare hands.
16. Using a soft, dry, clean cloth, grip the lamp
and t it between the sprung contacts in the
lampholder.
17. Close the glass safety shield and tighten the
screw. Ensure that the waterproong gasket in
correctly positioned.
18. Restore the power and switch on.
SPECIFICATION:
Weatherproof: IP44
Class 1 Protection: Class 1 / Earthed
LAMP REPLACEMENT:
01. Switch o the electricity at the mains.
02. Allow to cool down then undo the screw at the
top of the glass safety shield and allow to hang
down on the hinge.
03. Remove and replace lamp making sure it is of
the same type and wattage as stated on the re
lamping label, do not touch with bare ngers,
grip the lamp with a tissue or clean soft cloth.
04. Replace the glass safety shield and tighten
the retaining screw. Ensure that the gasket is
positioned correctly.
05. Restore the power and switch on.
REPLACEMENT LAMP TYPE:
ETH120L / ETH120LWH: requires 120W R7s linear
halogen (Eterna code: LH120).
ETH400L / ETH400LWH: requires 400W R7s linear
halogen (Eterna code: LH400).