General Information, Safety and Installation Instructions
Introduction
Your new floodlight incorporates a PIR (Passive Infra
Red) sensing device which is sensitive to movement
of warm objects within a preset operating zone and
immediately switches the light on when movement is
detected.
This makes this fitting ideal for automatically
illuminating pathways, steps, patios, porches, or
whatever area you have selected to light for reasons
of safety, convenience or security. While there is
movement within range of the unit the light will
remain on.
Read this first
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not, contact
the outlet where you bought this product.
This product contains glass, care must be taken when
assembling, fitting or handling to prevent personal
injury or damage to the product.
This light fitting must be installed by a competent
person in accordance with the Building Regulations
making reference to the current edition of the IEE
Wiring Regulations (BS7671). The Building Regulations
may be obtained from HMSO or viewed and
downloaded from www.communities.gov.uk following
the link for Building Regulations.
As the buyer, installer and/or user of this product it is
your own responsibility to ensure that this fitting is fit
for the purpose for which you have intended it. Eterna
Lighting cannot accept any liability for loss, damage or
premature failure resulting from inappropriate use.
If in any doubt, consult a qualified electrician.
The lamps (bulbs/tubes) supplied with this fitting are
consumable parts and therefore may be outside of any
warranty offered.
Switch off the mains before commencing installation
and remove the appropriate circuit fuse.
When working at heights, please use a suitable
platform.
Disconnect the fitting from the electrical supply before
flash or high voltage testing.
Suitable for indoor and outdoor use.
This product is suitable for installation on surfaces
with normal flammability e.g. wood, plasterboard, and
masonry. It is not suitable for use on highly flammable
surfaces (e.g. polystyrene, textiles).
Before making fixing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables.
The chosen location of your new fitting should allow
for the product to be securely mounted and safely
connected to the mains supply (lighting circuit).
When choosing the location for your new fitting,
ensure that the fixings will be anchored in a solid
surface e.g. concrete, brick or a joist—do not fix directly
onto panelling, cladding, plasterboard etc.
If the location of your new fitting requires the provision
of a new electrical supply, the supply must conform
with the requirements of the Building Regulations
making reference to the current edition of the IEE
Wiring Regulations (BS7671).
This product is designed for permanent connection to
fixed wiring: this should be either a suitable lighting
circuit (protected with a 5 or 6 Amp MCB or fuse) or a
fused spur (with a 3 Amp fuse) via a fused connection
unit.
We recommend that the supply incorporates a switch
for ease of operation.
Make connections to the electrical supply in
accordance with the following code:
Live - Brown or Red
Neutral - Blue or Black
Earth - Green and Yellow
When making connections, ensure that the terminals
are tightened securely and that no strands of wire
protrude. Check that the terminals are tightened onto
the bared conductors and not onto any insulation.
This product must be connected to Earth.
IMPORTANT - Always switch off at the mains before
changing the lamp.
Do not mount on a surface that is likely to vibrate.
For maximum detection area, the light should be
mounted 1.8 to 2.5 meters (6 to 8ft) above the
detection area (refer Fig.1A). The floodlight scanning
specifications (approximately 12 meters at 180°) may
vary slightly depending on the mounting height and
location.